3M Bair Hugger 775 Operator's Manual

3M Bair Hugger 775 Operator's Manual

Temperature management unit
Hide thumbs Also See for Bair Hugger 775:

Advertisement

1   T emperature management unit
Model 775 Operator's manual
U nité de contrôle de température,
2  
Modèle 775 Manuel de l'utilisateur
T emperaturmanagementgerät
3  
Modell 775 Benutzerhandbuch
U nità per la gestione della
4  
temperatura Modello 775
Manuale d'uso
U nidad de control de temperatura,
5  
Modelo 775
Manual del operador
M odel 775 temperatuurregelunit
6  
Gebruikershandleiding
T emperaturregleringsenhet,
7  
Modell 775 Bruksanvisning
T emperaturstyringsenhed Model
8  
775 Brugervejledning
To t a l Te m p e r a t u r e M a n a g e m e n t
3
Bair Hugger
Temperature Management Unit
Model 775
Operator's Manual
T emeraturadministrasjonsenhet
9  
Modell 775 Brukerhåndbok
L ämpötilan valvontayksikkö edestä
0  
Malli 775 Käyttöopas
Unidade de Gestão
- 
de Temperatura Modelo 775
Manual do Utilizador
Μ ονάδα Διαχείρισης
=  
Θερμοκρασίας Μοντέλο 775
Εγχειρίδιο Χρήσης
D muchawa Model 775 Instrukcja
H  
obsługi
H őmérséklet szabályozó egység
J  
775-ös Modell Használati utasítás
Termoregulační jednotka, Model
F 
775 Návod k obsluze
T emperatūros kontrolės įrenginys,
Q  
Modelis 775 Naudotojo vadovas
Устройство управления
M 
температурой, модель 775
Руководство по эксплуатации
:   Ç alıştırma
El Kitabı
Vücut Isısı Yönetim Ünitesi
Model 775
ベアーハガー 体温管理装置
E  
モデル775 取扱説明書
775 型温度管理仪 操作员手
I 
U 
S y s t e m

Advertisement

Table of Contents
loading

Summary of Contents for 3M Bair Hugger 775

  • Page 1 Bair Hugger ™ Temperature Management Unit Model 775 Operator’s Manual 1   T emperature management unit T emeraturadministrasjonsenhet Устройство управления 9   M  Model 775 Operator's manual температурой, модель 775 Modell 775 Brukerhåndbok Руководство по эксплуатации U nité de contrôle de température, 2  ...
  • Page 3 Bair Hugger Temperature Management Unit Model 775 Operator’s Manual English Français Deutsch Italiano Español Nederlands Svenska Dansk Norsk Suomi Português Ελληνικά Polski Magyar Česky Lietuvių Kalba Русский Turkish 日本語 英语...
  • Page 5: Table Of Contents

    Table of Contents Introduction  � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �  DescriptionoftheTotalTemperatureManagement System �...
  • Page 7: DescriptionOfTheTotalTemperatureManagement Tm System

    Bair Hugger brand Total Temperature Management system consists of a Model 775 forced-air temperature management unit (with optional rolling stand, and other accessories) and disposable components, including Bair Hugger forced-air blankets, 3M Bair Paws patient warming gowns and the 3M blood/fluid warming set.
  • Page 8: Cautions

    Bair Hugger Model 775 Temperature Management Unit Operator’s Manual Do not continue temperature management therapy if the Over-temp indicator light illuminates and the alarm sounds. Thermal injury may result. Unplug the unit, and contact a qualified service technician. Do not continue 241 blood/fluid warming therapy if the Over-temp indicator light illuminates and the alarm sounds.
  • Page 9: Notices

    Bair Hugger Model 775 Temperature Management Unit Operator’s Manual Electrical shock hazard. Do not disassemble the temperature management unit unless you are a qualified service technician. There are electrically live parts within the unit when it is connected to a power source, even when the unit is in Standby mode. Notices The Bair Hugger temperature management unit meets medical electronic interference requirements.
  • Page 10: OverviewAndOperation

    Bair Hugger Model 775 Temperature Management Unit Operator’s Manual Overview and Operation Alphanumeric IV pole clamp Carrying handle display Hose Control Panel Hose connection Power cord connection Figure A. Model 775 temperature Figure B. Model 775 temperature management unit – front view management unit –...
  • Page 11: OverviewOfControlPanel

