Peltor Lite-Com Pro II Product Range
MT7H7F4010-EU-50 with headband
MT7H7B4010-EU-50 with neckband
MT7H7P3E4010-EU-50 with helmet attachment for Peltor G22 and G3000 hardhats.
(A rear plate is also included for helmet attachments for the Peltor G2000 hardhat.)
Technical Data
Frequency range:
FCC:462.5625MHz~467.7125MHz,
406.1 - 430,440 - 470MHz,LPD:433.05 - 434.79 MHz(Note:LPD only used in Europe)
CE:PMR
Operation mode:
Simplex
Channels:
Max. 30
Channel raster:
Channel separation:
FCC/IC: 12.5 kHz CE: 12.5 kHz/ 25 kHz
Modulation:
(FM)
FCC/IC: 2.5 kHz
CE: 2.5 kHz/ 5kHz
FM (16K0F3E / 8K50F3E)
Microphone type:
Electret (MT53) or dynamic (MT7)
Receiver sensibility:
Typical -122 dBm
Selective squelch:
Programmable (and supports CTCSS and DCS)
Output power:
200 / 20 / 10 mW ERP
Range:
Outdoors up to 3 km depending on conditions
Power consumption:
Stand-by: ca 55 mA
Receiving: ca 65 mA
Transmission:
Low power:
ca 100 mA
Medium power:
ca 115 mA
High power:
ca 200 mA
Operating time at conditions
10/10/80 TX/RX/Standby at 20°C:
Hi output power:
ca 14 hours
Mid output power:
ca 16 hours
Low output power:
ca 17 hours
Operating temperature:
-20°C to +55°C
Storage temperature:
-40°C to +55°C
Weights including ACK08 battery:
MT7H7F4010-**-50:
540 g
MT7H7B4010-**-50:
500 g
MT7H7P3E4010-**-50: 540 g
ACK08 technical information
Charging time:
approx. 10-12 hours (no visible charging indicators for ACK08)
Capacity:
3,7 V, 1350 mA, 5 Wh
Charging cable:
AL2AH (fused 200mA)
After charging cycle is finished charger automatically turns into maintenance charging mode.
ACK08 must be charged with AL2AH connected to a certified 5V SELV power supply such as 3M, Peltor battery charger
FR08. Power supply must be able to deliver a minimum of 200 mA.
3M Occupational Health &
Environmental Safety Division
© 3M 2012. All rights reserved.
3M Svenska AB, Box 2341
3M™ Peltor™ Lite-Com™ Pro is made in Sweden by
SE-331 02 Värnamo
3M Svenska AB, SE-331 02, Värnamo, Sweden.
Sweden
Phone: +46 (0) 370 65 65 65
3M, Peltor and Peltor Lite-Com are trademarks of 3M Corporation,
Fax: +46 (0) 370 65 65 99
St. Paul, MN 55144-1000, USA
Email: peltorcommunications@mmm.com
Internet: www.3M.com/Peltorcomms
Please recycle. Printed in Sweden.
Peltor
Lite-Com
Pro II
™
™
The Sound Solution
MT7H7F4010-EU-50
MT7H7B4010-EU-50
MT7H7P3E4010-EU-50
403 – 470 MHz
Quick reference guide
Key
Function
MODE
Switches the Lite-Com Pro II on and off.
Choose between the functions in the menu.
UP (+)
Increases the level of the selected function.
DOWN (–)
Decreases the level of the selected function.
PTT
Transmits with the Lite-Com Pro II.
E)
Attenuation (with head band)
Frequency (Hz)
125
250
500
1000
2000
4000
8000
H
M
Mean attenuation (dB)
14.7
23.4
30.7
34.6
34.5
36.9
37.3
St. dev. (dB)
3.9
4.6
3.2
3.4
3.1
2.7
4.2
33 dB
27 dB
APValue (84%)
10.8
18.8
27.4
31.2
31.4
34.2
33.1
Attenuation (with neck band)
Frequency (Hz)
125
250
500
1000
2000
4000
8000
H
M
Mean attenuation (dB)
15.5
23.3
31.2
35.6
35.0
36.5
40.9
St. dev. (dB)
2.6
2.3
2.0
3.2
3.4
3.4
3.3
33 dB
29 dB
APValue (84%)
13.0
21.0
29.2
32.4
31.6
33.2
37.6
Attenuation (with helmet attachment)
Frequency (Hz)
125
250
500
1000
2000
4000
8000
H
M
Mean attenuation (dB)
16.2
22.9
31.7
35.6
34.5
37.7
40.0
St. dev. (dB)
3.2
2.2
2.0
2.9
3.0
3.9
3.3
33 dB
29 dB
APValue (84%)
13.0
20.7
29.7
32.7
31.5
33.8
36.8
Mean attenuation (dB) = Average attenuating characteristics at given frequency
St. dev. (dB) = Standard deviation at given frequency
APV (dB) = Assumed Protection Value. Average attenuating characteristics minus standard deviation at given frequency.
H = Average attenuation characteristics in the higher frquency spectrum
M = Average attenuation characteristics in the mid range frequency spectrum
L = Average attenuation characteristics in the higher frequency spectrum
SNR = Single Number Rating
MT53H7F470-50
MT53H7B470-50
MT53H7P3E470-50
L
SNR
19 dB
30 dB
L
SNR
21 dB
31 dB
L
SNR
21 dB
31 dB