Keypad Configure Parameter - Gaoke S1801 Manual

Fixed wireless terminal (analogue fax & gprs)
Table of Contents

Advertisement

4 Keypad configure parameter

notice :Keypad configure parameter set need off-hook, then on-hook and exit, parameter will auto
save. Indicating tone will inform configure success or failure, if success then release dialing tone, otherwise
release busy tone.
*-- begin as *, set; #-- begin as #, cancel, Followed two numbers indicate function code, function code and
content or contents are separated by *
X:digital key, 0~9.
Functions
Adjust incoming call volume
Adjust outgoing call volume
Functions
Input
parameter
password
Functions
Polarity reverse
PIN1
Modify PIN1
Set default parameter
Modify password
S1801 Fixed Wireless Terminal User's Manual
Table 4-1
Adjust voice volume
Parameter
command
##*X#
X:1-5
###X#
X:1-5
Table 4-2
Parameter command
set
##XXXX#
Table 4-3 Modify parameter after enter keypad set
Parameter command
Set
Cancel
*20#
#20#
*71*PIN1#
#71*PIN1#
*72*
old
PIN1*
PIN1*New PIN1#
*81#
**XXXX*XXXX#
(** New password * new
password #)
Specification
X indicates incoming call volume, from 1 to 5, 1
is lowest, 5 is highest.
Password is unnecessary for setting, you will
hear dialing tone if success.
X indicates incoming call volume, from 1 to 5, 1
is lowest, 5 is highest.
Password is unnecessary for setting, you will
hear dialing tone if success.
Keypad set
Specification
Success verify 4-digit password to enter
management(parameter set).
Specification
Send polarity reverse signal for charge
Set-send
Cancel- no send(default)
PIN1 Max 8-digit, no less than 4-digit.
New
Before modify PIN, PIN under active status
Set default parameter
Password is 4-digit.
Defaulted password is"1234" before factory.
Password cannot delete, only can replace old
password with new password.
Above
only
can
management(parameter set).
7
operate
after
enter

Advertisement

Table of Contents
loading

Table of Contents