GIGA-TMS PROMAG TR610 User Manual

Hide thumbs Also See for PROMAG TR610:

Advertisement

Quick Links

Produkt dostpny w sklepie www.Soyter.pl <--- kliknij
TR610 User's Manual
© 2008 GIGA-TMS Inc.
All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying,
recording, taping, or information storage and retrieval systems - without the written permission of the publisher.
Products that are referred to in this document may be either trademarks and/or registered trademarks of the respective owners. The publisher and the
author make no claim to these trademarks.
While every precaution has been taken in the preparation of this document, the publisher and the author assume no responsibility for errors or
omissions, or for damages resulting from the use of information contained in this document or from the use of programs and source code that may
accompany it. In no event shall the publisher and the author be liable for any loss of profit or any other commercial damage caused or alleged to have
been caused directly or indirectly by this document.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROMAG TR610 and is the answer not in the manual?

Questions and answers

Summary of Contents for GIGA-TMS PROMAG TR610

  • Page 1 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij TR610 User's Manual © 2008 GIGA-TMS Inc. All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems - without the written permission of the publisher.
  • Page 2: Table Of Contents

    2 Changing the TR610's Functionality ........................... 51 3 Uploading New Firmware ........................... 52 4 Event Log File Format ........................... 56 5 I/O Connector Pin Assignment & Cable Wiring ........................... 57 6 Specifications ........................... 59 7 Update History ........................... 60 © 2008 GIGA-TMS Inc.
  • Page 3 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij Part...
  • Page 4 · Based on RFID (Proximity) technology · 10/100 Base-T Ethernet port · RS232 serial port for connecting external serial devices (such as a barcode scanner) · Two relays to control external loads, such as an electric bell and a turnstile © 2008 GIGA-TMS Inc.
  • Page 5: Part I Introduction

    · Built-in Web server for administration and event log download · IP address configuration using DHCP · Time/Date synchronization through SNTP (time-zone can be preset) · Works with Tibbo AggreGate · Internal application written in Tibbo BASIC and may be changed or customized © 2008 GIGA-TMS Inc.
  • Page 6 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij Part...
  • Page 7: Part Ii Getting Started

    - Shows how to set up time synchronization with a time server. Working in the Normal Mode - Provides an overview of normal use of the device. You can let your users read this topic if they have any questions about operating the terminal. © 2008 GIGA-TMS Inc.
  • Page 8: Hardware Installation

    · Two screw anchors (for drilling into the wall) · CD containing manual 2. If mounting on a wall: Drive the two provided mounting screws into the wall, 9.5cm apart, using the provided screw anchors as needed. These should fit the terminal's mounting holes: © 2008 GIGA-TMS Inc.
  • Page 9 Note! The top does not come off. It is connected via a ribbon cable - it only flips up. 5. With the terminal open, locate the Ethernet and power connectors: © 2008 GIGA-TMS Inc.
  • Page 10 Assignment & Cable Wiring in the Reference section. 6. Now route the cables into the terminal and connect them (Ethernet and power). If mounting on a wall: There are two possible ways to route cables into the terminal: © 2008 GIGA-TMS Inc.
  • Page 11 If mounting on a desk: Usually method B should be used (unless you wish to route the cables through the actual surface of the desk by making a hole). 7. Once the cables are routed properly into the terminal and connected, close the top cover and re- insert the screws. © 2008 GIGA-TMS Inc.
  • Page 12: Powering Up For The First Time

    When you connect the TR610 to a power source for the first time, the following sequence of screens will be shown: Logo Screen The first screen displays the GIGA-TMS logo and the current version of the internal application. This screen is shown every time the device boots, not only on the first time. Information Screen This screen provides an overview of basic device settings, as follows: ON: Owner Name.
  • Page 13 If you do lose the card, you would have to initialize the terminal. Now hit any of the terminal's four buttons, and you will soon see the Normal Mode screen. The next thing to do is to set the terminal's IP address © 2008 GIGA-TMS Inc.
  • Page 14: Configuring Ip, Gateway & Netmask

    The device will now reboot. Watch the information screen closely: DHCP should say ENABLED and then the IP address of the device will be displayed. Manual Configuration Sometimes, DHCP does not work or is not configured. In such a case, the settings need to be manually configured: © 2008 GIGA-TMS Inc.
  • Page 15 Internet Explorer, etc) and enter the terminal's IP address in the navigation bar. You should get the Web-Based Setup screen. The next thing to do would be configuring automatic time synchronization (or just setting the correct time, if synchronization is not needed). © 2008 GIGA-TMS Inc.
  • Page 16: Time Synchronization

    5. Select Y (yes) and watch the screen. If all goes well, time sync should work now. If it fails for some reason, re-check your network settings and Time Server address. Configuring Auto-Sync Auto-sync allows the TR610 to connect to the timeserver once a day, and re-set its internal clock so that the time is always accurate. © 2008 GIGA-TMS Inc.
  • Page 17 2. Set the current date. The system for entering numbers and strings using the on-screen setup is described here 3. Go to Setup > Date/Time > Set Time. 4. Set the current time, in 24-hour format ("military time"). © 2008 GIGA-TMS Inc.
  • Page 18: Working In The Normal Mode

