Sharp AR-LC6 Service Manual page 13

Digital copier/printer/ multifunctional system option large capacity tray
Table of Contents

Advertisement

ADJ 2
Resist amount adjustment
ADJ 2A
Adjustment in the resist amount
adjustment mode
1) Set the resist amount adjustment mode of SIM 51-02 by the key
operation of the machine.
#/P
C
2) In SIM 51-02, the display is shown as follows. The resist amount
adjustment value can be set for each paper feed tray.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-14, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.TRAY1
50
3.TRAY2
50
4.TRAY3
5.TRAY4
50
6.BPT
50
7.LCC
8.ADU
50
9.SPF(TOP)
50
11.SPF(LOW)
50
12.SPF FEED(TOP)
13.SPF FEED(HIGH)
50
14.SPF FEED(LOW)
3) Select "0: TRAY SELECT" and press START key.
The display is shown as follows. Select "6: LCC" as the paper feed
tray, and press START key.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 1-6, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT
6.LCC
(ABOVE+10: DUPLEX MODE)
4) The display is shown as follows again. Select "7: LCC" and press
START key.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-14, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.TRAY1
50
3.TRAY2
50
4.TRAY3
5.TRAY4
50
6.BPT
50
7.LCC
8.ADU
50
9.SPF(TOP)
50
11.SPF(LOW)
50
12.SPF FEED(TOP)
13.SPF FEED(HIGH)
50
14.SPF FEED(LOW)
5) Then enter the adjustment value with 10-key.
(Default: 50, Adjustment range: 0 – 99)
• When the adjustment value is increased by 1, the resist amount
is increased by 1msec.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
7.LCC
6) Enter the adjustment value and press START key, and printing is
started and the set value is stored.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. NOW PRINTING.
7) After completion of the adjustment, press [CA] key to terminate the
simulation mode.
5
1
2
50
1
50
10.SPF(HIGH)
50
50
50
1
50
1
50
10.SPF(HIGH)
50
50
50
50
AR-LC6 ADJUSTMENT 6 - 2
ADJ 2A
Adjustment in the print lead edge
adjustment mode
1) Set the print lead edge adjustment mode of SIM 50-5 by the key
operation of the machine.
#/P
C
2) In SIM 50-5, the display is shown as follows. The resist amount
adjustment value can be set for each paper feed tray.
SIMULATION 50-5
LEAD EDGE ADJUSTMENT. SELECT 0-12, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
(ADJUSTMENT DATA)2.RRCB
50
3.TRAY1
50
4.TRAY2
50
6.TRAY4
50
7.BPT
50
(VOID AREA SETTING) 10.DENA
3) Select "0: TRAY SELECT" and press START key.
The display is as shown below. Select "6: LCC" as the paper feed
tray and press START key.
SIMULATION 50-5
LEAD EDGE ADJUSTMENT. SELECT 1-6, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT
6.LCC
(ABOVE+10: DUPLEX MODE)
4) The display is as shown below again. Select "8: LCC" and press
START key.
SIMULATION 50-5
LEAD EDGE ADJUSTMENT. SELECT 0-12, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
(ADJUSTMENT DATA)2.RRCB
50
3.TRAY1
50
4.TRAY2
50
6.TRAY4
50
7.BPT
50
(VOID AREA SETTING) 10.DENA
5) Then, enter the adjustment value with 10-key.
(Default: 50, Adjustment range: 0 – 99)
• When the adjustment value is increased by 1, the resist amount
is increased by 1msec.
SIMULATION 50-5
LEAD EDGE ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
8.LCC
6) After entering the adjustment value, press START key, and print-
ing is started and the set value is stored.
SIMULATION 50-5
LEAD EDGE ADJUSTMENT. NOW PRINTING.
7) After completion of the adjustment, press [CA] key to terminate the
simulation mode.
5
0
5
2
5.TRAY3
50
8.LCC
50
9.ADU
50
50
11.DENB
30
12.FR VOID
30
1
2
5.TRAY3
50
8.LCC
50
9.ADU
50
50
11.DENB
30
12.FR VOID
30
50

Advertisement

Table of Contents
loading

Table of Contents