Summary of Contents for Real Fires 900

  • Page 1 Real Fires Through wall Installation Instructions realfi res.co.nz...
  • Page 2: Framing Details

    Minimal Model 900 Real Fires Through wall Model is designed for installation into Timber framed cavities. It is not suitable for existing masonry situations. Ventilation Ventilation to the room that houses the fi re must meet the requirements of NZS5261.
  • Page 3: Electrical Supply

    Height of re from oor It is important to confi rm the height the fi re is to be installed above the fl oor level. This is usually the hearth height. For example if the hearth is 100mm high then the fi re needs to be 100mm high ( note- some elevated installations specify the fi...
  • Page 4: Flue Requirements

    Recessed rebox installation Standard wall linings are not suitable for recessed installation Please contact Real Fires for advice prior to installation Flue requirements The minimum fl ue height is 2.4 metres. The Through wall fi re has two fl ue outlets. Two separate fl ues connect to the fl...
  • Page 5 The Firebox and the fl ue should be secured by fi xing with seismic strapping and/or brackets to framing. Flue bends are available from Real Fires if the fl ue needs to be o set. Appropriate weatherproof roof fl ashing/ chimney cap- ping must be used to comply with NZS 5261.
  • Page 6 Natural Gas burner Fill the burner tray with the vermiculite supplied ensuring the burner tube is completely covered. Place the large logs across each other in the centre of the burner and the twigs and coals around them to cover the burner with open spacings to allow the radiant heat escape.
  • Page 7 The through wall fi re can be installed through an outside wall with the glass on the outside. In these situations a second glass panel must be ordered and fi tted over the existing glass panel at the time of installation. Please note Real Fires do not supply any weatherproof fl ashings for the through wall fi re. Instruct User Once the installation is complete, instruct the user on the operation of the fi...
  • Page 8 realfi res.co.nz...
  • Page 9 realfi res.co.nz...
  • Page 10 realfi res.co.nz...
  • Page 11 Real Fires Log and Coal Layout This drawing is a typical example of the log and coal layout on a Real Fire 800. The layout is basically the same for Real Fires Log and Coal Layout all models with logs and coals decreased or increased in width to suit the size of fi re. (The pilot ignition assembly has been omitted from the drawing).