    2. Scan your card. The terminal will beep and display the card number: A new record would be added to the event log. This would happen for all cards, except for the Master Card you designated before. Scanning this card would take you to the on-screen setup menu © 2008 GIGA-TMS Inc.
  • Page 19 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij Part...
  • Page 20: Part Iii Administration

    AggreGate Integration - Explains how to connect the TR610 to AggreGate LinkServer. Programming Priorities - Shows what happens when a programming session is started when another session is already in progress. © 2008 GIGA-TMS Inc.
  • Page 21: Web-Based Setup And Administration

    Once you've accessed the terminal's IP address, you should get the following screen: By default, the password is admin (you can change it after you log in). Once you log in, you'll see the administration interface: © 2008 GIGA-TMS Inc.
  • Page 22 This is the same information as appears in the Information Screen on device startup On-Screen Information When a Web-admin session is in progress, a small H (for HTTP) is displayed at the lower-left corner of the TR610 screen: © 2008 GIGA-TMS Inc.
  • Page 23: General Settings

    Mounting Method: This is the orientation of the device (Desktop or Wall). It controls the direction of text on the display. Once you have changed the settings as required, click Save. To make the settings apply, you must reboot the device. © 2008 GIGA-TMS Inc.
  • Page 24: Network Settings

    , and also for accessing the AggreGate server, in case it is outside the current network segment. Netmask: This is the netmask for the network on which the terminal is installed. Once you have changed the settings as needed, click Save. To apply the settings, reboot device. © 2008 GIGA-TMS Inc.
  • Page 25: Aggregate Settings

    Web Admin. Note that the password is not hidden either in the Web Admin nor in the On-Screen menu. Once you have changed the settings as needed, click Save. To apply the settings, reboot device. © 2008 GIGA-TMS Inc.
  • Page 26: Date/Time Settings

    The Event Log page lets you browse and filter the events accumulated by the terminal. Event Filter The Event Filter section lets you search the internal event log by date, event, and user ID. By default, it is empty, so everything is shown. © 2008 GIGA-TMS Inc.
  • Page 27 Reset Criteria (button): Clears all criteria fields. Event Log The lower part of the Event Log screen displays event log records (either a complete listing, or a search result, as determined by the Filter above). The most recent entries are presented first. © 2008 GIGA-TMS Inc.
  • Page 28: Initialize

    Bottom: Go to the end (oldest page) of the log or search results. 3.1.6 Initialize When selecting Initialize from the main Web Administration menu, the following confirmation dialog is displayed: © 2008 GIGA-TMS Inc.
  • Page 29: Reboot

    Note that log out may also occur automatically, after a certain period of inactivity. This is a security feature, meant to prevent unauthorized tampering with TR610 configuration. You will also be logged out if anyone logs onto the device's on-screen setup menu (see © 2008 GIGA-TMS Inc.
  • Page 30 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij TR610 User's Manual Configuration Priorities © 2008 GIGA-TMS Inc.
  • Page 31: On-Screen Setup And Administration

    -- Mounting Method Network Network Settings DHCP Network Settings -- DHCP IP address Network Settings -- IP address Gateway IP Network Settings -- Gateway IP Netmask Network Settings -- Netmask AggreGate AggreGate Settings Enable/Disable AggreGate Settings -- Enable/Disable © 2008 GIGA-TMS Inc.
  • Page 32: Text Entry

    Thus, a system for entering text and numbers using the device's four hardware buttons has been developed: Button Function Top-left, quick push Move to next character position Top-left, push and hold Move to previous character position Bottom-left, quick push Enter next character (a, then b, then c, etc) © 2008 GIGA-TMS Inc.
  • Page 33 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij Administration Bottom-left, push and hold Enter previous character (c, then b, then a) Top-right Abort (exit without saving string) Bottom-right Save string and exit © 2008 GIGA-TMS Inc.
  • Page 34: Aggregate Integration

    Device Server Auto Registration. This setting allows LinkServer to listen for new devices and let them login automatically. 6. Within Client, right-click your username and select Edit User Properties: © 2008 GIGA-TMS Inc.
  • Page 35 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij Administration 7. In the User Properties dialog, make sure Enable Automatic Registration of Device Servers (the last setting in the dialog) is checked. © 2008 GIGA-TMS Inc.
  • Page 36 AggreGate > Server IP and enter the IP of your LinkServer. For help entering text strings using the on-screen menu, see here 10. Now go to Server Port and make sure it is 6450 (default, unless you changed it on the server for some reason). © 2008 GIGA-TMS Inc.
  • Page 37 12. Go to Enable/Disable and select Enabled. 13. Now set the proper Owner Name. Owner Name should be the same as your LinkServer username (default is admin). Go to Setup > General > Owner Name and enter your LinkServer username. © 2008 GIGA-TMS Inc.
  • Page 38 AggreGate, test the IP address, subnet mask and gateway settings, and the AggreGate-specific settings. 17.Run AggreGate Client and you should see your TR610 (with the name you selected) in the system tree: © 2008 GIGA-TMS Inc.
  • Page 39 Now that the device appears to be connected, let's test it by creating an event filter to show all users logging in or out using the TR610. 1. Go to Event Filters, right-click and select Create New Filter. 2. By default, the Filter Data table is full of criteria we don't need right now. © 2008 GIGA-TMS Inc.
  • Page 40 Next, you have to specify a Context Mask to which the filter should apply. Rather than typing the mask in manually, click the "..." button. 5. This pops up a selection tree. Navigate as shown below (to the device.agent - not just device. Then click OK. © 2008 GIGA-TMS Inc.
  • Page 41 6. It is now time to specify the event name to be filtered. Let's filter all Card Read events: 7. That's it. Save the filter by clicking 8. Now pop up the event log and scan a card on the TR610. It should show up immediately. © 2008 GIGA-TMS Inc.
  • Page 42 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij TR610 User's Manual © 2008 GIGA-TMS Inc.
  • Page 43: Configuration Priorities

