Advertisement

Quick Links

User Manual for
Mendor SMART

Blood Glucose Meter

Model Name: GM01CAB
Manufacturer i-SENS, Inc. www.i-sens.com
43, Banpo-daero 28-gil, Seocho-gu, Seoul 06646,
Korea

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GM01CAB and is the answer not in the manual?

Questions and answers

Summary of Contents for MENDOR GM01CAB

  • Page 1: Blood Glucose Meter

    User Manual for Mendor SMART Blood Glucose Meter Model Name: GM01CAB Manufacturer i-SENS, Inc. www.i-sens.com 43, Banpo-daero 28-gil, Seocho-gu, Seoul 06646, Korea...
  • Page 2: Table Of Contents

    5 seconds with a small (0.5 μl) blood sample. Specifications....................7 Mendor SMART Blood Glucose Monitoring System Components....8 Mendor SMART Blood Glucose Meter is capable of sending test results to Warnings......................9 Mendor Balance server by using 3G data transmission. Mendor SMART Blood Mendor SMART Blood Glucose Meter Test Strip..........10...
  • Page 3: Information: Read This First

    • Milking of finger may affect result. ed errors in monitoring by using the no-coding function. • The Mendor SMART Blood Glucose Meter should be used only with the Mendor The following chart explains the symbols you will find in Mendor SMART Blood Test Strips.
  • Page 4: Important Information

    100.5 mm (height) x 48.0 mm (width) x 18.5 mm (thickness) Weight 59.1g (with battery) Operating ranges NOTE! If you need assistance with using the Mendor SMART Blood Glucose Temperature 5 - 50 °C (41-122 °F) Meter, please, contact the manufacturer. Relative humidity 10 - 90 %...
  • Page 5: Mendor Smart Blood Glucose Monitoring System Components

    Do not test while the battery is being charged. Additionally: Do not reuse test strips. • In order to to clean Mendor SMART Blood Glucose Meter you need 70% Do not use test strips past the expiration date. isopropyl alcohol available in local pharmacies.
  • Page 6: Mendor Smart Blood Glucose Meter Test Strip

    MENDOR SMART BLOOD GLUCOSE METER TEST STRIP MENDOR SMART BLOOD GLUCOSE METER The Mendor SMART Blood Glucose Meter Test Strip supports the accurate measurement of blood glucose levels in a capillary whole blood sample. Contact bars Meter Display Gently push the test strip,...
  • Page 7: Meter Display

    Messages sound and alarm. Provides Mendor Balance server Mendor SMART Blood Glucose Meter provides the blood glucose values in messages. 3 different colors (orange, blue and red) to indicate different blood glucose levels, as following: • Orange for measurements above 15 mmol/L (270 mg/dL) •...
  • Page 8 Insert the test strip with Date notation. contact bars facing upwards. Alarm Set up alarm. Network Switch connec- tion On / Off. Synchronize Synchronize meter with the Mendor Security Token Balance service. Retrieve Security Token for connecting the meter to Mendor Balance.
  • Page 9: Operating Mendor Smart Blood Glucose Meter

    BASIC SETTINGS Turn on Mendor SMART Blood Glucose Meter When using the Mendor SMART Blood Glucose Meter for the first time, please, check and update the meter’s settings prior to using the meter. You can start Mendor SMART Blood Glucose Setting up the Date and Time Meter by pressing the “...
  • Page 10: Basic Settings

    BASIC SETTINGS BASIC SETTINGS Step 3a: Auto Set mode Step 5: Setting the Time Format In Auto set mode, by pressing “Agree” button, the meter sets The meter provides two options for your convenience. automatically to the local time- You can choose from “12-Hour” or “24-Hour” option. zone.
  • Page 11: Setting Up The Audio Function

    BASIC SETTINGS BASIC SETTINGS Setting up the Audio function Setting up the Alarm Step 1: Setting the Sound (Beep) Step 1: Entering the Alarm settings Enter the Sound mode. In this mode, you can select from Alarm or Result Alarm. The meter provides 2 different sound options: On and Off.
  • Page 12: Network

