Page 1
CONTOUR MODEL 3290 - TEAK FINISH & SILHOUETTE MODEL 3291 - MAHOGANY FINISH MODEL 3297 - BLACK ASH FINISH RADIANT / CONVECTOR GAS FIRES INSTALLATION & SERVICING INSTRUCTIONS THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) AT A SUPPLY PRESSURE OF 20mbar (8in w.g.)
APPLIANCE DATA This appliance does contain not any component manufactured Burner injectors: from asbestos or asbestos related products. Upper (Centre radiant) Bray cat 28 size 120 The appliance data label is on the inner face of the metal case Lower (Outer radiants) Bray cat 28 size 250B at the left side.
Page 4
The space between the back of the outer case and the front face of the fireplace must not be filled in. Note: 2.3.2. The flue must serve only one fireplace. The Valor decorative cover plate is suitable for use. 2.3.3. Any damper or register plate should be removed. If 2.10.
affect the safe performance of the appliance. Note 2.12. In the United Kingdom No special ventilation bricks the spillage test requirements detailed further on in or vents are required in the room for this appliance. this manual. If the fan is likely to affect the appliance, In the Republic of Ireland permanent ventilation the appliance must not be installed unless the fan is must comply with the regulations currently in force.
3.4. FITTING THE CLOSURE PLATE 3.4.3 Wall mounting (Figure 7) (Figures 5,6 & 7) The closure plate must be fitted and sealed to the fireplace opening using a suitable heat resistant material. If necessary cut the closure plate. Leave the closure plate sufficiently large to overlap the fireplace opening by 25mm.
4. APPLIANCE INSTALLATION 4.1. INSTALLING TO A HEARTH 4.3. GAS SUPPLY CONNECTION 4.1.1. 4.3.1. Place the fire centrally on the hearth making sure An Rp1/4 (1/4in. B.S.P.) elbow connector is that the spigot lines up with the spigot hole in the provided.
extractor fan is installed in the same room as the FINAL ASSEMBLY appliance or a connecting room, check that spillage 5.3.1 Fit the bottom trim using the two knurled screws to does not occur with the fan operating and all doors secure it to the side feet (see figure 9) and other openings between the fan and the appliance open.
7. SERVICING & PARTS REPLACEMENT • Always turn off the gas supply and make sure that the 7.4. TO REMOVE THE BURNER, GAS appliance is cool before commencing any servicing. TAP & PILOT ASSEMBLY • Always test for gas soundness and spillage after servicing the 7.4.1.
7.7. TO GREASE THE GAS TAP 7.8. TO REMOVE THE COMPLETE FIRE 7.7.1. CHECK CHIMNEY Remove the gas tap complete with piezo generator - see section 7.5. DEBRIS. 7.7.2. Remove the two screws and shakeproof washers 7.8.1. Remove the outer case - see section 7.2. securing the piezo generator.