14 | Lap Trigger
14.3.2
14.3.3
134 / 160
Distance based retrigger protection
Trigger is locked until configured min distance (i.e. 80 % → 3200 m) of track dis‐
tance (i.e. 4000 m) has been covered. To deactivate distance based retrigger pro‐
tection, set min distance to 0 %.
Change signal for vehicle speed,
if desired.
Enter minimum speed for
trigger release.
Define settings for distance
based retrigger protection.
Define settings for distance
based forced trigger.
Main Trigger
Distance based forced trigger
After a missed main trigger, a forced trigger is inserted, if the configured max.
distance (i.e. 120 % → 4800 m) of the track distance (i.e. 4000 m) has been
reached. In this case, the channel 'Laptrigger_distlap_dls' starts at the delta be‐
tween the max. distance and the track distance (i.e. 800 m).
To deactivate distance based forced triggers, uncheck box.
Change signal for vehicle speed,
if desired.
Enter minimum speed for
trigger release.
Define settings for distance
based retrigger protection.
Define settings for distance
based forced trigger.
DDU 7 Manual
Trigger prohibited
Bosch Motorsport