Sony CFD-980 Service Manual page 20

Hide thumbs Also See for CFD-980:
Table of Contents

Advertisement

QQ
3 7 63 1515 0
Good Example
Incorrent Examples (DC level changes more than on adjusted
waveform)
low focus gain
high focus gain
TE
L 13942296513
5.
Connect the oscilloscope between TP (TE) and TP (VC).
Insert disc (YEDS-18) and press the CD ^ button.
6.
7.
Adjust RV704 so that the waveform is as shown in the figure
below. (tracking gain adjustment)
Incorrect Examples (fundamental wave appears)
www
.
http://www.xiaoyu163.com
VOLT/DIV : 20mV
TIME/DIV : 1ms
25mV
0V
VOLT/DIV : 20mV
TIME/DIV : 2ms
50mV
0V
VOLT/DIV : 100mV
TIME/DIV : 2ms
10mV
0V
VOLT/DIV : 0.1V
TIME/DIV : 2ms
0V
x
ao
u163
y
i
— 20 —
http://www.xiaoyu163.com
2 9
8
low tracking gain
high tracking gain
(high fandametial wave than for low gain)
[MAIN BOARD] (Component side)
Q Q
3
6 7
1 3
1 5
TP(TO)
TP(VC)
TP(FO)
co
.
9 4
2 8
VOLT/DIV : 0.1V
TIME/DIV : 2ms
0V
VOLT/DIV : 0.1V
TIME/DIV : 2ms
0V
0 5
8
2 9
9 4
2 8
Osillloscope
(DC range)
+
TP(VC)
m
9 9
9 9