Programming/Audio Import/Export
Button
opens a window with the following functions.
Export Programming: click on this button to export the current settings from the Console to a USB key.
Import Programming: click on this button to import a communicator's settings from a USB key to the Console; the
settings may be those previously exported from a Console running on another PC, or from a communicator.
Export Audio: click on this button to export the voice messages from the Console to a USB key.
Import Audio: click on this button to import the voice messages from a USB key to the Console; the messages may
be those previously exported from a Console running on another PC, or from a communicator.

Restore Factory Settings

To restore the communicator's factory settings, proceed as follows.
1.
Shut off power to the communicator.
2.
Short pins 1 and 4 of the PC LINK 15 connector and restore power.
3.
All LEDs will turn on, and after a few seconds the green ones will turn off to indicate that the factory restore is in progress.
4.
You can now remove the short connection between pins 1 and 4 of connector 15.
5.
Once the procedure terminates, the LEDs
other LEDs remain off.
Recorded voice messages are NOT deleted by the factory restore procedure. Voice messages can be deleted in the Console's
Voice Messages page.
The factory restore procedure may NOT be executed if the communicator is ONLY powered by its backup battery; you must
reconnect its primary power supply.
38
will flash to indicate that the PINs have been restored to their values; the
Universal Cellular Communicator