    Bair Hugger Model 775 Temperature Management Unit Operator’s Manual Overview of Control Panel Temperature Modes Alphanumeric Display High Fan 43 ˚C Setting Low Fan Setting Model 775 TEMP IN RANGE AMBIENT FAULT OVER TEMP STANDBY Figure C. Model 775 temperature management unit control panel alphanumeric display The alphanumeric display shows the temperature at the Bair Hugger blanket or Bair Paws gown end of the temperature management unit hose in degrees Celsius.
  • Page 12 Bair Hugger Model 775 Temperature Management Unit Operator’s Manual standby Upon power up, the warming unit defaults to Standby and the high fan setting. When the unit is in 32˚C (Low), 38˚C (Med), or 43˚C (High) or Ambient mode, press the Standby button to place the unit in Standby mode.
  • Page 13: MountingTheTemperatureManagementUnitToAnIvPole

    Bair Hugger Model 775 Temperature Management Unit Operator’s Manual Mounting the Temperature Management Unit to an IV Pole caution To prevent tipping, clamp the Model 775 temperature management unit to an IV pole at a height that provides stability. We recommend clamping the unit no higher than 44" (112 cm) from the floor on an IV pole with a minimum 28"...
  • Page 14: InstructionsForUse

    Bair Hugger Model 775 Temperature Management Unit Operator’s Manual Instructions for Use The instructions below describe how to operate the Model 775 temperature management unit. For information about using Bair Hugger blankets, Bair Paws gowns, or the 241 blood/fluid warming set with the Model 775 unit, refer to the Instructions for Use included with each of these disposable components.
  • Page 15: ViewingTheTemperatureModeTimer

    Bair Hugger Model 775 Temperature Management Unit Operator’s Manual Viewing the Temperature Mode Timer The temperature mode timer records the amount of time the temperature management unit has been operating in the selected temperature mode. The timer resets itself every time you select a different temperature mode.
  • Page 16: GeneralMaintenance

    Bair Hugger Model 775 Temperature Management Unit Operator’s Manual General Maintenance Cleaning the Cabinet and Hose warning Do not immerse the cabinet or hose while cleaning. Moisture will damage the components, and thermal injury may result. precautions • Do not use a dripping wet cloth to clean the cabinet. Moisture may seep into the electrical contacts and damage the components.
  • Page 17: TechnicalServiceAndOrderPlacement

    Bair Hugger Model 775 Temperature Management Unit Operator’s Manual Technical Service and Order Placement Technical Service germany TEL: +1-952-947-1200 TEL: +49-4154-9934-0 +1-800-733-7775 FAX: +49-4154-9934-20 FAX: +1-952-947-1400 united kingdom france TEL: +44-1924-200-550 TEL: +33-4-42-98-14-00 FAX: +44-1924-200-518 Indigo (in France only): 0-820-33-90-40 FAX: +33-4-42-98-14-01 rder lacement...
  • Page 18: Specifications

    Bair Hugger Model 775 Temperature Management Unit Operator’s Manual Specifications Physical Characteristics dimensions 13" high x 13" deep x 14" wide 33 cm high x 33 cm deep x 36 cm wide weight 16 lb (7.3kg) relative noise level 53 dBA (High fan setting) 48 dBA (Low fan setting) hose Flexible, compatible with the Bair Hugger brand 241...
  • Page 19 Bair Hugger Model 775 Temperature Management Unit Operator’s Manual Electrical Characteristics heating element 1400 W Resistive leakage current Meets UL 60601-1 and IEC 60601-1 requirements. blower motor Operating speed: 4,700 rpm (high fan setting), 4,100 rpm (low fan setting) Airflow: up to 48 cfm or 23 L/s power consumption Peak: 1550 W Average: 800 W...
  • Page 20: DefinitionOfSymbols

    Bair Hugger Model 775 Temperature Management Unit Operator’s Manual Definition of Symbols The following symbols may appear on the product’s labeling or exterior packaging. Equipotentiality plug (ground) Fuse Attention, consult appropriate documents Nonexplosion proof Dangerous voltage Type BF equipment (patient applied) Voltage, alternating current (AC) Special refuse, discard separately Protective earth ground...
  • Page 21 Made in the USA by Arizant Healthcare Inc. 3M is a trademark of 3M Company, used under license in Canada. ARIZANT HEALTHCARE, BAIR HUGGER, 241, BAIR PAWS, TOTAL TEMPERATURE MANAGEMENT, and the BAIR HUGGER logo are trademarks of Arizant Healthcare Inc., used under license in Canada.

Table of Contents