Disassembling the Body Cover
(1)
Remove the harness of the tape end sensor ASSY from the groove of the body cover.
(2)
Remove two screws and remove the tape end sensor ASSY.
(3)
Remove the sensor PCB ASSY from the hooks of the body cover in two places bowing the
cover toward outside.
Tape end sensor ASSY
Fig. 3.1-10 Removing the Tape End Sensor ASSY and Sensor PCB ASSY
(4)
Remove two screws from the cassette cover bracket and remove the cassette cover bracket
along the arrow direction.
Cassette cover bracket
Screws
Groove
Body cover
Fig. 3.1-11 Removing the Cassette Cover Bracket