kENDALL GENIUS 2 Operation And Service Manual

Infrared tympanic electronic thermometer

Advertisement

kENDALL
GENIUS
Infrared Tympanic Electronic Thermometer
Operation and Service Manual
Thermomètre électronique infrarouge auriculaire
Manuel d'utilisation et d'entretien
Elektronisches Infrarot-Ohrthermometer
Gebrauchs- und Wartungsanweisung
Termometro elettronico timpanico a infrarossi
Manuale operativo e di assistenza
Termómetro timpánico electrónico infrarrojo
Manual de operación y servicio
Infraröd elektronisk örontermometer
Användar- och servicemanual
Infrarode tympane elektronische thermometer
Handleiding voor bediening en onderhoud
Termómetro Auricular Electrónico por Infra-Vermelhos
Manual de funcionamento e assistência
Tympaaninen sähkökäyttöinen infrapunalämpömittari
Käyttö- ja huolto-opas
Infrarødt, elektronisk, tympanisk termometer
Betjenings- og servicehåndbog
Ηλεκτρονικό θερμόμετρο υπερύθρων τυμπάνου
Εγχειρίδιο λειτουργίας και συντήρησης
Infračervený bubínkový elektronický teploměr
Uživatelská a servisní příručka
Infravörös, timpanikus, elektronikus hõmérõ
Kezelési és karbantartási kézikönyv
Инфракрасный электронный термометр для
измерения тимпанической температуры
Руководство по эксплуатации и
техническому обслуживанию
Elektroniczny termometr bębenkowy na podczerwień
Instrukcja obsługi i serwisowania
Kızılötesi Timpanik Elektronik Termometre
Kullanım ve Servis Kılavuzu
Infrarødt, elektronisk øretermometer
Bruker- og vedlikeholdshåndbok
2
'
'entretien
� �
� �
������
����

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GENIUS 2 and is the answer not in the manual?

Questions and answers

Summary of Contents for kENDALL GENIUS 2

  • Page 1 ™ GENIUS Infrared Tympanic Electronic Thermometer Operation and Service Manual Thermomètre électronique infrarouge auriculaire – Manuel d’utilisation et d’entretien ’entretien ’ Elektronisches Infrarot-Ohrthermometer – Gebrauchs- und Wartungsanweisung Termometro elettronico timpanico a infrarossi – Manuale operativo e di assistenza Termómetro timpánico electrónico infrarrojo �...
  • Page 2: Table Of Contents

    English Table of Contents Page Section I — Introduction................1 Initial Set Up .
  • Page 3: Section I - Introduction

    • If using the wall or cart mount options (sold separately) for the base unit, consult the installation sheet provided with the respective system. • When first used, the GENIUS 2 Thermometer will show the factory preset settings: ear mode (EAR) and the celsius scale (°C).
  • Page 4: Section Iv - Icon Identification

    • When not in use, the GENIUS 2 Thermometer should be placed in the thermometer base unit. • The GENIUS 2 Thermometer should not be used on patients with ear drainage, blood, cerebrospinal fluid, vernix, ear wax plugs, or foreign bodies in the ear canal.
  • Page 5: Section V - Instructions For Use

    Kendall is not supported or sanctioned by Tyco Healthcare/Kendall. The use of unauthorized GENIUS 2 Thermometer probe covers could jeopardize the accuracy of the GENIUS 2 Thermometer. Check your probe cover carton for the ACCUSYSTEM√ logo to be certain that your thermometer will deliver an accurate temperature every time it is utilized.
  • Page 6: Probe Covers

    The GENIUS 2 Thermometer utilizes a single use disposable probe cover during temperature measurement. The probe cover was designed especially for use with the GENIUS 2 Thermometer. The use of probe covers produced by any company except Tyco Healthcare/Kendall will result in erroneous temperature measurement. In order to aid in infection prevention and control, always install a new probe cover prior to taking a temperature.
  • Page 7: Temperature Recall

    When a temperature is in the display, the user may press and hold the °C/°F button to toggle between degrees Celsius and degrees Fahrenheit. Sleep Mode The GENIUS 2 Thermometer enters sleep mode after 30-40 seconds of non-use. To wake up the thermometer, eject the attached probe cover and/or install a new probe cover. This energy conserving function optimizes battery life.
  • Page 8: Pulse Timer Mode

    Pulse Timer Mode 1. Press and hold the timer button to enter Timer mode. Press again to start the timer. The timer will run from 0 to 60 seconds. 2. The thermometer will issue a single beep at 15 seconds, a dual beep at 30 seconds, a triple beep at 45 seconds, and four beeps at 60 seconds. 3.
  • Page 9: Biotech Mode

    If the display shows a system error 4 and the system error icon, the ambient conditions are changing too rapidly for the device to be used. Allow the device to equilibrate for 20 minutes before using. If the display shows any other system error, then reset the thermometer by installing a probe cover. If the system error does not clear, then contact the factory for available service options.
  • Page 10 Temperature mode ������� � � � ������� �������������� �� ���������� �� ���������� �� �������������� �� Site mode ������� � � � ������� � ���� ��� � ����� ���� � ��������� �� � ������ ��� ��� ��� ™ Infrared Tympanic Electronic Thermometer GENIUS...
  • Page 11: Section Vi - Preventative Maintenance

    CaviWipes™* cleansing agents is acceptable. However, prolonged or repeated use of these chemicals may result in damage to the thermometer case and display area. • Use of a cloth or sponge is recommended for cleaning. Never use an abrasive pad or an abrasive cleaner on the GENIUS 2 Thermometer. ENIUS 2 Thermometer.
  • Page 12: Section X - Troubleshooting

    Engineering department or contact the factory for available service options. The service information is located in Section XII, Customer Service The GENIUS 2 Thermometer advisory and alarm conditions are described in the Thermometer Display Icons and Alarms subheading of Section V, Instructions for Use Section XI — Specifications Clinical accuracy characteristics and procedures are available from the manufacturer on request To verify accuracy, use a certified blackbody as specified in EN 12470-5-2003, Annex C or use a Genius 2 Checker/Calibrator –...
  • Page 13: Battery Life

    -25°C to 55°C (-13°F to 131°F), up to 95% RH non-condensing. If the unit is stored at extremes, it is recommended that the unit be checked on the field calibration checker or at the factory before returning to service Clinical Repeatability: Meets Section A.5 of EN 12470-5: 2003 (E) per Tyco Healthcare/Kendall technical report. Data is available from Tyco Healthcare/Kendall on request. Response Time:...
  • Page 14: Section Xii - Customer Service

    The GENIUS 2 Thermometer follows international regulatory standards • EN 12470-5:2003 (E) Clinical Thermometers – Part 5: Performance of infrared ear thermometers where sections 6.3.4 and 6.5.5 were met based on Tyco Healthcare/Kendall technical report. Data is available from Tyco Healthcare/Kendall on request •...
  • Page 15: Section Xiii - Warranty

    (1) year from the date of original purchase from Tyco Healthcare/Kendall or its authorized distributor. If this product does not operate as warranted above during the applicable...
  • Page 16 GENIUS ™ 2 English kENDALL ™ GENIUS Infrared Tympanic Electronic Thermometer Operation and Service Manual Thermomètre électronique infrarouge auriculaire – Manuel d’utilisation et d’entretien Elektronisches Infrarot-Ohrthermometer – Gebrauchs- und Wartungsanweisung Termometro elettronico timpanico a infrarossi – Manuale operativo e di assistenza ™...

Table of Contents