Basic safety precautions should always be followed, including the following: Failure to
follow instructions can cause severe injury and/or death.
This is the safety-alert symbol. When you see this symbol on your equipment or in
this manual, look for one of the following signal words and be alert to the potential for
personal injury.
WARNING warns about hazards that could cause serious personal injury, death or
major property damage and if ignored presents a potential hazard.
CAUTION warns about hazards that will or can cause minor or moderate personal
injury and/or property damage and if ignored presents a potential hazard. It can also
make consumers aware of actions that are unpredictable and unsafe.
The NOTICE label indicates special instructions that are important but not related to
hazards.
Hayward Pool Products Canada
2880 Plymouth Drive, Oakville ON L6H 5R4
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Transformer
and CrystaLogic
®
Owner's Manual
Contents
Introduction....................3
Installation.....................4
Warranty........................9
LTBCY11300
Haywardpool.ca
Pool/Spa Lights
TM
092498HC RevA

Advertisement

loading
Need help?

Need help?

Do you have a question about the LTBCY11300 and is the answer not in the manual?

Questions and answers

Luigi Marra
July 19, 2025

What is the proper way to choose the desired colour. Instructions say to press button number of times to choose the colour or sets of colours. Do I do this every time I want to change desiredcolor.

Summary of Contents for Hayward LTBCY11300

  • Page 1 The NOTICE label indicates special instructions that are important but not related to hazards. Hayward Pool Products Canada 2880 Plymouth Drive, Oakville ON L6H 5R4 Haywardpool.ca USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 2 WARNING – Networked ColorLogic Lights and related electrical con- nections are receiving electrical power at all times, even when the lights are OFF! Turn off power at the main breaker before servicing ColorLogic lights. SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 3 The Hayward 300 Watt Pool Transformer LTBCY11300 is a low voltage transformer for use with ® pool and spa lights and submersible fixtures. It can be used to power up to four Hayward Universal ColorLogic and CrystaLogic LED lights and offers a dedicated mounting location for the Coupler ®...
  • Page 4 The transformer should be mounted at least 1 foot above the deck level with the field wiring compartment down. • Locate the LTBCY11300 at least 10 feet (3m) away from the inside wall of the pool. • Make sure that all unused taps (leads) are separately insulated.
  • Page 5 Connecting directly to Pool/Spa Light When the low voltage pool light will be directly connected to the LTBCY11300, use the included non-metallic conduit adaptor and duct seal. Refer to the diagram below. Any connections to the bus bar should be tightened to 10 in/lbs.
  • Page 6 Pool or Spa Lights For field wiring information, please refer to the instructions attached to the inside front cover of the LTBCY11300 as well as the diagram below. Hayward LTBCY11300 300 watt transformer powering low voltage Pool or Spa Lights...
  • Page 7 Before starting system pump, fully open filter manual air relief valve. Do not close filter manual air relief valve until a steady stream of water (not air or air and water) is discharged. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 8 A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 9 To obtain warranty service, please contact the place of purchase or the nearest Hayward Authorized Service Center. For as- sistance on your nearest Hayward Authorized Service Center please visit us at www.hayward.com. Hayward shall not be responsible for cartage, removal, repair or installation labor or any other such costs incurred in obtaining warranty replacements or repair.
  • Page 10 Hayward is a registered trademark and ColorLogic and CrystaLogic are trademarks of Hayward Industries, Inc. © 2016 Hayward Industries, Inc. All other trademarks not owned by Hayward are the property of their respective owners. Hayward is not in any way affiliated with or endorsed by those third parties.
  • Page 11 La mention AVIS fournit des consignes particulières qui sont importantes, mais qui ne sont pas reliées à des risques. Hayward Pool Products Canada 2880 Plymouth Drive, Oakville ON L6H 5R4 Haywardpiscine.ca UTILISEZ SEULEMENT DES PIÈCES DE REMPLACEMENT D’ORIGINE HAYWARD...
  • Page 12 électriques qui y sont associées sont sous tension en tout temps, même lorsque les lumières sont ÉTEINTES! Coupez le courant au disjoncteur principal avant de procéder à l’entretien ou à la réparation des lumières ColorLogic. CONSERVEZ CES INSTRUCTIONS UTILISEZ SEULEMENT DES PIÈCES DE REMPLACEMENT D’ORIGINE HAYWARD...
  • Page 13 LKBUN1000 (requis pour l’utilisation d’une connexion réseau sur courant porteur d’un système de commande Pro Logic de Hayward). Le LTBCY11300 offre trois options de tension de sortie : 12 V, 13 V et 14 V. Spécifications Dimensions du boîtier :...
  • Page 14 • Le transformateur doit être installé au moins 30 cm (1 pi) au-dessus du niveau de la terrasse avec le compartiment de filage vers le bas. • Placez le LTBCY11300 à une distance d’au moins 3 m (10 pi) de l’intérieur du mur de la piscine.
  • Page 15 Connecter directement à une lumière de piscine ou de spa Lorsqu’une lumière de piscine de basse tension sera connectée directement au LTBCY11300, utilisez l’adaptateur pour conduit non métallique et le scellant fournis. Consultez le diagramme ci-dessous. Toute connexion à la barre omnibus doit être serrée à 10 livres pouce.
  • Page 16 à basse tension Pour des renseignements concernant le câblage sur le site, veuillez consulter les informations affichées à l’intérieur du couvert avant du LTBCY11300 ainsi que le diagramme ci-dessous. Transformateur LTBCY11300 de 300 W de Hayward pour alimenter les lumières à...
  • Page 17 à l’air libre du filtre. Ne fermez pas la vanne manuelle de mise à l’air libre du filtre avant qu’un jet d’eau continu ne circule (pas d’air ou un mélange d’air et d’eau). UTILISEZ SEULEMENT DES PIÈCES DE REMPLACEMENT D’ORIGINE HAYWARD...
  • Page 18 électrique et confiez la réparation à un représentant qualifié avant de l’utiliser. MISE EN GARDE – Les pompes HAYWARD sont conçues pour fonctionner avec des piscines installées de façon permanente et peuvent également être utilisées avec un spa, lorsque cela est indiqué. N’utilisez pas cet appareil avec une piscine démontable.
  • Page 19 Pour obtenir un service en vertu de la garantie, veuillez communiquer avec le lieu d’achat ou avec le centre de service Hayward autorisé le plus près. Pour de l’aide concernant le centre de service Hayward le plus près, veuillez visiter le www.haywardpool.
  • Page 20 Hayward is a registered trademark and ColorLogic and CrystaLogic are trademarks of Hayward Industries, Inc. © 2016 Hayward Industries, Inc. All other trademarks not owned by Hayward are the property of their respective owners. Hayward is not in any way affiliated with or endorsed by those third parties.