Standard Equipment; Countplus Installation; Tool Inspection; Tool And Work Area Set-Up - RIDGID CountPlus Operator's Manual

Cable counter
Table of Contents

Advertisement

SeeSnake CountPlus Cable Counter
Power Source
1 x CR2450 3V coin-style battery
Operating Environment
Temperature
Humidity
Storage

Standard Equipment

Item
CountPlus
SAVE THESE INSTRUCTIONS!
The manuals provided with this instrument must be
kept with the instrument and made available to any
operator of the instrument.

CountPlus Installation

If you are retro-fitting the CountPlus to an existing
SeeSnake unit, you will need to install it. Detailed
instructions are included in Appendix A

Tool Inspection

WARNING
Daily before use, inspect the SeeSnake and the
CountPlus to reduce the risk of serious injury from
electrical shock or physical injuries!
1. With the SeeSnake unplugged from the monitor
unit, inspect the power cord and plug for
damage or modifications. IF any damage or
modification is found, do not use the tool until it
has been properly repaired or replaced.
2. Clean any oil or grease from the SeeSnake,
especially from the frame, to prevent the unit
from slipping from your grip when carrying or
positioning it.
3. Inspect the SeeSnake for any broken, worn or
missing, misaligned or binding parts, or any
other condition which might prevent safe,
normal operation. Make sure the cable drum
rotates smoothly and the cable drum friction lock
4
-4°F to 22°F (-20°C to 50°C)
5% to 95% RH
-4°F to 140°F(-20°C to 60°C)
Cat. #
31753
.
Ridge Tool Company
works correctly. Inspect the cable for any signs
of breakage or extreme wear. Inspect the
camera head connection and ensure it is tight. If
any problems are found, have them repaired
before using the SeeSnake.

Tool and Work Area Set-Up

WARNING
Before use, setup the SeeSnake and work area
safely to reduce the risk of injury from shock, fire,
crushing injuries or other causes and prevent
damage.
1. Check work area for adequate lighting.
2. Check for a stable, level location to firmly
position the SeeSnake where it will be stable
in operation.
3. Do not connect the SeeSnake power cord in
the presence of flammable liquids, vapors, or
dust that may ignite.
4. Ensure there is a clear, level, dry place for
the operator that allows him to operate clear
of the cable.
5. Ensure a clear path to a power outlet that
does not contain any potential sources of
damage to the power cord.
6. Use extension cords only if necessary. Use
only cords rated for outside use and of
sufficient wire size.
Minimum Wire Gauge for Extension Cords
Nameplate
Total Length (in feet)
Amps
0 – 25
0 – 6
18 AWG
6 – 10
18 AWG
10 – 12
16 AWG
12 – 16
14 AWG
26 – 50
51 – 100
16 AWG
16 AWG
16 AWG
14 AWG
16 AWG
14 AWG
NOT
12 AWG
RECOMMENDED