Version Information Version Release Date Notes 02/17 Initial release AT-ETU-SYNC...
Page 3
Welcome to Atlona! Thank you for purchasing this Atlona product. We hope you enjoy it and will take a extra few moments to register your new purchase. Registration only takes a few minutes and protects this product against theft or loss. In addition, you will receive notifications of product updates and firmware.
Page 4
Atlona requires that products returned are properly packed, preferably in the original carton, for shipping. Cartons not bearing a return authorization or case number will be refused. Atlona, at its sole discretion, reserves the right to reject any products received without advanced authorization. Authorizations can be requested by calling 1-877-536-3976 (US toll free) or 1-408- 962-0515 (US/international) or via Atlona’s website at www.atlona.com.
Page 5
Damage, deterioration or malfunction resulting from the installation or removal of this product from any installation, any unauthorized tampering with this product, any repairs attempted by anyone unauthorized by Atlona to make such repairs, or any other cause which does not relate directly to a defect in materials and/or workmanship of this product.
Page 6
Where shielded interface cables have been provided with the product or specified additional components or accessories elsewhere defined to be used with the installation of the product, they must be used in order to ensure compliance with FCC regulations. AT-ETU-SYNC...
It is compatible with all video resolutions, audio formats, and color space formats supported in the HDMI 2.0a specification, plus the ability to pass metadata for HDR content. The Etude Sync includes Atlona’s award-winning 10-year limited product warranty and customer support services, so that integrators can specify, purchase, and install with confidence.
Refer to Performing System Tests (page Connect the included USB cable to this port. This for more information. port is used to power the AT-ETU-SYNC and to update firmware. As of this writing, no firmware TEST updates are available.
4. Connect the 5V DC power supply to an available AC outlet. Connection Diagram The illustration below, shows the proper location of the AT-ETU-SYNC in a basic source-sink setup. The location of the AT-ETU-SYNC will vary, depending on the system. Before using the AT-ETU-SYNC as an EDID emulator, an EDID must be selected or learned.
7. Power the sink device. 8. The source will use the selected EDID mode when sending audio/video data to the sink device. NOTE: The EDID dial can be set to any EDID mode, while the AT-ETU-SYNC is powered and connected to the system.
3. Rotate the EDID dial to EDID mode 0, as shown. EDID mode 0 4. Connect an HDMI cable from the sink device to the HDMI OUT port on the AT-ETU-SYNC. Make sure that the sink device is powered-on. AT-ETU-SYNC Display (Sink) 5.
Page 13
Sink device not detected. 7. Reconnect the source (or other intermediate device) to the HDMI IN port on the AT-ETU-SYNC. The source will read the EDID data stored in EDID mode 0 and use this information to send the proper audio and video formats to the sink device.
Basic Operation Performing System Tests The AT-ETU-SYNC features a TEST button which tests the source, sink, or the entire system to aid in troubleshooting connectivity issues. In-Line Testing 1. Power the AT-ETU-SYNC. 2. Position the AT-ETU-SYNC between the source and sink. The actual position of the AT-ETU-SYNC will depend upon the setup.
Page 15
Check that a source device is connected • Verify the integrity of the HDMI cable connected to the source device Solid red HDP is low. The AT-ETU-SYNC will generate the No sink device is detected • Check that a sink device is connected •...
Placing the AT-ETU-SYNC in-line, between the source and sink, will usually correct these issues. Experimenting with the position of the AT-ETU-SYNC, within the system - particularly when intermediate devices are installed - may be necessary to obtain the correct results. If the problem persists, contact an Atlona Technical Support Engineer for assistance.
Appendix EDID Modes The AT-ETU-SYNC comes with ten EDID modes. Mode 0 is used to record an external EDID and modes 1 through 9 are pre-programmed. The details for each EDID mode are listed below. EDID Mode Suppported Features No data until learned...
Page 18
720 x 576p at 50Hz - EDTV (16:9, 64:45) 720 x 480i at 60Hz - Doublescan (16:9, 32:27) 720 x 576i at 50Hz - Doublescan (16:9, 64:45) YCbCr 4:4:4, YCbCr 4:2:2 LPCM 2-channel, 16/20/24 bit depths at 44/48/96/192 kHz FL/FR AT-ETU-SYNC...
Page 19
60Hz - HDTV (16:9, 1:1) 1280 x 720p at 50Hz - HDTV (16:9, 1:1) 720 x 480p at 60Hz - EDTV (16:9, 32:27) 720 x 576p at 50Hz - EDTV (16:9, 64:45) 720 x 480i at 60Hz - Doublescan (16:9, 32:27) AT-ETU-SYNC...
Page 20
8-channel, 16/20/24 bit depths at 32/44/48/88/96/176/192 kHz AC-3 6-channel, 640k max. bit rate at 32/44/48 kHz 6-channel, 1536k max. bit rate at 44/48/88/96 kHz 8-channel at 44/48 kHz DVD-A 8-channel at 48/96/192 kHz DTS-HD 8-channel, 16-bit at 44/48/88/96/176/192 kHz FL/FR, FLFE, FC, RL/RR, RLC/RRC AT-ETU-SYNC...
1080p - Feet / Meters HDMI @ 60 Hz HDMI @ 24 Hz Signal Bandwidth 18 Gbps HDCP Temperature Fahrenheit Celsius Operating 32 to 122 0 to 50 Storage -4 to 140 -20 to 60 Humidity (RH) 20% to 90%, non-condensing AT-ETU-SYNC...
Page 22
Inches Millimeters H x W x D 1.02 x 4.29 x 3.50 26 x 109 x 89 H x W x D (w/ ears) 1.02 x 5.00 x 3.74 26 x 127 x 95 Weight Pounds Kilograms Device 0.27 AT-ETU-SYNC...