Kenwood KRF-V8010D Service Manual page 15

Hide thumbs Also See for KRF-V8010D:
Table of Contents

Advertisement

www.freeservicemanuals.info
A
B
TUNER UNIT
(X05-482X-XX) 2-70: KRF-V8010D(E,T,X) 3-81: KRF-V8010DW(Q)
1
2
(E,T,X) TYPE
A1 (W02-2584-05)
RF AMP
C1
C2
C4
1
27P
15P
0-5P
C6
ANT1
L2
10P
2
GND
3
D1
3
GND
4
GND
FET1 : 2SK302
TR1
: 2SC2714
TR2,3
: 2SC2413
D1-4
: SVC220 or
KV1440
(Q) TYPE
A1 (W02-2586-05)
4
J1
RF AMP
C1
C2
C4
1
1
27P
27P
0-5P
C6
FM 75
10P
ANT1
L2
2
2
GND
D1
3
3
GND
GND
AM
4
GND
4
5
VT
FET1
: 2SK302
TR1
: 2SC2714
TR2,3
: 2SC2413
5
D1-4
: HVM25 or SVC208
D5
: HSU277 or 1SS356
E1
IC1
:
LA1837
D1
:
DA204U or
IC2
:
LC72131
MA143A or
1SS302
Q1,6,7
:
2SC4081(R,S) or
D3
:
MTZJ8.2(B) or
2SD1819A(Q,R)
HZS8.2N(B2)
Q2,12,14 :
2SA1576A(R,S) or
D4
:
MTZJ5.1(B) or
2SB1218A(Q,R)
HZS5.1N(B2)
Q10,11
:
2SD1757K
D5
:
MTZJ2.7(B) or
HZS2.7N(B2)
A1
:
D8,11,13
:
MA111
6
D9
:
MTZJ3.3(B) or
HZS3.3N(B2)
The DC voltage is an actual reading measured with a high impedance type volt-
meter as the AM/FM signal generator is specified to the conditions as shown in the
list below. The measurement value may vary depending on the measuring instru-
ments used or on the product. The value shown in ( ) is actual reading measured in
the AM made.
MODULATION
MODE
CARRIER
FREQUENCY
FM
98MHz
1kHz
STEREO 67.5kHz 7.5kHz(Pilot)
7
AM
1000(999)kHz
400Hz
MONO 30% MOD
C
D
C40 2P
L9
10uH
D1
R42
R41
10K
100K
L1
L2
1uH
FM FRONT END
MIX
DISTORTION(ST)
VT
5
IFT
TR1
R4
C9
IF-OUT
7
0-100
5P
FET1
R5
R11
100
0-100 VCC
6
C23 OSC
8
TR2
100P
C19
OSC
8P
TR3
OSC
BUFFER
FM FRONT END
MIX
DISTORTION(ST)
IFT
TR1
R4
C9
IF-OUT
7
0-100
5P
FET1
R5
R11
100
0-100 VCC
6
C23
OSC
8
100P
TR2
C19
OSC
10P
TR3
OSC
BUFFER
KRF-V8010D (X05-4932-70)
DESTINATION
W58,
UNIT No.
A1
86
COUNTRY
ABB.
EUROPE
E
U.K.
T
2-70
NO
W02-2584-05
AUSTRALIA
X
KRF-V8010DW (X05-4933-81)
DESTINATION
W58,
UNIT No.
A1
86
COUNTRY
ABB.
RUSSIA
Q
3-81
YES
W02-2586-05
SIGNAL LINE
GND LINE
+B
+B LINE
-B LINE
B
ANT INPUT
DEVIATION
CAUTION: For continued safety, replace safety critical components only with manufacturer's recommended parts (refer to
60dB
parts list).
indicates safety critical components. For continued protection against risk of fire, replace only with same type
and rating fuse(s). To reduce the risk of electric shock, leakage-current or resistance measurements shall be carried out
60dB
(exposed parts are acceptably insulated from the supply circuit) before the appliance is returned to the customer.
E
F
CN2
1
2
FM
+
TUNED
+
C24
330P
R25
C26
27K
0.018
+
REG
AM
AM
AM
ALC
OSC
MIX
RF.AMP
BUFF
AGC
DET
AM IF
SD
COMP
AM
S-METER
FM
AM/FM
S-CURVE
S-METER
IF-BUFF
TUNING
STEREO
DRIVE
DRIVE
FM
FM IF
DET
GND
VCC
L3
C81
8.1V
1
+
(8.1V)
+B
C76
47P
IF AMP
+B
C5
6.6V
0.01
R11
22
6.0V
Q2
1.6V
R87
R1
C1
Q1
1M
100
0.022
C84
0.022
CF2
1.0V
1.2V
+
CF1
R44
+
270
+B
1/4W
R51
5.6K
+
+
+
PLL
2.5V
0.9V
IC2
1/2
REFERENCE
PHASE DETECTOR
DIVIDER
CHARGE PUMP
SWALLOW COUNTER
12bits PROGRAMABLE
1/16,1/17 4bits
DIVIDER
POWER
UNLOCK
ON
DETECTOR
RESET
2
C B I/F
DATA SHIFT REGISTER LATCH
UNIVERSAL COUNTER
X1
7.2MHz
C44
470P
Published in Heiloo, Holland.
G
H
R35
+
+
Q7
100
IC1
FM, MPX
C37
R33
10u10
1K
AM SYSTEM
+
4.4V
C38
2.8V
(4.4V)
10u10
(2.8V)
+
DECODER
ANTI-BIRDIE
P-DET
STEREO
SW
MUTE
VCO
FF
FF
FF
PILOT
304kHz
38k
19k
2
19k
8
DET
7.0V
(4.0V)
C17
+
+
Q6
1u50
+
R38
+
1K
L4
L5
+
R81
150
+B
1W
R84
1K
L6
+B
L7
+B
10.9V
FM +B
Q14
+B
3.4V
11.0V
R59
T. MUTE
1.2K
10.3V
DRIVE
C86
470P
W86
R48 1K
6
R47 1K
5
R46 1K
4
R45 1K
3
KRF-V8010D/V8010DW
Y05-3822-70
I
12/21/15
J
CN1
15
DET
14
S-LEVEL
13
SD
12
STEREO
11
Rch
C83
0V
Q10 MUTE
100P
10
GND
X09-A/3
-CN9
0V
-2.2V
3/4
9
Lch
A
C71
8200P
+15V
8
+15V
0V
R74
47K
W4
15V
7
-15V
-2.2V
Q11
6
T. MUTE
4
PLLDATA
0V
5
5
4
PLLCLK
3
3
PLLCE
6
2
PLLDO
MONO
1
3.5V
Q12
R76
1.8K
2.8V
R77
1K
W58
KRF-V8010D(E) (1/4)
KRF-V8010DW(Q) (1/4)

Hide quick links: