Kenwood MDX-F1 Service Manual page 14

Md personal stereo system
Hide thumbs Also See for MDX-F1:
Table of Contents

Advertisement

MDX-F1
When the FF(¡)button in remote controller is pressed while the setting is displayed, the setting increases,
and a new setting is stored in RAM.
When the FB(1)button in remote controller is pressed while the setting is displayed, the setting increases,
and a new setting is stored in RAM.
When the FF or FB button in remote controller is pressed continously, steps is change by 100ms period.
If the measurement value is within the OK range, "
7. MANUAL adjustment mode
High reflection disc
Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the MD REC button 7 times.
Step 3
Press once the MD PLAY button. Initial setting
Step 4
Press once the MD REC button.
Step 5
Press once the MD REC button.
Step 6
Press once the MD REC button.
Step 7
Press once the MD REC button.
Step 8
Press once the MD REC button.
Step 9
Press once the MD REC button.
If the MD STOP button is pressed while the MANUAL adjustment menu is displayed, the state is changed to the TEST mode STOP
state.
Low reflection disc
Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the MD REC button 7 times.
Press once the MD PLAY button. Initial setting → Temperature measuring mode
Step 3
Step 4
Press once the MD REC button.
Step 5
Press once the MD REC button.
Step 6
Press once the MD REC button.
Step 7
Press once the MD REC button.
Step 8
Press once the MD REC button.
Step 9
Press once the MD REC button.
Step 10
Press once the MD REC button.
Step 11
Press once the MD REC button.
Step 12
Press once the MD REC button.
Step 13
Press once the MD REC button.
Step 14
Press once the MD REC button.
Step 15
Press once the MD REC button.
If the MD STOP button is pressed twice while the MANUAL adjustment menu is displayed, the state is changed to the TEST mode
STOP state.
8. TEST-PLAY mode
Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the TAPE REC button.
Step 3
Press once the MD PLAY button. During search the search output is set to "H", and it is
Continuous playback (groove section) (Address + C1 error indication)
Step 4
Press once the MD STOP button. TEST-PLAY menu
Step 5
If the MD STOP button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
If the MD PLAY button is pressed while the TEST-PLAY menu is displayed, continuous playback is started from the current pickup position.
: Adress,
14
CIRCUIT DESCRIPTION
" appears on the 8th character.
MANUAL adjustment menu
Laser ON
Innermost periphery move
Tracking ATT (F signal) setting
Indication of tracking EFMIO measurement
Focus ATT (A signal) setting
Focus ATT (B signal) setting
MANUAL adjustment menu
Laser ON
Innermost periphery move → Tracking ATT (E signal) setting
Tracking ATT (F signal) setting
Indication of tracking EFMIO measurement (pit section)
Focus ATT (A signal) setting
Focus ATT (B signal) setting
Outside periphery move → Track closs setting
Tracking ATT (E signal) setting
Tracking ATT (F signal) setting
Indication of tracking EFMIO measurement (groove section)
Focus ATT (A signal) setting
Focus ATT (B signal) setting
TEST-PLAY menu
returned to "L" when continuous playback is started.
: Error late
Remarks
Temperature measuring mode
Tracking ATT (E signal) setting
Remarks
Remarks
Display
[ t s m
e
]
[ _ M N U _ A J S T _ ]
[ T M P : _
_ _ _ ]
[ L O N : _ _ _ _ _ _ ]
[ P E G :
]
[ P F G :
]
[ P M I :
_ _ _ ]
[ H A G :
]
[ H B G :
]
Display
[ t s m
e
]
[ _ M N U _ A J S T _ ]
[ T M P : _
_ _ _ ]
[ L O N : _ _ _ _ _ _ ]
[ P E G :
]
[ P F G :
]
[ P M I :
_ _ _ ]
[ L A g :
]
[ L B g :
]
[ G C G :
]
[ G E G :
]
[ P F G :
]
[ G M I :
_ _ _ ]
[ L A G :
]
[ L B G :
]
Display
[ t s m
e
]
[ T E S T _ P L A Y _ ]
[a
c
]
[ T E S T _ P L A Y _ ]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents