Operating Instructions; Control Panel - Westinghouse WHT401BR User Manual

Tower heater
Table of Contents

Advertisement

SET UP & USE

OPERATING INSTRUCTIONS

CONTROL PANEL

1. Power ON: When powered on for the first time, the buzzer makes a long sound
and then enters into Standby state.
Press (POWER) button (or press remote controller (POWER) button) to turn
on the product and enter into High Mode, the LED displays the current room
temperature.
2. Work Level
S/N
Operation method
S/N
Operation method
S/N
Operation method
S/N
Operation Method
Under standby state, press
Under standby state,
Under standby state, press
Under standby state, press
(POWER) button or press
(POWER) button or press
press the POWER
(POWER) button or press
1
remote controller
1
remote controller
1
remote controller
button or press
enter into High.
1
enter into High.
enter into High.
remote controller
POWER button to
enter into High
Under High state, press
Under High state, press
Under High state, press
Under high state,
(POWER) button or press
(POWER) button or press
(POWER) button or press
press the POWER
remote controller MODE button
2
remote controller MODE button
remote controller MODE button
2
2
button or press
once to enter into Low.
2
once to enter into Low.
once to enter into Low.
remote controller
MODE button once
to enter into Low
Under Low state, press
Under Low state, press
Under Low state, press
Under Low state,
(POWER) button or press
(POWER) button or press
(POWER) button or press
press the POWER
remote controller MODE button
remote controller MODE button
remote controller MODE button
once to enter into Energy
button or press
3
once to enter into Energy
once to enter into Energy
Saving ECO.
3
remote controller
3
Saving ECO.
Saving ECO.
MODE button once
to enter into Energy
3
saving ECO
Note: The display will continually flash when the unit is in standby mode. Once the unit goes back
into the heat mode the display will stop flashing.
3. Power OFF: Under Energy Saving ECO state, press (POWER) button or press
remote controller (POWER) button once to turn off the machine. All relays
will disclose. Fan stops 15 seconds later, LED displays the remained time of fan
delay. Timing ON can't be set during countdown period.
4. Timing ON/OFF: Under ON/OFF state, press the (TIMER) button (or remote
controller TIMER button) to enter into the timing check interface, LED displays
the remained time and flashes, exit the check interface if it is not operated
within 3 seconds without changing the Set Time; press the
(or remote controller
Time, and refresh the Set Time.
Set Time setting range 0~24h, 1h each time.
Set Time reaches the ON/OFF, buzzer doesn't make sound, enter into
High/OFF mode.
Page 8
Display
Display
Display
Display
button to
button to
button to
or
button) under check state to change the Set
Remarks
Remarks
Remarks
Remarks
1500W Warm air working
1500W warm air working.
1500W warm air working.
1500W warm air working.
900W Warm air working
900W warm air working.
900W warm air working.
900W warm air working.
Environment temperature
Environment temperature
Environment temperature
<set temperature
Operates at 1500W (High) when room
<set temperature
<set temperature
1500W warm air working.
temperature is less than set temperature
1500W warm air working.
1500W warm air working.
Set temperature ≤ environment
Set temperature ≤ environment
Set temperature ≤ environment
temperature ≤ set temperature +3°F
The unit will operate at 900W (Low)
temperature ≤ set temperature +3°F
temperature ≤ set temperature +3°F
900W warm air working.
when the room temperature is 3
900W warm air working.
900W warm air working.
Environment temperature > set
degrees less than the set temperature.
Environment temperature > set
Environment temperature > set
temperature +3°F Stop working,
temperature +3°F Stop working,
temperature +3°F Stop working,
the fan stops 15 seconds later.
The unit will continue to operate until
the fan stops 15 seconds later.
the fan stops 15 seconds later.
the room temperature exceeds the set
temperature by 3 degrees at which point
the unit will stop heating and the fan
will shut down in 15 seconds. The unit
will resume operating once the room
temperature drops more than 3 degrees
below the set temperature.
or
button