Reverse osmosis replacement cartridge

Advertisement

Performance Data Sheet Profile™ Reverse Osmosis System Models: PXRQ15FBL, PXRQ15RBL, PNRQ15FBL, PNRQ15RBL, PN-
RQ20FBL, PNRQ20FWW, PNRQ20FBB, PNRQ20FCC, PNRQ21LBN, PNRQ21LRB, PNRQ20RBL, PNRQ21RBN, and PNRQ21RRB.
Ficha Técnica del Funcionamiento de Profile™ en Modelos con Sistema de Ósmosis Inversa : PXRQ15FBL, PXRQ15RBL, PNRQ15F-
BL, PNRQ15RBL, PNRQ20FBL, PNRQ20FWW, PNRQ20FBB, PNRQ20FCC, PNRQ21LBN, PNRQ21LRB, PNRQ20RBL, PNRQ21RBN, y
PNRQ21RRB.
System tested and certified by NSF Inter-
national against NSF/ANSI Standard 42
and against NSF/ANSI Standard 58 for the
reduction of substances as listed below ac-
cording to Standard 42 and 58
Capacity 11.15 gpd (gallons per day) 42.2 lpd (liters per day).
Capacidad: 11,15 galones por dia (42,2 Litros por dia)
Average
Substance Reduction/
Influent/
Reducción de
Promedio
contaminantes
influyente
Chlorine Taste and Odor/
2.0 mg/L
Cloro sabor y olor
Nominal Particulate
70,333 pts/mL
μm / Partículas Nominales
micras
Arsenic (pentavlent)/
0.032 mg/L
Arsénico (pentavalente)
Asbestos/ Amianto
136 fibers/L
Barium/ Bario
9.6 mg/L
Cadmium/ Cadmio
0.028 mg/L
Chromium/ Chromo
0.28 mg/L
(Hex.)
Chromium/ Chromo
0.32 mg/L
(Tri.)
Copper/ Cobre
2.9 mg/L
Cyst/ Quistes
140,000 cysts/L
Lead / Plomo
0.14 mg/L
Radium/ Radio 226/228
25 pCi/L
Selenium/ Selenio
0.1 mg/L
TDS
760 mg/L
Turbidity/ Turbiedad
11 NTU
Operating Specifications/Especificaciones de Funcionamiento
Inlet Pressure/ Presión de Entrada
Inlet Temperature/ Temperatura de Entrada
Maximum TDS Level/ Nivel Máximo de TDS
Maximum Hardness @ 6.9pH/ Dureza Máxima de 6.9pH
Maximum Chlorine/ Nivel Máximo de Cloro
pH Range/ Rango de pH
Daily Production Rate/ Índice de Producción Diaria
Efficiency Rating(3)/ Promedios de Eficiencia (3)
Recovery Rating(4)/ Promedios de Recuperación (4)
Notes:
(1)Tested by NSF International per NSF/ANSI Standard 58 or NSF/ANSI
Standard 42.
(2)NTU is Nephelometric Turbidity Units
(3)Efficiency rating means the percentage of the influent water to the system
that is available to the user as reverse osmosis treated water under operat-
ing conditions that approximate typical daily usage.
(4)Recovery rating means the percentage of influent water to the membrane
portion of the system that is available to the user as reverse osmosis
treated water when the system is operated without a storage tank or when
the storage tank is bypassed.
Sistema controlado y certificado por NSF In-
ternational contra el Estándar 42 y contra el
Estándar 58 de NSF/ANSI para la reducción
de las sustancias que figuran a continuación,
de acuerdo con los Estándares 42 y 58.
Reducción de la Contaminación Deteminada por la evaluación del NSF
NSF specified Challenge
Concentration/
Reduction/
Concentración Máxima
% Promedio
Especificada por NSF
de Reducción
2.0 mg/L ± 10%
At least 10,000 particles/
mL/ Por lo menos10,000
partículas/mL
0.050 mg/L ± 10%
10
to 10
fibers/L; fibers
7
8
greater than 10μm / 10
a 10
7
8
fibras/L; fibras superiores a
10 mg/L
± 10%
0.03 mg/L ± 10%
0.3 mg/L ± 10% (added as
hexavalent)/
(agregado como trivalente)
0.3 mg/L ± 10% (added as
triavalent)
3.0 mg/L + 10%
Minimum 50,000 cysts/L
0.15 mg/L + 10%
25 pCi/L ± 10%
0.10 mg/L ± 10% (added as ½
selenite and ½ selenate)
(agregado como ½ selentio et
½ selenato)
750 mg/L + 40 mg/L
11 ± 1 NTU
40-120 psig (2.8-7.0 kg/cm2)
40-100 F° (5-38° C)
2000 mg/L
10 grains per gal. (171 mg/L)
2.0 mg/L
Models: PNRQ20FBL, PNRQ20FWW, PNRQ20FBB, PNRQ20FCC, PN-
RQ21LBN, PNRQ21LRB, PNRQ20RBL, PNRQ21RBN, and PNRQ21RRB.
4 – 10
13.16 GPD (49.8 L/day)
12.75%
23.14%
Contaminant Reduction Determined by NSF testing.
Average Product
Avg %
Water Concentration/
Promedio de
Concentración del
Agua Procesada
97.5%
0.05 mg/L
99.9%
23 pts/mL
98.1%
0.006 mg/L
99.9%
96.8%
0.310 mg/L
98.9%
0.0003 mg/L
97.2%
0.008 mg/l
96.7%
0.01 mg/l
99.1%
0.027 mg/L
99.99%
3 cyst/L
99.1%
0.001 mg/L
80.0%
5 pCi/L
97.6%
0.002 mg/L
94.5%
42 mg/L
99.1%
0.1 NTU
The concentration of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible limit for water
leaving the system as specified in NSF/ANSI Standard 58.
La concentración de las sustancias indicadas en el agua que ingresa al sistema
fue reducida a una concentración inferior o igual al límite tolerable de agua que
puede dejar el sistema, de acuerdo con lo especificado en el Estándar 58 de
NSF/ANSI.
Notas:
(1)Evaluado por NSF Internacional de acuerdo con el Estándar 58 de NSF/
ANSI o el Estándar 42 de NSF/ANSI..
(2)NTU (Nephelometric Turbidity Units) significa Unidades de Turbidez Ne-
felométrica.
(3Promedio de eficiencia se refiere al porcentaje del agua entrante al sistema
que está disponible para el usuario como agua tratada por ósmosis inver-
sa, de acuerdo con condiciones de funcionamiento típicamente adecuadas
en el uso diario.
(4)Promedio de recuperación se refiere al porcentaje de agua entrante a
la parte de la membrana del sistema que está disponible para el usuario
como agua tratada por ósmosis inversa, cuando el sistema es operado sin
un tanque de almacenamiento o cuando se aplica al tanque de acumula-
ción una circulación alternativa.
2
Contaminant Reduction Determined by
NSF testing.
Reducción de Contaminantes
Determinada por la evaluación de NSF.
Max Permissible
NSF Reduction
Product Water
Requirements/
Concentration/
Requisitos de
Concentración Máxima
Reducción de
Autorizada Aceptable
NSF
de Agua Procesada
N/A
N/A
0.010 mg/L
N/A
NA
99%
2.00 mg/L
N/A
0.005 mg/L
N/A
0.1 mg/L
N/A
0.1 mg/L
N/A
1.3 mg/L
N/A
N/A
0.010 mg/L
N/A
5 pCi/L
N/A
0.05 mg/L
N/A
187 mg/L
N/A
0.5 NTU
N/A
Models: PXRQ15FBL, PXRQ15RBL,
PNRQ15FBL, and PNRQ15RBL.
4-10
8.46 GPD (32.0L/day)
9.05%
19.84%
NSF Test
Report/
Informe de
Evaluación
de NSF
J-00137933
J-00147439
J-00122054
J-00122066
J-00122055
J-00122059
J-00122054
J-00122055
J-00122061
J-00122065
J-00122059
J-00122055
J-00122057
J-00122067
J-00122064