V
Adj. condition and cautionary items
(1) Lighting condition in surrounding area
Surrounding lighting should be lower than 10 lux. Try
to isolate adj. area into dark surrounding.
(2) Probe location
- PDP : Color Analyzer (CA-100, CA-100+, CA210)
probe should be firmly attached to the Module
- LCD : Color Analyzer (CA-210) probe should be within
10cm and perpendicular of the module surface
(80°~ 100°)
- In case of LCD, B/L on should be checked using no
signal or Full white Pattern
8-7. Reference
coordinate and color temperature)
Standard color coordinate and temperature using CS-1000
O
Luminance: Full white 216 Gray
O
Standard color coordinate and temperature using CA-210(CH
O
10)
- Gain color coordinate
Pattern : Full white 216 Gray
O
9. 3D Function Test
9-1. 3D Pattern Inspection
(Pattern Generator MSHG-600 or MSPG-6100, HDMI mode
NO. 872 , pattern No. 83)
(1) Please input 3D test pattern like below
(2) When 3D entrance OSD is automatically displayed, Push
the OK key
Copyright ©2011 LG Electronics Inc. All rights reserved.
Only for training and service purposes
(White
Balance
(3) When took off 3D shutter glasses, Check whether viewing
the pattern like below picture)
9-2. 2D TO 3D CONVERT INSPECTION
adj.
(1) Input Combination Pattern like (Fig.1) in HDMI Input
(2) Enter the Swap Button(Yellow Color)
Check the separated line in the SET
* When you enter the swap button. Depth value is set to
Maximum value(20) automatically Worker has to enter the
ETC Key Before using the swap button
9-3. RF Glasses , 3D RF Emitter Check
* Power Only Mode
* MSHG-600 or MSPG-6100
- 10 -
(Fig.1)
LGE Internal Use Only