Download Print this page
Ubiquiti mFi-CS Quick Start Manual
Ubiquiti mFi-CS Quick Start Manual

Ubiquiti mFi-CS Quick Start Manual

Current sensor

Advertisement

Quick Links

Current Sensor
Model: mFi-CS
Introduction
Thank you for purchasing the
Ubiquiti mFi
 Current Sensor. The
mFi Current Sensor is designed
for use with the mFi mPort. Once
they are connected, you can use
the mFi Controller software to
monitor your machines using
your Web browser.

Advertisement

loading

Summary of Contents for Ubiquiti mFi-CS

  • Page 1 Current Sensor Model: mFi-CS Introduction Thank you for purchasing the Ubiquiti mFi  Current Sensor. The ™ mFi Current Sensor is designed for use with the mFi mPort. Once they are connected, you can use the mFi Controller software to monitor your machines using...
  • Page 2: Installation Requirements

    Installation Requirements • mFi mPort • CAT5/6 Cable Applications You can install the mFi Current Sensor for various uses. For example, the following diagram depicts an mFi Current Sensor installed in an electrical panel. You can use its measurements to: • Monitor the current flow of this circuit •...
  • Page 3 To Machine Hot or Neutral Wire Circuit Breaker and Power Source mFi mPort...
  • Page 4: Ac Current Measurement

    AC Current Measurement The mFi Current Sensor measures the AC current flowing in the circuit, not the power. Note: Power is voltage multiplied by current. The mFi Current Sensor measures only the current (up to 100A maximum), and not the voltage. The result indicates non-TrueRMS (Root Mean Square) current in amps, which may require additional analysis for non-linear...
  • Page 5: Ubiquiti Networks Support

    Phone: 408-942-1153 (9 a.m. - 5 p.m. PST) Online Resources wiki.ubnt.com Wiki Page: Support Forum: forum.ubnt.com Downloads: downloads.ubnt.com w w w . u b n t . c o m © 2012 Ubiquiti Networks, Inc. All rights reserved. JL042512...
  • Page 6: Installation

    Current Sensor Model: mFi-CS Installation 1. Lift the latch to open the mFi Current Sensor.
  • Page 7 2. Insert one wire (either hot or neutral) of the AC wire pair into the opening of the mFi Current Sensor.
  • Page 8 3. Close the opening of the mFi Current Sensor until the latch snaps into place.
  • Page 9 4. Connect a CAT5/6 cable to the mFi RJ45 port of the mFi Current Sensor.
  • Page 10 5. Connect the other end of the CAT5/6 cable from the mFi Current Sensor to an mFi RJ45 port on the mFi mPort. Refer to the User Guide on the CD-ROM that was included with your mFi mPort for instructions on configuring the mFi Current Sensor in the mFi Controller software.