    In this mode, you can see current alarm setting. Check Step 1: Enter the Network Settings marks indicates that “This alarm is activated.“ Mendor SMART Blood Glucose Meter provides up to 3 regular Enter the Network settings by moving the cursor to alarms.
  • Page 13: Synchronize

    BASIC SETTINGS BASIC SETTINGS Synchronize Security Token Step 1: Synchronizing the meter with Balance Step 1: Retrieving the Security Token When using the meter with Balance, the Synchronize Security Token is a code which is needed for connect- function can be used to upload measurements from the ing the meter to a Balance account.
  • Page 14: Checking The System

    CHECKING THE SYSTEM CONTROL SOLUTION TESTING History Checking with control solution You may check your meter and test strips using Mendor SMART Step 1 Blood Glucose Meter Control Solution, which contains a known Insert a test strip with contact bars facing upwards amount of glucose and is used to check that the meter and the into the strip port.
  • Page 15 • When the meter is not functioning properly Compare the result with the control solution range printed on the Mendor SMART Blood Glucose Meter Test Strip bag. The result should fall within that range. Used strips should be discarded safely in dis-...
  • Page 16: Testing Your Blood Glucose

    TESTING YOUR BLOOD GLUCOSE TESTING YOUR BLOOD GLUCOSE Small children (under the age of 10) and handicapped or invalid persons need to Applying Blood Sample be supervised when they use the equipment. Step 3 Preparing the Meter and Test Strip Obtain a blood sample using a lancing device.
  • Page 17: High And Low Message

    TESTING YOUR BLOOD GLUCOSE HIGH AND LOW MESSAGE Step 5 Mendor SMART Blood Glucose Meter displays test results between 1.1 - 33.3 mmol/L (20 - 600 mg/dL). Please refer to the instructions below, if you The test result (in mmol/L) will receive a High or Low message.
  • Page 18: Viewing Test Results In Mendor Smart Blood Glucose Meter'smemory

    MESSAGES MEMORY Step 1 Mendor SMART Blood Glucose Meter stores the last 500 glucose test results On the Message menu, with time and date. If the memory is full, the oldest test result will be replaced by you can see messages regard- new test results.
  • Page 19: Charging Mendor Smart Blood Glucose Meter

    Connect the end of the micro USB cable to the meter charging port. Then plug the Mendor SMART Blood Glucose Meter displays the battery status with 6 image other end of the cable to the USB port on your computer or other powered USB...
  • Page 20: Error Messages

    CHARGING MENDOR SMART BLOOD GLUCOSE METER ERROR MESSAGES When the meter starts charging, the battery icon and its status will be displayed If error occurs while using the meter, the error screen is displayed and the me- on the screen as shown on the previous page.
  • Page 21: Caring For Your System

    Solution Repeat the test with a new test strip. Error 5 Cause Strip insertion error. Please insert a Mendor test Solution strip properly. Error 6 Cause Meter failure. Contact the manufacturer of the Solution blood glucose meter.
  • Page 22: General Trouble Shooting

    GENERAL TROUBLE SHOOTING PERFORMANCE CHARACTERISTICS The performance of Mendor SMART Blood Glucose Monitoring System has been evaluated in laboratory and in clinical tests. Problem Troubleshooting Accuracy: Check whether the test strip is inserted with the The display is blank The accuracy of Mendor SMART Blood Glucose Meter System contact bars facing up.
  • Page 23: Warranty Information

    Manufacturer’s Warranty i-SENS, Inc. 43, Banpo-daero 28-gil, Seocho-gu, Mendor warrants that the meter shall be free of defects in material and work- manship in normal use for a period of two (2) years. The meter must have been Seoul 06646, Korea subjected to normal use.
  • Page 24 FCC Part 15.19 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Table of Contents