MDX-F1
3. AUTO FAB adjusting mode
Step No.
Setting Method
Step 1
T est mode STOP state
Step 2
Press the MD REC button three times
Step 3
Press the MD PLAY button 1 time
Step 4
Press the MD STOP button
Step 5
¥
: measurement value
value
¥ If the STOP button is pressed while the AUTO FAB adjustment is displayed, the state is change to the TEST mode STOP
state.
¥ If the STOP button is pressed while the automatic adjustment is displayed, the state is change to the AUTO FAB
adjustment state.
4. RESULT sub-mode
Step No.
Setting Method
Step 1
Test mode STOP state
Step 2
Press the MD REC button 4 times.
Step 3
Press once the MD PLAY button. Indication of measurement value
Step 4
Press once the MD REC button.
Step 5
Press once the MD REC button.
Step 6
Press once the MD REC button.
Step 7
Press once the MD REC button.
Step 8
Press once the MD REC button.
Step 9
Press once the MD REC button.
Step 10
Press once the MD REC button.
Step 11
Press once the MD REC button.
Step 12
Press once the MD REC button.
Step 13
Press once the MD REC button.
Step 14
Press once the MD REC button.
Step 15
Press once the MD REC button.
Step 16
Press once the MD REC button.
Step 17
Press once the MD REC button.
Step 18
Press once the MD REC button.
Step 19
Press once the MD REC button.
Step 20
Press once the MD REC button.
Step 21
Press once the MD REC button.
Step 22
Press once the MD REC button.
Step 23
Press once the MD REC button.
Step 24
Press once the MD REC button.
Step 25
Press once the MD STOP button. RESULT sub-menu state
: Measurement value,
When the FF(¡)button in remote controller is pressed while the setting is displayed, the setting increases,
and a new setting is stored in RAM.
When the FB(1)button in remote controller is pressed while the setting is displayed, the setting increases,
and a new setting is stored in RAM.
When the FF or FB button in remote controller is pressed continously, steps is change by 100ms period.
12
CIRCUIT DESCRIPTION
AUTO FAB adjustment menu
End of automatic adj.
High reflection disc
AUTO FAB adjustment menu, step 2
Message output for 1 sec.
Adjustment menu(high reflection disc)
: FAB value in measurement,
RESULT sub-menu
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of adjustment error sequence No.
Indication of adjustment status
Indication of pre-adjustment not completed (00)/completed (4B)
: Adjustment value,
: Other various informations
Remarks
step 4
step 5
AUTO FAB.
: C1 error value in measurement,
Remarks
Display
[_AUT_FAB_ _]
: FAB
Display
[ t s m
e
]
[ _ R S T _ Y O B I _ ]
[ R F G : _
_ _
_ _
]
[ R C G : _
_ _
_ _
]
[ R T G : _ _ _ _ _
]
[ G T G : _ _ _ _ _
]
[ P C H : _ _ _ _
]
[ G C H : _ _ _ _
]
[ S A G : _ _ _
]
[ S B G : _ _ _
]
[ S E G : _ _ _
]
[ S F G : _ _ _
]
[ H A O :
_ _ _]
[ H B O :
_ _ _]
[ H E O :
_ _ _]
[ H F O :
_ _ _]
[ L A O :
_ _ _]
[ L B O :
_ _ _]
[ L E O :
_ _ _]
[ L F O :
_ _ _]
[ T C O : _
_ _ _]
[ Y O B : _
_ _ _]
[ D I F : _
_ _ _]
[ A D J : _
_ _ _]
[ _ R S T _ Y O B I _ ]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents