Moxa Technologies AWK-1121 User Manual
Moxa Technologies AWK-1121 User Manual

Moxa Technologies AWK-1121 User Manual

Wireless client adaptors
Hide thumbs Also See for AWK-1121:
Table of Contents

Advertisement

AirWorks AWK-1121/1127 User's Manual
Second Edition, April 2014
www.moxa.com/product
© 2014 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
www.ipc2u.ru
www.moxa.pro

Advertisement

Table of Contents
loading

Summary of Contents for Moxa Technologies AWK-1121

  • Page 1 AirWorks AWK-1121/1127 User’s Manual Second Edition, April 2014 www.moxa.com/product © 2014 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. www.ipc2u.ru www.moxa.pro...
  • Page 2: Copyright Notice

    AirWorks AWK-1121/1127 User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement. Copyright Notice ©2014 Moxa Inc. All rights reserved. Trademarks The MOXA logo is a registered trademark of Moxa Inc.
  • Page 3: Table Of Contents

    Table of Contents Introduction ............................1-1 Overview ............................1-2 Package Checklist ..........................1-2 Product Features ..........................1-2 Product Specifications ......................... 1-3 Functional Design ..........................1-5 LED Indicators ..........................1-5 Beeper ............................1-5 Reset Button ..........................1-6 Getting Started..........................2-1 First-time Installation and Configuration ....................2-2 Function Map .............................
  • Page 4 Installing the UNIX Driver......................4-17 Configuring the UNIX Driver ....................... 4-18 Other Console Considerations ......................5-1 RS-232 Console Configuration (115200, None, 8, 1, VT100) ..............5-2 Configuration by Telnet and SSH Consoles ..................... 5-3 Configuration by Web Browser with HTTPS/SSL ..................5-4 Disabling Telnet and Browser Access .....................
  • Page 5: Introduction

    The AirWorks AWK-1121/1127 enables wireless users to access network resources wirelessly. The AWK-1121/1127 is rated to operate at temperatures ranging from 0 to 60°C for standard models and -40 to 75°C for wide temperature models, and is rugged enough for any harsh industrial environment.
  • Page 6: Overview

    Introduction Overview The AWK-1121/1127 Client is ideal for applications that are hard to wire, too expensive to wire, or use mobile equipment that connects to a TCP/IP network. The AWK-1121/1127 can operate at temperatures ranging from 0 to 60°C for standard models and -40 to 75°C for wide temperature models, and is rugged enough for any harsh industrial environment.
  • Page 7: Product Specifications

    AWK-1121/1127 Introduction Product Specifications WLAN Interface Standards: IEEE 802.11a/b/g for Wireless LAN IEEE 802.11i for Wireless Security IEEE 802.3u for 10/100BaseT(X) IEEE 802.3af for Power-over-Ethernet (PoE model) Spread Spectrum and Modulation (typical): • DSSS with DBPSK, DQPSK, CCK • OFDM with BPSK, QPSK, 16QAM, 64QAM •...
  • Page 8 Details: See www.moxa.com/warranty ATTENTION • The AWK-1121/1127 is NOT a portable mobile device and should be located at least 20 cm away from the human body. • The AWK-1121/1127 is NOT designed for the general public. A well-trained technician should be enlisted to ensure safe deployment of AWK-1121/1127 units, and to establish a wireless network.
  • Page 9: Functional Design

    Functional Design LED Indicators The LEDs on the front panel of the AWK-1121/1127 provide a quick and easy means of determining the current operational status and wireless settings. The FAULT LED indicates system failures and user-configured events. If the AWK-1121/1127 cannot retrieve the IP address from a DHCP server or if there is an IP conflict, the FAULT LED will blink at one second intervals.
  • Page 10: Reset Button

    Introduction Reset Button The RESET button is located on the back panel of the AWK-1121/1127. You can reboot the AWK-1121/1127 or reset it to factory default settings by pressing the RESET button with a pointed object such as an unfolded paper clip.
  • Page 11: Getting Started

    Getting Started This chapter explains how to install Moxa’s AirWorks AWK-1121/1127 for the first time, and quickly set up your wireless network and test whether the connection is running well. The function guide provides a convenient means of determining which functions you need to use.
  • Page 12: First-Time Installation And Configuration

    First-time Installation and Configuration Before installing the AWK-1121/1127, make sure that all items in the Package Checklist are in the box. You will need access to a notebook computer or PC equipped with an Ethernet port. The AWK-1121/1127 has a default IP address that must be used when connecting to the device for the first time.
  • Page 13 Communication Testing After installing the AWK-1121/1127 a simple test may be run against an AP to make sure the AWK-1121/1127 has properly established a wireless connection and is functioning normally. In the example below, an AWK-3121 is used as the primary access point.
  • Page 14: Function Map

    AWK-1121/1127 Getting Started Function Map Quick overview of the AWK-1121/1127’s information Basic settings for administering the AWK-1121/1127 Essential settings related to establishing a wireless network Advanced features to support additional network management and secure wired and wireless communication Note: These advanced functions are all optional.
  • Page 15: Web Console Configuration

    Web Console Configuration In this chapter, we explain all aspects of web-based console configuration. Moxa’s easy-to-use management functions help you set up your AWK-1121/1127 and make it easy to establish and maintain your wireless network. The following topics are covered in this chapter: ...
  • Page 16: Web Browser Configuration

    To use the AWK-1121/1127’s management and monitoring functions from a PC host connected to the same LAN as the AWK-1121/1127, you must make sure that the PC host and the AWK-1121/1127 are on the same logical subnet. Similarly, if the AWK-1121/1127 is configured for other VLAN settings, you must make sure your PC host is on the management VLAN.
  • Page 17: Overview

    NOTE For security reasons, you will need to log back into the AWK-1121/1127 after a 5-minute time-out. Overview The Overview page summarizes the AWK-1121/1127’s current status. The information is categorized into several groups: System Info, Device Info, and 802.11 Info.
  • Page 18: Basic Settings

    System Info labels (especially Device name) are displayed and included on the Overview page, in SNMP information, and in alarm emails. Giving descriptive, unique labels to items under System Info makes it easier to identify the different AWK-1121/1127 units connected to your network. Device name...
  • Page 19: Time Settings

    Date and Time information. Functions such as Auto warning can add real-time information to the message. The Current local time shows the AWK-1121/1127’s system time when you open this web page. You can click on the Set Time button to activate the updated date and time parameters. An “(Updated)” string will appear to indicate that the change is complete.
  • Page 20: Wireless Settings

    Familiarize yourself with the following terms before starting the configuration process: The AWK-1121/1127 as a client can be used as an Ethernet-to-wireless (or LAN-to-WLAN) network adapter. For example, a notebook computer equipped with an Ethernet adaptor but no wireless card can be connected to this device with an Ethernet cable to provide wireless connectivity to another AP.
  • Page 21: Operation Mode

    AWK-1121/1127 to either the 2.4GHz or 5GHz frequency band. An SSID is a unique identifier that wireless networking devices use to establish and maintain wireless connectivity. Set the SSID parameter to match that of the APs you wish to connect to, so that the AWK-1121/1127 will associate with network defined by the SSID.
  • Page 22 The AWK-1121/1127-JP (for Japanese frequency bands) connects only APs with broadcast (i.e: not hidden) SSIDs, in all IEEE802.11a channels and IEEE802.11g channels 1 to 11. The AWK-1121/1127-EU (for European frequency bands) only connects APs with hidden SSIDs in all IEEE802.11b/g channels.
  • Page 23 When WEP is enabled as a security mode, the length of a key (so-called WEP seed) can be specified as 64/128 bits, which is actually a 40/104-bit secret key with a 24-bit initialization vector. The AWK-1121/1127 provides 4 entities of WEP key settings that can be selected to use with Key index. The selected key setting specifies the key to be used as a send-key for encrypting traffic from the AP side to the wireless client side.
  • Page 24 Even though AES encryption is only included in the WPA2 standard, it is widely available in the WPA security mode of some wireless APs and clients as well. The AWK-1121/1127 also supports AES algorithms in WPA and WPA2 for better compatibility.
  • Page 25 Master key to generate keys for encryption and decryption None WPA/WPA2-Enterprise When used as a client, the AWK-1121/1127 can support three EAP methods (or EAP protocols): EAP-TLS, EAP-TTLS, and EAP-PEAP, corresponding to WPA/WPA2-Enterprise settings on the AP side. EAP Protocol...
  • Page 26 Certificate reduction makes TTLS and PEAP much more popular than EAP-TLS. The AWK-1121/1127 provides some non-cryptographic EAP methods, including PAP, CHAP, MS-CHAP, and MS-CHAP-V2. These EAP methods are not recommended for direct use on wireless networks. However, they may be useful as inner authentication methods with TTLS and PEAP.
  • Page 27 There are a few differences in the TTLS and PEAP inner authentication procedures. TTLS uses the encrypted channel to exchange attribute-value pairs (AVPs), while PEAP uses the encrypted channel to start a second EAP exchange inside of the tunnel. The AWK-1121/1127 provides MS-CHAP-V2 merely as an EAP method for inner authentication.
  • Page 28 Additional wireless-related parameters are presented in this section to help you set up your wireless network in detail. Transmission Rate Setting Description Factory Default Auto The AWK-1121/1127 senses and adjusts the data rate Auto automatically Available rates Users can manually select a target transmission data rate Transmission Power Setting...
  • Page 29 Moxa’s Turbo Roaming can enable rapid handover when the Disable AWK-1121/1127, as a client, roams among a group of APs. When Turbo Roaming is enabled, the RF type, AP alive check, and Scan channels will be shown as follows. RF type shows the current RF type that this client is using.
  • Page 30: Advanced Settings

    Current status. If it fails, you may need to return to step 1 to set the password correctly and then import the certificate file again. NOTE The WLAN certificate will remain after the AWK-1121/1127 reboots. Even though it is expired, it can still be seen on the Current status. Advanced Settings Several advanced functions are available to increase the functionality of your AWK-1121/1127 and wireless network system.
  • Page 31: Packet Filters

    = all packets are denied IP Protocol Filter The AWK-1121/1127’s IP protocol filter is a policy-based filter that can allow or filter out IP-based packets with specified IP protocol and source/destination IP addresses. The AWK-1121/1127 provides 8 entities for setting IP protocol and source/destination IP addresses in your filtering policy.
  • Page 32 “no TCP/UDP Port Filter The AWK-1121/1127’s TCP/UDP port filter is a policy-based filter that can allow or filter out TCP/UDP-based packets with a specified source or destination port. The AWK-1121/1127 provides 8 entities for setting the range of source/destination ports of a specific protocol.
  • Page 33: Snmp Agent

    MD5 or SHA, is the most secure protocol. You can also enable data encryption to enhance data security. The AWK-1121/1127’s MIB can be found in the software CD and supports reading the attributes via SNMP. (Only get method is supported.) SNMP security modes and security levels supported by the AWK-1121/1127 are shown in the following table.
  • Page 34 AWK-1121/1127 Web Console Configuration The following parameters can be configured on the SNMP Agent page. A more detailed explanation of each parameter is given below the following figure. Enable Setting Description Factory Default Enable Enables SNMP Agent Disable Disable Disables SNMP Agent...
  • Page 35: Link Fault Pass-Through

    Ethernet link is recovered, AWK-1121/1127 will try to connect to AP. If wireless is disconnected, AWK-1121/1127 restarts auto-negotiation on Ethernet port but always stays in the link failure state. Once the wireless connection is recovered, AWK-1121/1127 will try to recover the Ethernet link.
  • Page 36: Operation Modes

    AWK-1121/1127 Web Console Configuration Operation Modes The Operation Modes page for the serial port is where you can configure the serial port operation mode and related settings. Application This field specifies what kind application you will be using for this serial port. Depending on the application, different operation modes and related settings will be displayed.
  • Page 37 AWK-1121/1127 Web Console Configuration RealCOM Mode RealCOM mode is designed to work with AWK drivers that are installed on a network host. COM drivers are provided for Windows systems, and TTY drivers are provided for Linux and UNIX systems. The driver establishes a transparent connection to the attached serial device by mapping a local serial port to the AWK-1127 serial port.
  • Page 38 AWK-1121/1127 Web Console Configuration When Mode is set to RealCOM on a serial port’s Operation Modes page, you will be able to configure additional settings such as TCP alive check time, Max connection, and Ignore jammed IP. TCP Alive Check Time...
  • Page 39 AWK-1121/1127 Web Console Configuration Allow Driver Control This field specifies how the port will proceed if driver control commands are received from multiple hosts that are connected to the port. Setting Description Factory Default Disable Driver control commands will be ignored.
  • Page 40 AWK-1121/1127 Web Console Configuration Delimiter Process This field specifies how data is packed when delimiter characters are received. This field has no effect if Delimiter 1 is not enabled. Setting Description Factory Default Do Nothing Data accumulated in the serial port’s buffer will be packed, Do Nothing including delimiters.
  • Page 41 AWK-1121/1127 Web Console Configuration RFC2217 Mode RFC2217 mode is similar to RealCOM mode, since it relies on a driver to transparently map a virtual COM port on a host computer to a serial port on the AWK-1127. The RFC2217 standard defines general COM port control options based on the Telnet protocol and supports one connection at a time.
  • Page 42 AWK-1121/1127 Web Console Configuration Packet Length Setting Description Factory Default 0 to 1024 This field specifies the maximum amount of data that is allowed to accumulate in the serial port buffer before sending. 0: Packet length is disregarded and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full.
  • Page 43 AWK-1121/1127 Web Console Configuration Force Transmit Setting Description Factory Default 0 to 65535 This field controls data packing by the amount of time that 0 ms elapses between bits of data. When using this field, make sure that Inactivity time is disabled or set to a larger value.
  • Page 44 AWK-1121/1127 Web Console Configuration TCP Server Mode In TCP Server mode, the AWK-1127 serial port is assigned an IP:port address that is unique on your TCP/IP network. It waits for the host computer to establish a connection to the attached serial device. This operation mode also...
  • Page 45 AWK-1121/1127 Web Console Configuration When Mode is set to TCP Server on a serial port’s Operation Modes page, you will be able to configure additional settings such as TCP alive check time, Inactivity time, and Max connection. TCP Alive Check Time...
  • Page 46 AWK-1121/1127 Web Console Configuration Allow Driver Control This field specifies how the port will proceed if driver control commands are received from multiple hosts that are connected to the port. Setting Description Factory Default Disable Driver control commands will be ignored.
  • Page 47 AWK-1121/1127 Web Console Configuration ATTENTION When Delimiter 1 is enabled, Packet length must be set to 0. Delimiter Process This field specifies how data is packed when delimiter characters are received. This field has no effect if Delimiter 1 is not enabled.
  • Page 48 AWK-1121/1127 Web Console Configuration TCP Client Mode In TCP Client mode, the AWK-1127 actively establishes a TCP connection to a specific network host when data is received from the attached serial device. After the data has been transferred, the AWK-1127 can automatically disconnect from the host computer through the Inactivity time settings.
  • Page 49 AWK-1121/1127 Web Console Configuration When Mode is set to TCP Client on a serial port’s Operation Modes page, you will be able to configure additional settings such as TCP alive check time, Inactivity time, and Ignore jammed IP. TCP Alive Check Time...
  • Page 50 AWK-1121/1127 Web Console Configuration Designated Local Port 1 to 4 Setting Description Factory Default 1 to 65535 This field specifies the TCP port number that will be used for data transmission with the serial port. Connection Control This field specifies how connections to the device are established and closed.
  • Page 51 AWK-1121/1127 Web Console Configuration ATTENTION When Delimiter 1 is enabled, Packet length must be set to 0. Delimiter Process This field specifies how data is packed when delimiter characters are received. This field has no effect if Delimiter 1 is not enabled.
  • Page 52 AWK-1121/1127 Web Console Configuration UDP Mode UDP is similar to TCP but is faster and more efficient. Data can be broadcast to or received from multiple network hosts. However, UDP does not support verification of data and would not be suitable for applications where data integrity is critical.
  • Page 53 AWK-1121/1127 Web Console Configuration Local Listen Port Setting Description Factory Default 0 to 9999 This field specifies the UDP port that the AWK-1127 listens to 4001 and that other devices must use to contact the attached serial device. Packet Length...
  • Page 54: Communication Parameters

    AWK-1121/1127 Web Console Configuration Force Transmit Setting Description Factory Default 0 to 65535 This field controls data packing by the amount of time that 0 ms elapses between bits of data. When using this field, make sure that Inactivity time is disabled or set to a larger value.
  • Page 55 AWK-1121/1127 Web Console Configuration ATTENTION Serial communication settings should match the attached serial device. Check the communication settings in the user’s manual for your serial device. Baud Rate Setting Description Factory Default 50, 75, 110, 134, 150, This field specifies the baudrate for the serial port.
  • Page 56: Data Buffering/Log

    In addition to logging these events, the AWK-1121/1127 supports different approaches to warn engineers automatically, such as SNMP trap or e-mail.
  • Page 57: System Log

    Config-related events Event is triggered when… Configuration Changed A configuration item has been changed. Configuration file import via Web Console The configuration file is imported to the AWK-1121/1127. Console authentication failure An incorrect password is entered. Firmware upgraded The AWK-1121/1127’s firmware is updated.
  • Page 58: Syslog

    AWK-1121/1127 Web Console Configuration Syslog This function provides the event logs for the Syslog server. The function supports up to three configurable Syslog servers and Syslog server UDP port numbers. When an event occurs, the event will be sent as a Syslog UDP packet to the specified Syslog servers.
  • Page 59: E-Mail

    “System Log Event Types” table on page 3-40. E-mail Server Settings You can set up to 4 e-mail addresses to receive alarm emails from the AWK-1121/1127. The following parameters can be configured on the E-mail Server Settings page. In addition, a Send Test Mail button can be used to test whether the Mail server and e-mail addresses work well.
  • Page 60: Trap

    AWK-1121/1127 Web Console Configuration From e-mail address Setting Description Factory Default Max. 63 characters Enter the administrator’s e-mail address which will be shown in None the “From” field of a warning e-mail. To E-mail address 1/ 2/ 3/ 4 Setting...
  • Page 61: Status

    Status page. The status will refresh every 5 seconds if the Auto refresh box is checked. It is helpful to use the continuously updated information on this page, such as Signal strength, to monitor the signal strength of the AWK-1121/1127. 3-47 www.ipc2u.ru...
  • Page 62: System Log

    AWK-1121/1127 Web Console Configuration System Log Triggered events are recorded in System Log. You can export the log contents to an available viewer by clicking Export Log. You can use the Clear Log button to clear the log contents and the Refresh button to refresh the log.
  • Page 63: Maintenance

    AWK-1121/1127 Web Console Configuration Maintenance Maintenance functions provide the administrator with tools to manage the AWK-1121/1127 and wired/wireless networks. Console Settings You can enable or disable access permission for the following consoles: HTTP, HTTPS, Telnet and SSH connections. For more security, we recommend you only allow access to the two secured consoles, HTTPS and SSH.
  • Page 64: Firmware Upgrade

    Moxa’s download center. Before running a firmware upgrade, make sure the AWK-1121/1127 is off-line. Click the Browse button to specify the firmware image file and click Firmware Upgrade and Restart to start the firmware upgrade. After the progress bar reaches 100%, the AWK-1121/1127 will reboot itself.
  • Page 65: Loading Factory Defaults

    Loading Factory Defaults Use this function to reset the AWK-1121/1127 and roll all settings back to the factory default values. You can also reset the hardware by pressing the reset button on the rear panel of the AWK-1121/1127.
  • Page 66: Misc. Settings

    The following figure shows how the AWK-1121/1127 stores the setting changes into volatile and non-volatile memory. All data stored in volatile memory will disappear when the AWK-1121/1127 is shutdown or rebooted unless they are saved in non-volatile memory. Because the AWK-1121/1127 starts up and initializes with the settings stored in flash memory, all new changes must be saved to flash memory before restarting the AWK-1121/1127.
  • Page 67: Restart

    If you made changes recently but did not save, you will be given two options. Clicking the Restart button here will reboot the AWK-1121/1127 directly, and all setting changes will be ignored. Clicking the Save and Restart button will apply all setting changes and then reboot the AWK-1121/1127.
  • Page 68: Software Installation And Configuration

    Software Installation and Configuration The following topics are covered in this chapter:  Overview  AWK Search Utility  Installing AWK Search Utility  Configuring the AWK Search Utility  OnCell Windows Driver Manager  Installing OnCell Windows Driver Manager ...
  • Page 69: Overview

    Software Installation and Configuration Overview The Documentation & Software CD included with your AWK-1121/1127 is designed to make the installation and configuration procedure easy and straightforward. This auto-run CD includes AWK Search Utility (to broadcast search for all AWK’s accessible over the network), the AWK-1121/1127 User’s Manual, and Quick Installation Guide.
  • Page 70 AWK-1121/1127 Software Installation and Configuration 1. Click Next to create the program’s shortcut files to the default directory, or click Browse to select an alternate location. 2. Click Next to select additional tasks. 3. The installer then displays a summary of the installation options.
  • Page 71: Configuring The Awk Search Utility

    Configuring the AWK Search Utility The Broadcast Search function is used to locate all AWK-1121/1127 APs that are connected to the same LAN as your computer. After locating an AWK-1121/1127, you will be able to change its IP address. Since the Broadcast Search function searches by TCP packet and not IP address, it doesn’t matter if the AWK-1121/1127...
  • Page 72 AWK-1121/1127 Software Installation and Configuration 3. The “Searching” window indicates the progress of the search. When the search is complete, all AWKs that were located will be displayed in the AWK Search Utility window. 4. Click Locate to cause the selected device to beep.
  • Page 73 AWK-1121/1127 Software Installation and Configuration ATTENTION For security purposes, we suggest you can change the AWK search utility login password instead of using the default. To modify the configuration of the highlighted AWK, click on the Web icon to open the web console. This will take you to the web console, where you can make all configuration changes.
  • Page 74 AWK-1121/1127 Software Installation and Configuration The three advanced options—Search, Connection, and Miscellaneous—are explained below: Search • Retry count (default=5): Indicates how many times the search will be retried automatically. Retry interval (ms): The time lapsed between retries. • Connection •...
  • Page 75: Oncell Windows Driver Manager

    AWK-1121/1127 Software Installation and Configuration OnCell Windows Driver Manager The AWK-1127 uses the same RealCom serial driver as Moxa’s OnCell cellular gateways. The below section describes how to use the OnCell Windows Driver Manager to create a virtual COM port for the AWK-1127 in RealCom mode.
  • Page 76 AWK-1121/1127 Software Installation and Configuration 4. Click Next to proceed with the installation. The installer then displays a summary of the installation options. 5. Click Install to begin the installation. The setup window will report the progress of the installation. To change the installation settings, click Back and navigate to the previous screen.
  • Page 77: Using Oncell Windows Driver Manager

    AWK-1121/1127 Software Installation and Configuration Using OnCell Windows Driver Manager After you install OnCell Windows Driver Manager, you can set up the AWK-1127 ’s serial ports as remote COM ports for your PC host. Make sure that the serial port(s) on your AWK-1127 are set to RealCOM mode when mapping COM ports with OnCell Windows Driver Manager.
  • Page 78 AWK-1121/1127 Software Installation and Configuration 4. COM ports and their mappings will appear in blue until they are activated. Activating the COM ports saves the information in the host system registry and makes the COM port available for use. The host computer will not have the ability to use the COM port until the COM ports are activated.
  • Page 79 AWK-1121/1127 Software Installation and Configuration 6. Ports that have been activated will appear in black. 7. Click on the created COM port to select it. Then right click to select Basic Setting tab. On the Basic Setting tab, use the COM Number drop-down list to select a COM number to be assigned to the AWK-1127’s serial port that is being configured.
  • Page 80 AWK-1121/1127 Software Installation and Configuration Tx Mode Hi-Performance is the default for Tx mode. After the driver sends data to the AWK-1127 , the driver immediately issues a “Tx Empty” response to the program. Under Classical mode, the driver will not send the “Tx Empty”...
  • Page 81 AWK-1121/1127 Software Installation and Configuration 9. The Serial Parameters tab in the following figure show the default settings when the AWK-1127 is powered on. However, the program can redefine the serial parameters to different values after the program opens the port with Win32 API.
  • Page 82: Moxa Oncell Linux Real Tty Driver

    AWK-1121/1127 Software Installation and Configuration 11. To save the configuration to a text file, select Export from the COM Mapping menu. You will then be able to import this configuration file to another host and use the same COM Mapping settings in the other host.
  • Page 83: Mapping Tty Ports

    AWK-1121/1127 Software Installation and Configuration 7. After installing the driver, you will be able to see several files in the /usr/lib/oncell_realtty/driver folder: > mxaddsvr (Add Server, mapping tty port) > mxdelsvr (Delete Server, un-mapping tty port) > mxloadsvr (Reload Server) >...
  • Page 84: Removing Mapped Tty Ports

    AWK-1121/1127 Software Installation and Configuration Removing Mapped TTY Ports After logging in as root, enter the directory /usr/lib/oncell_realtty/driver and then execute mxdelsvr to delete a server. The syntax of mxdelsvr is: mxdelsvr [IP Address] Example: # cd /usr/lib/oncell_realtty/driver # ./mxdelsvr 192.168.3.4 The following actions are performed when executing mxdelsvr: 1.
  • Page 85: Configuring The Unix Driver

    AWK-1121/1127 Software Installation and Configuration 4. Compile and Link For SCO UNIX: # make sco For UnixWare 7: # make svr5 For UnixWare 2.1.x, SVR4.2: # make svr42 Configuring the UNIX Driver Modify the configuration The configuration used by the oncellttyd program is defined in the text file oncellttyd.cf, which is in the same directory that contains the program oncellttyd.
  • Page 86: Other Console Considerations

    AWK-1121/1127 to a PC’s COM port, can be used if you do not know the AWK-1121/1127’s IP address. The other consoles can be used to access the AWK-1121/1127 over an Ethernet LAN, or over the Internet.
  • Page 87: Rs-232 Console Configuration (115200, None, 8, 1, Vt100)

    The serial console connection method, which requires using a short serial cable to connect the AWK-1121/1127 to a PC’s COM port, can be used if you do not know the AWK-1121/1127’s IP address. It is also convenient to use serial console configurations when you cannot access the AWK-1121/1127 over Ethernet LAN, such as in the case of LAN cable disconnections or broadcast storming over the LAN.
  • Page 88: Configuration By Telnet And Ssh Consoles

    Configuration by Telnet and SSH Consoles You may use Telnet or SSH client to access the AWK-1121/1127 and manage the console over a network. To access the AWK-1121/1127’s functions over the network from a PC host that is connected to the same LAN as the AWK-1121/1127, you need to make sure that the PC host and the AWK-1121/1127 are on the same logical subnet.
  • Page 89: Configuration By Web Browser With Https/Ssl

    Follow the steps below to access the console utility via Telnet or SSH client. 1. From Windows Desktop, run Start  Run, and then use Telnet to access the AWK-1121/1127’s IP address from the Windows Run window (you may also issue the telnet command from the MS-DOS prompt).
  • Page 90: Disabling Telnet And Browser Access

    HTTPS/SSL. (You can see the protocol in URL is https.) Then you can use the menu tree on the left side of the window to open the function pages to access each of AWK-1121/1127’s functions. Disabling Telnet and Browser Access If you are connecting the AWK-1121/1127 to a public network but do not intend to use its management functions over the network, then we suggest disabling both Telnet Console and Web Configuration.
  • Page 91: References

    References This chapter provides more detailed information about wireless-related technologies. The information in this chapter can help you administer your AWK-1121/1127s and plan your industrial wireless network better. The following topics are covered in this appendix:  Fragment  RTS threshold www.ipc2u.ru...
  • Page 92: Fragment

    AWK-1121/1127 References Fragment A lower setting means smaller packets, which will create more packets for each transmission. If you have decreased this value and experience high packet error rates, you can increase it again, but it will likely decrease overall network performance. Only minor modifications of this value are recommended.
  • Page 93: Supporting Information

    Supporting Information This chapter presents additional information about this manual and product. You can also learn how to contact Moxa for technical support. The following topics are covered in this appendix:  About This User’s Manual  DoC (Declaration of Conformity) ...
  • Page 94: About This User's Manual

    QIG (Quick Installation Guide), UM (User’s Manual) and related information. NOTE You can find out the hardware revision number of AWK-1121/1127 on the side label. The firmware version number can be seen on the Overview page, as follows: www.ipc2u.ru...
  • Page 95: Doc (Declaration Of Conformity

    The firmware setting is not accessible by the end user. R&TTE Compliance Statement Moxa declares that the apparatus AWK-1121/1127 complies with the essential requirements and other relevant provisions of Directive 1999/5/EC. This equipment complies with all the requirements of DIRECTIVE 1999/5/CE OF THE EUROPEAN PARLIAMENT AND THE COUNCIL OF 9 March 1999 on radio equipment and telecommunication terminal equipment and the mutual recognition of their conformity (R&TTE).
  • Page 96: Firmware Recovery

    Press Ctrl - C and the following message will appear. Enter 2 to change the network setting. Specify where the AWK-1121/1127’s firmware file on the TFTP server and press y to write the settings into flash memory.
  • Page 97 AWK-1121/1127 Supporting Information Select 0 in the sub-menu to load the firmware image via LAN, and then enter the file name of the firmware to start the firmware recovery. www.ipc2u.ru www.moxa.pro...

This manual is also suitable for: