Kantech P345MTR Installation Manual

Kantech P345MTR Installation Manual

Multi-technology 125 khz and 13.56 mhz readers

Advertisement

P345MTR and P345KPMTR
Multi-Technology
125 KHz and 13.56 MHz Readers
Installation Manual
DN1870-0905

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P345MTR and is the answer not in the manual?

Questions and answers

Summary of Contents for Kantech P345MTR

  • Page 1 P345MTR and P345KPMTR Multi-Technology 125 KHz and 13.56 MHz Readers Installation Manual DN1870-0905...
  • Page 2: Table Of Contents

    P345MTR and P345KPMTR Readers Installation Manual Table of Contents Introduction ................... 5 Features ..................6 Mounting ..................6 Installation Considerations ............8 Wiring .................... 9 Installation Notes ................. 10 Troubleshooting ................11 Technical Specifications .............. 12 DN1870-0905...
  • Page 3: Technical Support

    Copyright © 2009 Tyco International Ltd. and its Respective Companies. All Rights Reserved. All specifications were current as of publication date and are subject to change without notice. Kantech and the Kantech logo are trademarks of Tyco International Ltd. and its Respective Companies.
  • Page 4 (2) this device must accept any interference received including interference that may cause undesired operation. This class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. The P345MTR and P345KPMTR readers are also compliant with EN55022:1998, amendment 1:1995, Class A. DN1870-0905...
  • Page 5 To be used with UL Listed Access Control Units as indicated in the control unit’s installation instructions. For this product, the HID KSF (Kantech Secure Format) and ioProx Kantech XSF have not been evaluated by UL. UL has not evaluated the RS-485 Output of this reader.
  • Page 6 ETSI EN300 330-2: Electromagnetic Compatibility and Radio • Spectrum Matters (ERM); Short Range Devices (SRD); Radio Equipment in the Frequency Range 9 kHz to 25 MHz and Inductive Loop Systems in the Frequency Range 9 kHz to 30 MHz; Part 2: Harmonized EN under Article 3.2 of the R&TTE Directive.
  • Page 7: Introduction

    P345MTR and P345KPMTR Readers Installation Manual Introduction The P345MTR Contactless readers will read Prox and Smart Cards at frequencies of both 125 kHz and 13.56 MHz. The reading capability includes, for Smart Cards, both unencrypted serial numbers and encrypted MIFARE® programmed sectors.
  • Page 8: Features

    Integrated reader tamper protection. Mounting Mount the single-gang backplate (with tamper magnet installed) onto the wall. Figure 1: P345MTR Reader Backplate with Tamper Switch Magnet Note: Mounting holes fit standard U.S. single-width electrical box and standard European (EMEA) electrical box hole patterns.
  • Page 9 P345MTR and P345KPMTR Readers Installation Manual Figure 2: Mounting Assembly with Isolation Spacer (Optional) Please note that Figure 2 shows the P345MTR reader and cover plate. Although the P345KPMTR keypad reader and front cover plate differ, the mounting assembly is the same as the P345MTR.
  • Page 10: Installation Considerations

    1.8 cm (2 tamper plates) 0.9 cm (1 tamper plate) 0 cm Installation of two P345MTR readers side-by-side and back-to- back Read range is not affected if the center-to-center distance between two readers is greater than or equal to four (4) inches (101.6 mm). Two readers can simultaneously read the same badge or tag if the distance between the two readers is less than 4 inches, center-to-center.
  • Page 11: Wiring

    P345MTR and P345KPMTR Readers Installation Manual Wiring P345MTR models have twelve terminals as noted in Table 3. The terminal strip is removable for easy installation and wiring. When attaching wires to the connector, strip off only the minimum insulation required (approx. 1/8'') and push the wire into the connector until the insulation is flush or inside the connector body.
  • Page 12: Installation Notes

    The ground line of the local power supply must be connected to the power supply of the controller. Figure 3: Wiring Examples to Kantech Controllers The unit needs to be operated with a power source with limited power consumption according to EN 60950-1 (2003) paragraph 2.5.
  • Page 13: Troubleshooting

    P345MTR and P345KPMTR Readers Installation Manual Troubleshooting If the operation of a component is in doubt, substitute a known good component and retry the system. Always verify wiring against the provided wiring information before powering up the reader. Table 5: Error Conditions and Possible Solutions...
  • Page 14: Technical Specifications

    Deister SmartFrame® in both 125 kHz and 13.56 MHz implementations Other Standards HID Prox at 125 kHz (All Formats) Compliance HID KSF (Kantech Secure Format) ioProx Kantech XSF PIN Code Entry Keys Twelve PIN code entry keys 0-9, Command/Enter, (Model P345KPMTR only)
  • Page 15 P345MTR and P345KPMTR Readers Installation Manual 1 to 5 in. (2.5 to 12.7 cm) depending on credential technology and environment. Note: Read range for credentials of identical Read Range technologies may vary greatly depending on the tuning and antenna structure of each individual credential.
  • Page 16 Copyright © 2009 Tyco International Ltd. and its Respective Companies. All Rights Reserved. www.kantech.com DN1870-0905...