Warmington Studio Stove Installation Instructions Manual

Warmington Studio Stove Installation Instructions Manual

Clean air approved wood burner
Hide thumbs Also See for Studio Stove:

Advertisement

Quick Links

17 October 2014
Studio Stove
Studio Stove—Clean Air Approved Wood Burner

Installation Instructions

Visit www.warmington.co.nz for Spec's, DWG's and PDF uploads of Fires
Fire, Flue System and instructions to comply with ASNZS 2918:2001
Keep these Instructions for future reference......Ensure that you have the correct and current Installation details for the Warmington Fire
Installation
The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician .
See www.homeheat.co.nz/members for a Certified NZHHA SFAIT Installer in your area .
CLEARANCES TO COMBUSTIBLE SURFACES UNLESS STATED
IMPORTANT
Read all the Instructions carefully before commencing the Installation. Failure to follow these Instructions may result in a Fire Hazard and void the warranty
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
All Dimension are in mm.............Copyright ©
1

Advertisement

Table of Contents
loading

Summary of Contents for Warmington Studio Stove

  • Page 1: Installation Instructions

    Visit www.warmington.co.nz for Spec’s, DWG’s and PDF uploads of Fires Fire, Flue System and instructions to comply with ASNZS 2918:2001 Keep these Instructions for future reference……Ensure that you have the correct and current Installation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician .
  • Page 2 Performance may vary from tested values depending on actual operating conditions. Date of installation: _____/_____/20_____ Free down load of operating instructions from the website . www.warmington.co.nz Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 3: Floor Protector

    Minimum Flue Height Loading Badge Flue Height 3600 Packed By Measured From Top of Cabinet C + 3600 Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 4 * Construction of Flue Shield must be in accordance with ASNZS 2918 (minimum Flue Shield height is 1200mm) BAFFLE POSITION Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 5 Move the Back of the Baffle up to sit on the Pins at the Back of the Firebox Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 6 Wet back is to be fitted to an internal heat-sync (e.g. Hot water cylinder / Radiator / Under floor heating etc… Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 7: Flue Details

    It is the responsibility of the installer to ensure that the installation of the flue kit complies with AS/NZ 2918:2001, the appliance manufacture’s specifications for flues and that relevant Local Body requirements are adhered to. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 8 All external air vents & ceiling penetrations must be bird proofed with permanently fixed screens. All flashing to comply with E2. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 9: General Information & Operation

    1. Double Skin The Studio Stove convection stove – it has an inner and outer skin whereby room air flows between the surfaces, thus becoming hot and efficiently heating the room . Because the outer skin stays relatively cooler , this type of Stove is much safer than a Full Radiation Stove (i.e. Pot Belly) the top & side surfaces will get hot .
  • Page 10: Floor Protection

    10. Testing The Studio Stove has the Fire Box tested and approved to ASNZS 2918:2001 specifications for Solid Fuel burning heaters & also to AS/NZS 4012 giving compliance with MFE (Ministry for the Enviroment New Zealand) clean air requirements in New Zealand &...
  • Page 11 Ensure that both glass & door surfaces are clean and true . remove the glass and any shards. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 12: Important Note

    Fit the bottom glass retainer. DO NOT OVER TIGHTEN AS GLASS MAY CRACK/BREAK . Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 13 Tighten up the Cap Screws on the ensure that it is parallel Top & Bottom Door Front first . Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 14 Nip up screws while holding door in place, then tighten fully with a 5mm Allen Key. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 15 Paint (Stovebright) Handles 17. Installation The fire is to be Installed by a Approved Warmington Installer or an Approved NZHHA SFAIT Installation Technician . See www.homeheat.co.nz/members for a NZHHA SFAIT Installer in your area . GENERAL INFORMATION ON PAINT & FINISHING Information on the paint coating is on the web site: http://www.forrestpaint.com/stovebright/troubleshooting_guide1.html...
  • Page 16 NOTE: For Operation Instruction download from the website www.warmington.co.nz Industries 1994 LTD PO Box 58652, Botany 2163, Auckland www.warmington.co.nz Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...

This manual is also suitable for:

Studio oh-ah 14

Table of Contents