    TR610 LCD: Selecting Y will "kick" the Web user out and allow you to use the on-screen interface. 2. Web Interface: Configuration using the Web interface has the second priority level. While a Web © 2008 GIGA-TMS Inc.
  • Page 44 The TR610 display shows the letter A in the lower-left corner when the terminal is connected to AggreGate, and the letter H (for HTTP) when a Web Admin session is in progress: Connected to AggreGate. Web admin session is in progress. © 2008 GIGA-TMS Inc.
  • Page 45 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij Administration © 2008 GIGA-TMS Inc.
  • Page 46 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij Part...
  • Page 47: Part Iv Reference

    - Explains the structure of the event log file, for importing into time and attendance software. I/O Connector Pin Assignment & Cable Wiring - Shows all connectors and their pinouts. Specifications - Device hardware specifications. Update History - History of changes since initial release of TR610 manual. © 2008 GIGA-TMS Inc.
  • Page 48: Initializing The Device

    3. Hit the lower-right (Enter) button. You will get a confirmation prompt. 4. Hit the top-right (Y) button. 5. The device will now initialize and reboot. 6. Upon rebooting, the device will show the Master Card registration screen: © 2008 GIGA-TMS Inc.
  • Page 49 This is a hardware-based method you can use if you lose the Master Card and also are unable to access the Web Administration interface. 1. Open up the TR610. 2. Inside, there are two small buttons: RST (left) and MD (right). © 2008 GIGA-TMS Inc.
  • Page 50 3. Push the MD button for three seconds. The LED pattern near the button should change. Now release the button. 4. The device will now reboot and show the Master Card registration screen * The device could also be initialized using TIDE, but this falls beyond the scope of this manual. © 2008 GIGA-TMS Inc.
  • Page 51: Changing The Tr610'S Functionality

    The TR610 firmware is open-source, and is written in Tibbo BASIC, so it's easy to understand. You can download the firmware source files and modify them using readily-available development tools. Sounds interesting? Click here for more information. © 2008 GIGA-TMS Inc.
  • Page 52: Uploading New Firmware

    TR610 open - you will need to press a button inside the device later on. 4. Run DS Manager, switch to the Serial Access tab and click the COM port to which the TR610 is connected: © 2008 GIGA-TMS Inc.
  • Page 53 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij Reference 5. Click the Upgrade button. The following dialog will be shown. Click Browse and select the firmware file you wish to upload. 6. Click OK. The following dialog will be shown: © 2008 GIGA-TMS Inc.
  • Page 54 Now let go of the RST button and leave MD pressed. The device will boot with MD pressed, which will put it into firmware upgrade mode. After a moment, the following progress dialog will be shown, and you can let go of the MD button. © 2008 GIGA-TMS Inc.
  • Page 55 9. Upon completion of the process, the following dialog will be shown: 10. Now press the RST button again. The TR610 should boot up using the new firmware. At this point, initializing the device is recommended. © 2008 GIGA-TMS Inc.
  • Page 56: Event Log File Format

    Each record begins with a NULL character due to internal memory management (the NULL character is used as a marker by the TR610). The character may be removed on the computer once the file has been downloaded. © 2008 GIGA-TMS Inc.
  • Page 57: O Connector Pin Assignment & Cable Wiring

    Produkt dostpny w sklepie www.Soyter.pl <--- kliknij Reference I/O Connector Pin Assignment & Cable Wiring The following diagram shows the user-serviceable parts of the TR610 PCB. These are the pinouts for all internal connectors on the TR610: © 2008 GIGA-TMS Inc.
  • Page 58 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij TR610 User's Manual © 2008 GIGA-TMS Inc.
  • Page 59: Specifications

    Internal Application: Upgradeable, open-source, written in Tibbo BASIC Mounting: Wall or desktop (programmable display orientation) Power supply: DC 12V, 500mA Operating Temperature: 0-55 degree C Operating Humidity: 10-90% * Depends on the size of the loaded Tibbo BASIC application © 2008 GIGA-TMS Inc.
  • Page 60: Update History

    Produkt dostpny w sklepie www.Soyter.pl <--- kliknij TR610 User's Manual Update History 24 November 2008: Initial release of manual. © 2008 GIGA-TMS Inc.

Table of Contents