Toshiba PD42W1U Service Manual page 16

42" plasma display
Table of Contents

Advertisement

Panel W/B
Composite/Component signal
1) Set the AV mode and input the white pattern signal from NTSC (or PAL according to the system) signal generator.
2) Press the Menu button twice to access main menu and set the manual W/B to Cool.
3) Access the Panel W/B mode and align the Low Light and High Light shown below by using color meter.
Alignment Item
Brightness
R Cutoff
B Cutoff
B Drive
R Drive
Contrast
4) Record R Cutoff, B Cutoff, R Drive and B Drive setting data.(***Data 3)
***Data 3
Manual W/B
Cool (High)
Normal (Mid)
Warm (Low)
5) Change the Manual W/B to Normal by the Menu button and STR button.
6) Modify the Data as follows.
Increase R Drive 24 steps and reduce B drive 2 steps and B cutoff 1 step from Cool mode.
7) Change the Manual W/B to Warm by the Menu button and STR button.
8) Modify the Data as follows.
Increase R Drive 30 steps and reduce B drive 35 steps, and B cutoff 2 steps from Cool mode.
9) Access the SG Hold mode (Forced signal system set mode) and set the system to NTSC (or PAL).
10) Return to the Panel W/B mode and copy the Data 3 for each item.
11) Repeat item 9) and 10) for SECAM system.
Equipment
NTSC (or PAL according to the system)
signal generator Color meter
Cool (High)
Normal (Mid)
Warm (Low)
Reference Cool (Hi)
71
10cd/m
7F
Set to 15% signal level by the generator.
7D
Set 15% signal level by the generator.
75
Set 75% signal level by the generator.
62
Set 75% signal level by the generator.
84
Optimum setting
R Cutoff
x
y
0.272
0.290
0.288
0.296
0.313
0.329
Setting/Special feature
by 15% signal level (Set by generator)
2
B Cutoff
B Drive
- 16 -
R Drive

Advertisement