Technical Features

DC Output

Model
DC Output Voltage - nominal
DC Output Voltage - maximum
DC Output Current – 230vac
DC Output Current – 115vac
Model
DC Output Voltage - nominal
DC Output Voltage - maximum
DC Output Current – 230vac
DC Output Current – 115vac
Battery Type
Reverse Polarity
Short Circuit

AC Input

AC Input Voltage - range
AC Input Voltage - nominal
PFC 5000
5000W HF/PFC Battery Charger
providing
improved reliability in demanding environments
36XX 48XX 60XX 72XX 84XX 96XX
36V
51V
90A
50A
120XX 144XX 156XX 192XX 288XX
120V
170V
37A
15A
90 - 260VAC
115 VAC / 230 VAC
with
92% typical efficiency
48V 60V
72V
68V 85V 102V 119V 136V
87A 75A
62A
38A 30A
26A
144V
156V
192V
204V
221V
272V
30A
27A
22A
13A
12A
10A
Specific to selected algorithm
Electronic protection – auto-reset
Output closed automatically
1
84V
96V
52A
45A
22A
20A
288V
408V
15A
7A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PFC 5000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Elcon PFC 5000

  • Page 1 PFC 5000 5000W HF/PFC Battery Charger Description • Advanced high frequency switching design with 92% typical efficiency • Fully sealed enclosure providing improved reliability in demanding environments • > 0.98 Power Factor minimizes utility surcharges and maximizes use of AC power •...
  • Page 2 AC Input Frequency 45 - 65 Hz AC Input Current - maximum Current – nominal 20 A rms @ 120 VAC / 23 A rms @ 230 VAC AC Power Factor - nominal > 0.98 Mechanical Dimensions 365mm×352mm×139mm Weight < 14kg Standard output cord Environmental Enclosure IP46 Operating Temperature...
  • Page 3 Choice of Charging Curve (curve 1~10) 1.The LED will flash red several times when AC is first connected, then the LED will flash green once. The number of red flashes denotes the present curve. E.g. If the red flashes three times, it means the present curve is curve 3. 2.To choose another curve, cut off the power supply first, then unpeel the label and press the button while connecting the power.
  • Page 4 put the battery charger near any heat sources. Make sure that free space around the charger is sufficient to provide adequate ventilation and easy access to cable sockets. 4. For safety and electromagnetic compatibility the battery charger has a 3-prong plug that will only plug into a properly grounded outlet.

Table of Contents