Description

• Advanced high frequency switching design with 92% typical efficiency
• Fully sealed enclosure provides improved reliability in demanding environments
• > 0.98 Power Factor minimizes utility surcharges and maximizes use of AC power
• Approved battery charge algorithms for ideal charging (default I1, I2, U, I3a)
• Memory to store 10 unique algorithms, and tools to load new algorithms in the field
•The internal CPU employs advanced charging management algorithm

Technical Features

DC Output

 
DC Output Voltage - nominal
DC Output Voltage - maximum 34V 51 V 68 V 85V 102V 136V 170V 204V
DC Output Current - maximum 80A 60 A 50 A
Battery Type
Reverse Polarity
Short Circuit

AC Input

AC Input Voltage - range
AC Input Voltage - nominal
AC Input Frequency
AC Input Current - maximum
Current – nominal
AC Power Factor - nominal

Mechanical

Dimensions
Weight
Environmental Enclosure
Operating Temperature
3000W HF/PFC Battery Charger
24XX 36XX 48XX 60XX 72XX 96XX 120XX 144XX
24V 36 V 48 V 60V 72V
90 - 260VAC
120 VAC / 230 VAC
45 - 65 Hz
30A
25 A rms @ 120 VAC / 13 A rms @ 230 VAC
> 0.98
352mm×252mm×168mm
<9.75 kg Standard output cord
IP46
-30°C to +50°C (-86°F to 122°F)
96V 120V 144V
40A 32A
24A
Specific to selected algorithm
Electronic protection – auto-reset
Output closed automatically
1
20A
16A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the pfc3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elcon pfc3000

  • Page 1 3000W HF/PFC Battery Charger Description • Advanced high frequency switching design with 92% typical efficiency • Fully sealed enclosure provides improved reliability in demanding environments • > 0.98 Power Factor minimizes utility surcharges and maximizes use of AC power • Approved battery charge algorithms for ideal charging (default I1, I2, U, I3a) •...
  • Page 2 Storage Temperature -40°C to +85°C (-104°F to 185°F) LED Indicator Red-Green flash (one second interval) Battery Disconnected Red flash (three seconds interval) Repair Battery Red flash (one second interval) <80% Charge Indicator Yellow flash (one second interval) >80% Charge Indicator Green flash (one second interval) 100% Charge Indicator Protection Features...
  • Page 3 curve 3), cut off the power and reconnect it. Alarms LED Flashing Sequence(One Cycle) Indication R G _ _ _ _ _ _ Wrong Battery R G R _ _ _ _ _ Overcharged R G R G _ _ _ _ The temperature of battery is too high R G R G R _ _ _ Incorrect AC Input Voltage...
  • Page 4 rating. 7. Verify that the selected charging curve is suitable for the type of battery to be recharged. 8. In order to avoid voltage drop, the output cables must be as short as possible, and the diameter must be adequate for the output current. 9.

Table of Contents