  • Page 1 P600 ioProx Long Range Proximity Reader Installation Manual DN5084-0804...
  • Page 2 Copyright © 2008 Tyco International Ltd. and its Respective Companies. All Rights Reserved. All specifications were current as of publication date and are subject to change without notice.
  • Page 3: Safety Instructions

    Safety Instructions The P600 ioProx Long Range Reader is designed to be INSTALLED and MAINTAINED by SERVICE PERSONNEL ONLY. Service personnel must have appropriate technical training and experience necessary to be aware of the hazards to which they are exposed and of measures to minimize the danger to themselves or other persons.
  • Page 4 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
  • Page 5: Table Of Contents

    P600 ioProx Long Range Reader Installation Manual Table of Contents System Overview ....................7 Specifications ......................... 7 Operations ........................8 Installing the P600 Proximity Long Range Reader ..........9 Opening the Enclosure ....................9 Setting the Data Format ....................10 Installing the Strain Relief and Connecting Cables ............
  • Page 6 Installation Manual P600 ioProx Long Range Reader DN5084-0804...
  • Page 7: System Overview

    AWG cable. The P600 Long Range Proximity Reader can be powered from 12VDC to 28VDC. A bi-color LED and audible tone provide user feedback. A single dipswitch gives field configuration for Kantech Extended Secure Format (XSF) or 26-bit Wiegand data output format.
  • Page 8: Operations

    Kantech XSF or Wiegand. If the reader is set to 26-bit Wiegand, it sounds four beeps and the LED flashes three times. If it is set to Kantech XSF format, it sounds two beeps and the LED flashes two times.
  • Page 9: Installing The P600 Proximity Long Range Reader

    The P600 can be mounted and installed in seven easy steps: 1. Opening the enclosure, 2. Setting the required data format (Kantech XSF or 26-bit Wiegand), 3. Installing the strain relief and connecting the cable, 4. Mounting the reader to its location, 5.
  • Page 10: Setting The Data Format

    The Kantech XSF is the default format. To set the data format: 1. To select the Kantech XSF format, set the communication mode dipswitch to XSF (lower position, toward the board edge side). 2. To select the 26-bit Wiegand format, set the dipswitch to Wiegand26 (upper position, toward the board components).
  • Page 11: Installing The Strain Relief And Connecting Cables

    P600 ioProx Long Range Proximity Reader Installation Manual 2.3 Installing the Strain Relief and Connecting Cables The strain relief serves as a cable fitting. You can use either 18 AWG or 22 AWG wires. The cable does not need to be shielded and/or pair twisted. However, it is strongly recommended to use an 18 AWG non-shielded 6-wire cable such as BELDEN 5304UE and 8-wire cable such as BELDEN 5306UE.
  • Page 12 Installation Manual P600 ioProx Long Range Proximity Reader DN5084-0804...
  • Page 13: Mounting The P600

    P600 ioProx Long Range Proximity Reader Installation Manual Chapter 3 • Mounting the P600 Mount the base of the P600 that holds the electronics to the surface using the holes located on the base of the reader. There are holes corresponding to each type of installation. No drilling is required for most installation types, except for installation on an electrical post (refer to “Installing the P600 on an Electrical Post”...
  • Page 14: Installing The P600 On A Wall

    Installation Manual P600 ioProx Long Range Proximity Reader 3.1 Installing the P600 on a Wall Wall mounting is preferably done onto a flat surface. There are 14 well distributed holes for easy installation on a wall. Caution! If you are mounting the reader on a brick wall, care should be taken not to force the screws in a manner to curve the casing.
  • Page 15: Installing The P600 On A Gooseneck

    P600 ioProx Long Range Proximity Reader Installation Manual In order to install the U-bolts, you will need to drill a 5/16” (8mm) hole using the pre-positioned holes. Depending on the U-bolt used you may need to cut the length of it in order to meet the inside case room.
  • Page 16: Weatherproofing The P600

    Installation Manual P600 ioProx Long Range Proximity Reader The next figure shows to install the P600 on a gooseneck (holes marked “D”). Figure 3.3 - Goose neck installation 3.5 Weatherproofing the P600 A proper sealing of the reader ensures weatherproofing. The P600 is a sealed equipment but some holes will be created at installation time giving openings allowing water to enter.
  • Page 17: Wiring The P600

    4.1 Wiring Perform the following steps to complete wiring: 1. Install the KT-PC4204 as per the recommendations (Kantech Installation Instructions DN1246). Note that the KT-PC4204 is strictly used as a power supply and no other equipment except the transformer and the battery should be connected to it. Do not power it up yet.
  • Page 18: Closing The Enclosure

    Installation Manual P600 ioProx Long Range Proximity Reader 3. Connect the negative side of the power supply from P600 GROUND to the KT-PC4204 GND. 4. Connect the positive supply from P600 SUPPLY to KT-PC4204 AUX. 5. Wire jump KT-PC4204 AUX to KT-PC4204 RED. 6.
  • Page 19: Testing

    Installation Manual 4.4 Testing Test for read range with a valid Kantech proximity card (P10 SHL). It is important to understand that the Host must be configured in order to accept the data from the reader. If the reader does not work properly, refer to “Troubleshooting”...
  • Page 20 Installation Manual P600 ioProx Long Range Proximity Reader DN5084-0804...
  • Page 21: Installation Notes And Guidelines

    P600 ioProx Long Range Proximity Reader Installation Manual Chapter 5 • Installation Notes and Guidelines Various factors may affect the read range of the P600: • Installation near metal, • Radio frequency interference, • Transponder type. The following sections will enable you to find solutions should the read range of the P600 be reduced.
  • Page 22: Radio Frequency Interference

    Do not mount the P600 within 15 feet (5 m) of any monitors (VDTs or CRTs). 5.4 Transponder Type The type of transponder used affects the read range of the P600. The various styles of KANTECH cards and transponders use different types of antennas. The antenna type will determine the read range for that type of transponder.
  • Page 23: Troubleshooting

    P600 ioProx Long Range Proximity Reader Installation Manual Troubleshooting Warning! Troubleshooting should be performed by qualified service personnel only. Before calling the Technical support, verify the following: Reader doesn’t read 1. Verify that no other proximity cards are in the reading field (up to 36 inches (91 cm) from the reader).
  • Page 24 Installation Manual P600 ioProx Long Range Proximity Reader 4. The LED must turn green when connecting the “BRN” or LED terminal to the reader’s ground. If not, return the reader. Reader BUZZER doesn’t sound 1. Verify that the “blue” wire or Buzzer terminal is connected to the door controller's output. 2.
  • Page 26 Tel: +1(450) 444-2030 • Toll Free: US & Canada: +1 888 222-1560 • Fax: +1(450) 444-2029 www.kantech.com kantechsupport@tycoint.com Copyright © 2008 Tyco International Ltd. and its Respective Companies. All Rights Reserved. All specifications were current as of publication date and are subject to change without notice.