Isotech 96178 User Maintenance Manual/Handbook

High temperature standard platinium resistance thermometer

Advertisement

Quick Links

HIGH TEMPERATURE
STANDARD PLATINIUM
RESISTANCE THERMOMETER
MODEL 96178
User Maintenance Manual/Handbook
Isothermal Technology Limited, Pine Grove, Southport, PR9 9AG, England
Tel: +44 (0)1704 543830 Fax: +44 (0)1704 544799 Internet: www.isotech.co.uk E-mail: info@isotech.co.uk
The company is always willing to give technical advice and assistance where appropriate. Equally, because of the programme of continual
development and improvement we reserve the right to amend or alter characteristics and design without prior notice. This publication is for
information only
Page 1 of 12
HTSPRT Model 96178 Iss.06 – 03/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 96178 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Isotech 96178

  • Page 1 Isothermal Technology Limited, Pine Grove, Southport, PR9 9AG, England Tel: +44 (0)1704 543830 Fax: +44 (0)1704 544799 Internet: www.isotech.co.uk E-mail: info@isotech.co.uk The company is always willing to give technical advice and assistance where appropriate. Equally, because of the programme of continual development and improvement we reserve the right to amend or alter characteristics and design without prior notice.
  • Page 2: Table Of Contents

    ACCURACY OF MEASUREMENT ............................... 11 REPRODUCIBILITY OF MEASUREMENTS ..........................11 UNCERTAINTY OF MEASUREMENT ............................11 STABILITY..................................... 11 DRIFT ......................................11 PACKING INSTRUCTIONS FOR THE RETURN OF YOUR 96178 ....................12 Page 2 of 12 HTSPRT Model 96178 Iss.06 – 03/11...
  • Page 3: Guarantee

    INTERFERENCE WITH OR FAILURE TO PROPERLY MAINTAIN THIS INSTRUMENT MAY INVALIDATE THIS GUARANTEE RECOMMENDATION The life of your ISOTECH Instrument will be prolonged if regular maintenance and cleaning to remove general dust and debris is carried out. ISOTHERMAL TECHNOLOGY LTD.
  • Page 4: Operating Instructions

    You or your company has just paid a considerable sum of money to purchase this 96178. Although the materials to make the 96178 are very costly, it has also taken up to 1000 hours to prepare the 96178 for your use.
  • Page 5: Preparing The Box

    Place the protective sheath if supplied on top of the chips and seal the box. Always remember to label the box thoroughly with “fragile” and “this way up” labels and arrange adequate insurance cover. Your unit should now be ready to send. Page 5 of 12 HTSPRT Model 96178 Iss.06 – 03/11...
  • Page 6: Stability Evaluation

    1000 C and being 0.25 ohms at 0 C. Its main radical and new features are: The 96178 can be supplied pre-sealed with an inert gas containing 10% oxygen or with a valve built into the handle so the user can allow the thermometer to breath.
  • Page 7: Results

    High temperature thermometers take a long while - many hundred, if not thousands of hours - to stabilise completely. Thermometer 962/148 is some 3 to 4 years old and has proved to be our most stable thermometer. 96178/1 was stabilised only overnight after its arrival from manufacture; even so the stability of the new thermometer is remarkable.
  • Page 8: Conclusion

    CONCLUSION The 96178/1 thermometer has shown itself to be as stable as our very best standard thermometer after only an overnight anneal. FURTHER WORK As more thermometers are produced and tested further reports will be issued to confirm the results above.
  • Page 9 Page 9 of 12 HTSPRT Model 96178 Iss.06 – 03/11...
  • Page 10 Page 10 of 12 HTSPRT Model 96178 Iss.06 – 03/11...
  • Page 11: Glossary Of Metrological Terms

    The ability of a measuring instrument to maintain constant its metrological characteristics. DRIFT The slow variation with time of metrological characteristic of a measuring instrument. *Measurand = a quantity subjected to measurement Page 11 of 12 HTSPRT Model 96178 Iss.06 – 03/11...
  • Page 12: Packing Instructions For The Return Of Your 96178

    PACKING INSTRUCTIONS FOR THE RETURN OF YOUR 96178 Page 12 of 12 HTSPRT Model 96178 Iss.06 – 03/11...