Valor 3290 Installation And Servicing

Radiant/convector gas fires
Hide thumbs Also See for 3290:

Advertisement

Quick Links

CONTOUR
MODEL 3290 - TEAK FINISH
&
SILHOUETTE
MODEL 3291 - MAHOGANY FINISH
MODEL 3297 - BLACK ASH FINISH
RADIANT / CONVECTOR GAS FIRES
INSTALLATION & SERVICING INSTRUCTIONS
THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) AT A
SUPPLY PRESSURE OF 20mbar (8in w.g.)
THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM (GB)
AND THE REPUBLIC OF IRELAND (IE) ONLY
INSTALLER: Please leave these instructions with the owner
600A591/04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3290 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Valor 3290

  • Page 1 CONTOUR MODEL 3290 - TEAK FINISH & SILHOUETTE MODEL 3291 - MAHOGANY FINISH MODEL 3297 - BLACK ASH FINISH RADIANT / CONVECTOR GAS FIRES INSTALLATION & SERVICING INSTRUCTIONS THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) AT A SUPPLY PRESSURE OF 20mbar (8in w.g.)
  • Page 2: Table Of Contents

    LIST OF CONTENTS Page Appliance dimensions Appliance data General installation requirements Unpacking & pre-installation preparation • Carton contents • Fireplace flue pull check • Preparing appliance for installation • Closure plate fitting Appliance installation • Hearth installation • Wall mounting •...
  • Page 3: Appliance Data

    APPLIANCE DATA This appliance does contain not any component manufactured Burner injectors: from asbestos or asbestos related products. Upper (Centre radiant) Bray cat 28 size 120 The appliance data label is on the inner face of the metal case Lower (Outer radiants) Bray cat 28 size 250B at the left side.
  • Page 4 The space between the back of the outer case and the front face of the fireplace must not be filled in. Note: 2.3.2. The flue must serve only one fireplace. The Valor decorative cover plate is suitable for use. 2.3.3. Any damper or register plate should be removed. If 2.10.
  • Page 5: Unpacking & Pre-Installation Preparation

    affect the safe performance of the appliance. Note 2.12. In the United Kingdom No special ventilation bricks the spillage test requirements detailed further on in or vents are required in the room for this appliance. this manual. If the fan is likely to affect the appliance, In the Republic of Ireland permanent ventilation the appliance must not be installed unless the fan is must comply with the regulations currently in force.
  • Page 6: Closure Plate Fitting

    3.4. FITTING THE CLOSURE PLATE 3.4.3 Wall mounting (Figure 7) (Figures 5,6 & 7) The closure plate must be fitted and sealed to the fireplace opening using a suitable heat resistant material. If necessary cut the closure plate. Leave the closure plate sufficiently large to overlap the fireplace opening by 25mm.
  • Page 7: Appliance Installation

    4. APPLIANCE INSTALLATION 4.1. INSTALLING TO A HEARTH 4.3. GAS SUPPLY CONNECTION 4.1.1. 4.3.1. Place the fire centrally on the hearth making sure An Rp1/4 (1/4in. B.S.P.) elbow connector is that the spigot lines up with the spigot hole in the provided.
  • Page 8: Final Assembly

    extractor fan is installed in the same room as the FINAL ASSEMBLY appliance or a connecting room, check that spillage 5.3.1 Fit the bottom trim using the two knurled screws to does not occur with the fan operating and all doors secure it to the side feet (see figure 9) and other openings between the fan and the appliance open.
  • Page 9: Servicing & Parts Replacement

    7. SERVICING & PARTS REPLACEMENT • Always turn off the gas supply and make sure that the 7.4. TO REMOVE THE BURNER, GAS appliance is cool before commencing any servicing. TAP & PILOT ASSEMBLY • Always test for gas soundness and spillage after servicing the 7.4.1.
  • Page 10: Gas Tap Greasing

    7.7. TO GREASE THE GAS TAP 7.8. TO REMOVE THE COMPLETE FIRE 7.7.1. CHECK CHIMNEY Remove the gas tap complete with piezo generator - see section 7.5. DEBRIS. 7.7.2. Remove the two screws and shakeproof washers 7.8.1. Remove the outer case - see section 7.2. securing the piezo generator.
  • Page 11 VALOR HEATING ERDINGTON, BIRMINGHAM B24 9QP Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. ©Valor Heating...

This manual is also suitable for:

32973291

Table of Contents