Important Safety Information Read the iN-Command Manual, and these warnings and instructions carefully before using this product. Failure to follow the use instructions in this owner’s manual, or improper use of the Mobile Application, Display Commander and/or Body Control Module, could result in personal injury, including death.
JRVCS105 • TABLE OF CONTENTS TABLE OF CONTENTS ............3 MOBILE DEVICES: ..................19 INTRODUCTION ..............4 Pairing Mobile Device to DC ............... 20 Thank You! ................4 Setting the Floor Plan on the Mobile Device ..........22 Features .................4 CHECKING FOR AN ACTIVE BLUETOOTH SESSION ......23 Precautions ................4...
• Use Recommended Accessories. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK AND Thank you for choosing iN-Command. We hope you will find the instruc- ANNOYING INTERFERENCE, USE ONLY THE RECOMMENDED tions in this owner’s manual clear and easy to follow. If you take a few ACCESSORIES.
• Route power and transmit wires through the hole and connect • Tools and Supplies • Check and ensure correct operation You will need these tools and supplies to install your JRVCS105: • Mount the unit using four #8 PH (0.164” x 0.75”) screws • Phillips screwdriver •...
JRVCS105 • WIRING The wiring diagram depicts all the wiring connections required for proper operation of the unit. The TX (transmit) and RX (receive) wires from the BCM to DC are reversed at each device (the BCM transmits and the DC receives, and vice versa).
JRVCS105 • SETUP MENU LIST ITEM SELECTION Tanks, light groups, and motor functions can be added or removed. Black Water Tank 2 No, Yes Motor functions may include slides, awnings, jacks, or any motor Gray Water Tank 2 No, Yes that may be controlled with a momentary switch.
JRVCS105 • SAFETY LOCKOUT IN-Command is equipped with a Safety Lockout feature to ensure certain system functions are unavailable during transit. When the Brake or Right Turn Signal on the tow vehicle is activated, IN-Command will lock down all motorized functions.
JRVCS105 • TROUBLESHOOTING Symptom Solution Press Reset Button on BCM Check main fuse in Distribution Panel. Display Commander (DC) will not turn ON or the touch screen will not function Check 12V+ on wire to DC (RED wire). Check Ground wire to DC.
JRVCS105 • OVERRIDE SWITCHES The Body Control Module has an override switch and knob. The knob below the switch corresponds to a motor function made by the Display Commander and Handheld Devices App. The switch and knob actuate all the motor functions on the RV.
This equipment generates, uses and can radiate radio frequency energy and, if not installed JRVCS105 System and used in accordance with the instructions, may cause harmful EPROM Non-Volatile Memory ..... . YES interference to radio Bluetooth Version .
JRVCS105 • PASSCODE PROTECTION A passcode is required to access the system. On first using the system, you are required to enter and confirm a new passcode. Confirm the new passcode.
• Connect devices with Bluetooth • Change the passcode • Reset the floor plan • View IN-Command’s Legal documents and customer support information. The Setup button is used by the manufacturer. 3. A device rename window will open. Press “OK” after completing the text editing.
JRVCS105 • Tanks • Scroll List Editing Black water tanks, and Gray water tanks can be added to the system. 1. Push the “Pages” button twice. 2. Press and hold the “≡” icon before the device name and • Lights drag to move the device to a new location, “Motor 1”...
JRVCS105 • Passcode 1. Push the “Pages" button twice. 3. To change Passcode you will need to enter the current passcode. 2. Press “ ” to enter passcode setup.
JRVCS105 • Set Passcode Timer Press the “Set Timer” button to select the idle time to 3. Confirm new passcode. activate the passcode protection. • Change Passcode • Clear Passcode 1. Press the “Change Passcode” button to change to a Press the “Clear Passcode”...
JRVCS105 • MOBILE DEVICES: IN-Command is able to pair to Android and iOS devices using the iN-Command App. Visit the Google Play and Apple App stores on your mobile device to download and use the iN-Command App. Seven mobile devices are able to be paired IN-Command at one time, but only 1 iOS and 3 Android devices are able to be actively paired at the same time;...
JRVCS105 • Pairing Mobile Device to DC 1.3 Or press “Discover” for the DC to become “visible” to other devices 1. On the DC: for 300 seconds. Press “Allow”. 1.1 Push the “Pages” button 2 times. 1.2 Select “ ”. Press “Scan” to start scanning for...
Page 22
JRVCS105 2. On the Mobile Device: 2.2 The Mobile APP will scan for the DC 2.3 The DC will be displayed in the Unpaired 2.1 Press “Bluetooth” on the “Setup” device. Devices list in the format “JENSENDCXXXXXX”. page to find the DC device.
JRVCS105 • Setting the Floor Plan on the Mobile Device 3.1 On the DC, a request message will appear. Press “Pair” 1.1 After Pairing the mobile Device, go to the settings menu on that to start the BT pairing and concurrently accept the device and select “Reset”.
JRVCS105 • CHECKING FOR AN ACTIVE BLUETOOTH SESSION 1. Push the “Pages” button 2 times and select the connections, or “ “, menu. This page shows the current Actively Paired handheld devices. To disconnect a handheld device, press “Disconnect”, or simply shut down the device’s app.
JRVCS105 • SOFTWARE UPDATE* 3. The Settings menu will appear. Software updates include floorplan redesigns and app version updates. Insert USB drive with software update into the USB port located underneath the bottom right corner of the DC. The system will look for specific file names for software updates.
Page 26
JRVCS105 7. Press the APP Version “Update” button to update DC APP. 5. Press OK to continue. 8. Press the Floor Plan “Select” button to select and load the new floor plan. 6. Press the BCM Version “Update” button to update the BCM firmware.
JRVCS105 2. Select one of the two options to restore to a previous state. • RESET: FLOOR PLAN Current settings will be lost. To reset the floor plan, removing customizations, press the - Floor Plan: restore to previous floor plan setting.
JRVCS105 • SYSTEM CALIBRATION* 3. Enter admin passcode to proceed.** 1. Push the “Pages” button 2 times and select the Settings Menu. Enter the Engineer Passcode.** 2. Scroll to the bottom of the page and select “Admin”. 4. Select the device that needs to be calibrated.
Page 29
JRVCS105 7. To calibrate the Touch Screen, select “Set”. Follow the instructions. 5. Select “Tanks” to set resistor reference value for every The DC will restart after calibration. tank. *The system should be calibrated by the manufacturer and only need 6.
Need help?
Do you have a question about the JRVCS105 and is the answer not in the manual?