  • Page 1 /STOP PROGR AM START DOWN POW ER DFW-150/250 deluxe food warmer owner’s manual Manufacturing Numbers: 9100109, 9100120, 9100160, 9100164, 9100190, 9100805 www.ajantunes.com P/N 1010966 Rev. G 08/12...
  • Page 2: Table Of Contents

    Your Deluxe Food Warmer (steamer) is manu- Fault Codes ..........8 factured from the finest materials available Diagnostic LEDs ........8 and is assembled to Roundup’s strict quality Date of Purchase Daily Maintenance ......... 8 standards. This unit has been tested at the Monthly Maintenance ......
  • Page 3: Important Safety Information

    IMPORTANT SAFETY WARNINGS INFORMATION • The following tips are recommended Be advised of the following warnings when operating and performing maintenance on for maintenance of your stainless steel Use the following guidelines for safe opera- equipment: this unit. tion of the unit. • Always use soft, damp cloth for • If the supply cord is damaged, it must • Read all instructions before using...
  • Page 4: Specifications

    SPECIFICATIONS SHIPPING WEIGHT DFW-150 Models 40 lbs (18.2 kg) DFW-250 Models 40 lbs (18.2 kg) CAPACITIES DFW Series 2-7/8” (73 mm) deep half-size steam table pan Model & Width Depth Height Mfg. No. DFW-150 9100109 16 1/2" 17 1/8" 9"...
  • Page 5: Installation

    INSTALLATION WARNING Top Cover False NOTE: When placing the unit, make sure Be sure to follow all the precautions, proce- Bottom to provide at least 3 inches of space on dures, and safety steps listed in the Important all sides of the unit. Safety Information section of this manual.
  • Page 6: Plumbing

    Water Pressure Regulator Inlet Hose & Strainer & Strainer Assy. (P/N 7000314) Assy. (Supplied) Figure 2. Connecting Water Supply to DFW-250 3. Turn the water valve on. PLUMBING 4. Over a bucket, press and hold DFW models are designed to use cold tap the white plastic tip on the Quick water.
  • Page 7: Operating Instructions

    9100160 45 sec. 0 min. make sure the control is in PROGRAM 5. Remove steamed product. mode, then press and hold both ▲ DFW-250 2 min., 15 sec., 0_50 and ▼ simultaneously for 1-2 seconds 9100164 45 sec.
  • Page 8: Hi-Limit Reset Button

    “ERR” 2. Check the water pressure regulator fault code. If this fault code appears, you gauge (DFW-250 only) and verify must clear these settings using the following that it reads 20–25 psi (1.4–1.7 kg/ procedure.
  • Page 9: Monthly Maintenance

    Top Cover False Bottom Gasket Pan Diffuser Spray Tube Tank Asssembly Cover Figure 5. Components MONTHLY MAINTENANCE 6. Use a scraper or spatula to remove the Seasoning mixture consists of 3/4 ounces (25 excessive calcium/mineral buildup from ml/25 cc) baking soda, 3/4 ounces (25 ml/25 CLEAN SPRAY TUBE AND STEAM the generator surface (Figure 6).
  • Page 10 Spare O 6. Fill the water tank and test the unit. Rings (3) O-ring Tubing O Ring WATER STRAINER (DFW-250 ONLY) Male Quick The water strainer protects your equipment Mesh Disconnect Screen from any foreign debris in the water line that...
  • Page 11: Troubleshooting

    TROUBLESHOOTING WARNING To avoid possible personal injury and/or damage to the unit, inspection, test, and repair of electrical equipment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required. Use extreme care during electrical circuit tests.
  • Page 12 TROUBLESHOOTING (continued) Problem Possible Cause Corrective Action Unit heats but there is little or no Filter Strainer and/or Spray Tube is restricted. Check and clean the Filter Strainer and Spray Tube steam as described in the Maintenance section of this produced manual.
  • Page 13: Replacement Parts

    REPLACEMENT PARTS Dual Water Pressure Regulator Kit - Part No. 7000235 Item Part No. Description Qty. To Steamer 7000139 Elbow, Quick To Steamer Disconnect - 1/4” 2030126 Tubing 1/4” I.D. PVC BRD. 24” Long 2030125 Tubing 1/4” I.D. PVC BRD. 12” Long 2040150 Elbow, Male - Nylon 2 1/4”...
  • Page 14 REPLACEMENT PARTS (continued) P/N 1010966 Rev. G 08/12...
  • Page 15 26 0502719 Hinge Base 48 7000170 Check Valve Kit, 0505726 Access Cover Assy. 27 060P125* Spring Discharge & Intake (DFW-250 only) 28 0020952 Hinge Beam 49 7000156 Audio Alarm Kit 0010145 Spray Tube Assembly 1 29 0502722 Pivot Bracket 50 0503333 Bracket, Temperature 1...
  • Page 16 REPLACEMENT PARTS (continued) Inset A See Inset B (Mfg. # 9100120 only) See Inset A Inset B – Self-Contained Water Tank Inset B – Direct Water Hook-Up P/N 1010966 Rev. G 08/12...
  • Page 17 26 0502719 Hinge Base 48 7000170 Check Valve Kit, 0505726 Access Cover Assy. 27 060P125* Spring Discharge & Intake (DFW-250 only) 28 0020952 Hinge Beam 49 7000156 Audio Alarm Kit 0010145 Spray Tube Assembly 1 29 0502722 Pivot Bracket 50 0503333 Bracket, Temperature 1...
  • Page 18: Wiring Diagram

    WIRING DIAGRAM P/N 1010966 Rev. G 08/12...
  • Page 19: Notes

    NOTES P/N 1010966 Rev. G 08/12...
  • Page 20: Limited Warranty

    2. Roundup reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations. Changes to update equipment do not con- stitute a warranty charge.