AY
9
3V
TP2
RF
0.2Vp-p
1.1Vp-p
0.1Vp-p
1.7Vp-p
C100
DA : 0V
2P
75
ROM : 1.7V
RF2-
DA : 1.7V
C48
74
ROM : 0V
RF-
4P
ROM : 0.8Vp-p
73
DA : 0V
EQ1
DA : 0.8Vp-p
72
ROM : 0V
EQ2
C49
71
1.7Vp-p
RFI
3300P
70
3.3V
ADVDD
1.7V
69
ASY
3.0V
68
0.3V
EFM
67
ADGND
66
TEST0
65
TEST1
64
0V
TEST2
63
TEST3
62
TEST4
61
TESTEN
60
DGND4
59
MD-
58
MD+
57
SD-
56
SD+
55
3.3V/1.7V/0V
TD-
54
TD+
53
FD-
52
FD+
3.3V
51
DVDD4
0V
3.3V
CP16
100K
TP36
LRCK
10
10
SLD-
TP19
M
DM2
NG & SLED
R
Q3
: UMD9N
Q6
: UMD12N
Q7
: DTC124EE
E2
Q8
: 2SB0970
Q9
: DTC114YE
Q10
: DTC114YUA
Q17
: DTA143XUA
G
V1
D2,9
: DA204U
D3
: DAN202U
R
1G
C00
F
F
AZ
TP8
TP75
GND
9
TP76
LD
4
R64
TP77
150
VR
TP78
PD
6
TP79
C+D
C
TP3
F
F
TP80
A
B
TP81
B
A
TP4
E
E
TP82
FCS+
F+
TP83
TRK+
T+
R69
C99
TP84
6.8K
6P
TRK-
T-
TP85
FCS-
F-
R51
C51
3.9K
33P
C18
0.1
TP1
14
ARF
C54
0.01
R55
C55
10K
0.01
CP11
4.7K
CP10
10K
C59 1000P
C60 1000P
C61 1000P
C62 1000P
14
14
SIGNAL LINE
GND LINE
B LINE
BA
CN2
1
VCC
2
VC
2SB1443
3
GND
4
LD
5
VR
DPU1
6
PD
(X92-)
7
C+D
OPTICAL
8
F
PICKUP
9
A
10
B
11
E
12
GND
2SA1774
13
FCS+
2SC4081
14
TRK+
15
TRK-
16
FCS-
DTA124EUA
DTC124EUA
DTC144EUA
UMC2N
DAN202U
CAUTION : For continued safety, replace safety critical components
only with manufacturer's recommended parts (refer to parts list).
Indicates safety critical components. To reduce the risk of electric
shock, leakage-current or resistance measurements shall be carried
out (exposed parts are acceptably insulated from the supply circuit)
before the appliance is returned to the customer.
• DC voltages are as measured with a high impedance voltmeter.
Values may vary slightly due to variations between individual
instruments or/and units.
BB
BC
KDC-MP832U
DAP202U
DA204K
DA204U
M5237ML-CF0J
NJM2100V-ZB
LB1930M-E
TC7SH32FU-F
X32-5830-00 (4/4)