4 REMOTE CONTROLLER OPERATION

4.1. OPTIONAL LIQUID CRYSTAL REMOTE CONTROL PC-ART
Liquid crystal display (LCD)
MODE
FAN SPEED
VENTI
LOUVER
Model: PC-ART
o
Fan speed indicator
Indicates the ventilation speed selected:
- (High / Medium / Low)
Indicator of Total ventilator
Indicates if the total heat exchanger has been selected.
- A/C
only air conditioning
- VENTI
only ventilation
- A/C + VENTI
if both are selected
p
Operation Mode Indicator
Indicates the operation mode selected:Fan/Cool/Heat/Dry/Auto
(Cool/Heat)
q
Run indicator (Red lamp)
r
RUN/STOP switch
s
MODE (Operation Mode Selection) switch
t
FAN SPEED (Fan Speed Selection) switch
u
Up & down panel operation switch
v
VENTI (ventilator operation) switch
w
LOUVER (deÀ ector panel) switch
x
SELECT (Day/Schedule) switches
Increase and decreases the Day/Schedule for timer operation.
y
ON/OFF TIMER switch
Used to activate or deactivate the timer operation.
z
OK switch
{
RESET (Filter Reset Switch)
After cleaning the air ¿ lter, press the "RESET" button. FILTER
indication will disappear and the next ¿ lter cleaning time is reset. It
also stops the run procedure.
|
TEMP (temperature setting) switches
TIMER
RESET
SCHEDULE
OK
DAY
SELECT
INSTALLATION MANUAL
}
T.RUN (test run indication)
Check (check indication)
These tests appear when TEST RUN or CHECK are being
performed.
~
ABNML (alarm) indicator

SET TEMP (set temperature) indicator
1234S indicator (setting schedule number)

Mon Tue ... Sun indicator (day of the week indicator).
Indicates that central station or CSNet control is operating.
Swing louver indicator
DEFROST indicator
ƒ
SERVICE mode indicator.
Indicates the change to special operations
Time indicator.
Time indicator. (Indicates the programmed time).
the direction of the arrow.

NOTE:
- If the LOW fan speed is selected and the outdoor
temperature is higher than 21°C, the compressor is
subjected to an excessive load when operating in heating
mode.
Therefore, the fan speed should be set to HIGH or
MEDIUM to avoid activating the safety devices.
- When the system is restarted after a shutdown of more
than approximately 3 months, the system should be
checked by your service provider.
- Turn off the main switch when the system is to be
inoperative for a long period of time. Otherwise the system
consumes electricity as the oil heater remains active even
though the compressor is stopped.