Page 4
(2) this device must accept any interference received including interference that may cause undesired operation. This class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. The P345MTR and P345KPMTR readers are also compliant with EN55022:1998, amendment 1:1995, Class A. DN1870-0905...
Page 5
To be used with UL Listed Access Control Units as indicated in the control unit’s installation instructions. For this product, the HID KSF (Kantech Secure Format) and ioProx Kantech XSF have not been evaluated by UL. UL has not evaluated the RS-485 Output of this reader.
Page 6
ETSI EN300 330-2: Electromagnetic Compatibility and Radio • Spectrum Matters (ERM); Short Range Devices (SRD); Radio Equipment in the Frequency Range 9 kHz to 25 MHz and Inductive Loop Systems in the Frequency Range 9 kHz to 30 MHz; Part 2: Harmonized EN under Article 3.2 of the R&TTE Directive.
P345MTR and P345KPMTR Readers Installation Manual Introduction The P345MTR Contactless readers will read Prox and Smart Cards at frequencies of both 125 kHz and 13.56 MHz. The reading capability includes, for Smart Cards, both unencrypted serial numbers and encrypted MIFARE® programmed sectors.
Integrated reader tamper protection. Mounting Mount the single-gang backplate (with tamper magnet installed) onto the wall. Figure 1: P345MTR Reader Backplate with Tamper Switch Magnet Note: Mounting holes fit standard U.S. single-width electrical box and standard European (EMEA) electrical box hole patterns.
Page 9
P345MTR and P345KPMTR Readers Installation Manual Figure 2: Mounting Assembly with Isolation Spacer (Optional) Please note that Figure 2 shows the P345MTR reader and cover plate. Although the P345KPMTR keypad reader and front cover plate differ, the mounting assembly is the same as the P345MTR.
1.8 cm (2 tamper plates) 0.9 cm (1 tamper plate) 0 cm Installation of two P345MTR readers side-by-side and back-to- back Read range is not affected if the center-to-center distance between two readers is greater than or equal to four (4) inches (101.6 mm). Two readers can simultaneously read the same badge or tag if the distance between the two readers is less than 4 inches, center-to-center.
P345MTR and P345KPMTR Readers Installation Manual Wiring P345MTR models have twelve terminals as noted in Table 3. The terminal strip is removable for easy installation and wiring. When attaching wires to the connector, strip off only the minimum insulation required (approx. 1/8'') and push the wire into the connector until the insulation is flush or inside the connector body.
The ground line of the local power supply must be connected to the power supply of the controller. Figure 3: Wiring Examples to Kantech Controllers The unit needs to be operated with a power source with limited power consumption according to EN 60950-1 (2003) paragraph 2.5.
P345MTR and P345KPMTR Readers Installation Manual Troubleshooting If the operation of a component is in doubt, substitute a known good component and retry the system. Always verify wiring against the provided wiring information before powering up the reader. Table 5: Error Conditions and Possible Solutions...
Deister SmartFrame® in both 125 kHz and 13.56 MHz implementations Other Standards HID Prox at 125 kHz (All Formats) Compliance HID KSF (Kantech Secure Format) ioProx Kantech XSF PIN Code Entry Keys Twelve PIN code entry keys 0-9, Command/Enter, (Model P345KPMTR only)
Page 15
P345MTR and P345KPMTR Readers Installation Manual 1 to 5 in. (2.5 to 12.7 cm) depending on credential technology and environment. Note: Read range for credentials of identical Read Range technologies may vary greatly depending on the tuning and antenna structure of each individual credential.