Only use attachments specified by the manufacturer. • This device contains no user serviceable parts: only refer to authorised, qualified service • personnel for any servicing. Your warranty will be voided if you tamper with the internal components. • BroaMan MUX22 Operating Manual Rev. 2.1...
Leave sufficient space (minimum ½ RU) between the device and any heat emitting devices housed in the same rack. A BroaMan MUX22 may be placed on top or beneath other BroaMan products, without a space between the devices for up to 4 adjacent rack spaces.
Page 5
Disconnection from the mains power supply is only possible by disconnecting the power plug from the mains socket. Eye Safety • This product is a Laser Class 1 product. It complies with IEC 60825-1, FDA 21 CFR 1040.10, and 1040.11. BroaMan MUX22 Operating Manual Rev. 2.1...
Page 6
Such operation can lead to damage of the device’s components due to lack of air-flow through the device. The device may not be serviced, altered or modified without authorization from Broaman or an Broaman authorized distributor / dealer. Only qualified service personnel may carry out repair and maintenance work on the device.
CE/FCC Conformity This document confirms that the product MUX22 bearing the CE (Communauté Européenne) label meets all requirements in the EMC directive 2004/108/EG laid down by the Member States Council for adjustment of legal requirements. Furthermore the product complies with the rules and regulations of the low-voltage directive 2006/95/EG and the Restriction of Hazardous Substances Recast Directive 2011/65/EU (RoHS 2).
Optocore Network. MUX22 can be populated with up to four (in a special version without audio/intercom functionality up to 8) dual channel 3G/HD/SD-SDI modules that can convert electrical to optical or optical to electrical signals.
Front Panel MUX22 IVT/IC444; IVT/IC422; IVT/IC485; IVT/ICAES Word Clock LED: Indicates the selected Sync/Word Clock source: INT: Internal Sync/Word Clock of the device BNC: External via the BNC SYNC input NET: Sync/Word Clock received from the Optocore network Signal Monitor LED for 4 Duplex Audio Channels:...
Page 13
Ethernet communication is established via LAN 1 (rear panel) Ethernet communication is established via LAN 2 (rear panel) Sample rate LED: Yellow: 44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz BroaMan MUX22 Operating Manual Rev. 2.1...
MUX22 IVT/MADI-OPT; IVT/MADI-BNC Word Clock LED: Indicates the selected Sync/Word Clock source: INT: Internal Sync/Word Clock of the device BNC: External via the BNC SYNC input NET: Sync/Word Clock received from the Optocore network Signal Monitor LED for 4 Duplex MADI:...
Page 15
Ethernet communication is established via LAN 1 (rear panel) Ethernet communication is established via LAN 2 (rear panel) Sample rate LED: Yellow: 44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz BroaMan MUX22 Operating Manual Rev. 2.1...
MUX22 IVT Word Clock LED: Indicates the selected Sync/Word Clock source: INT: Internal Sync/Word Clock of the device BNC: External via the BNC SYNC input NET: Sync/Word Clock received from the Optocore network Signal Monitor LED for 8 3G/HD/SDI Channels:...
Page 17
Ethernet communication is established via LAN 1 (rear panel) Ethernet communication is established via LAN 2 (rear panel) Sample rate LED: Yellow: 44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz BroaMan MUX22 Operating Manual Rev. 2.1...
MUX22 IVT/IVT Word Clock LED: Indicates the selected Sync/Word Clock source: INT: Internal Sync/Word Clock of the device BNC: External via the BNC SYNC input NET: Sync/Word Clock received from the Optocore network Signal Monitor LED for 16 3G/HD/SDI Channels:...
Page 19
Ethernet communication is established via LAN 1 (rear panel) Ethernet communication is established via LAN 2 (rear panel) Sample rate LED: Yellow: 44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz BroaMan MUX22 Operating Manual Rev. 2.1...
Rear Panel MUX22 IVT/IC422; IVT/IC485; IVT/ICAES RS485/GPIO: 4 x RS485 (D-Sub-9) or GPIO (D-Sub-15) auxiliary port for data transmission WDM ports LINK1/2: CWDM or DWDM multiplexer Input/Output for Optocore duplex fiber connection (LINK1 and LINK2). Can be used for external fiber devices such as Ethernet switches (see AUX1/2).
MUX22 IVT/IC444 RS485/GPIO: 4 x RS485 (D-Sub-9) or GPIO (D-Sub-15) auxiliary port for data transmission WDM ports LINK1/2: CWDM or DWDM multiplexer Input/Output for Optocore duplex fiber connection (LINK1 and LINK2). Can be used for external fiber devices such as Ethernet switches (see AUX1/2).
MUX22 IVT/MADI-OPT MUX22 IVT/MADI-BNC RS485/GPIO: 4 x RS485 (D-Sub-9) or GPIO (D-Sub-15) auxiliary port for data transmission WDM ports LINK1/2: CWDM or DWDM multiplexer Input/Output for Optocore duplex fiber connection (LINK1 and LINK2). Can be used for external fiber devices such as Ethernet switches (see AUX1/2).
Page 23
(SFP transceiver – type depending on a specyfication) LINK 2: Full-duplex, full bandwidth LC-type optical interface for Optocore transmission (SFP transceiver – type depending on a specyfication) LAN 1: 100 Mbit RJ-45 Ethernet interface LAN 2: 100 Mbit RJ-45 Ethernet interface BroaMan MUX22 Operating Manual Rev. 2.1...
MUX22 IVT MUX22 IVT/IVT RS485/GPIO: 4 x RS485 (D-Sub-9) or GPIO (D-Sub-15) auxiliary port for data transmission WDM ports LINK1/2: CWDM or DWDM multiplexer Input/Output for Optocore duplex fiber connection (LINK1 and LINK2). Can be used for external fiber devices such as Ethernet switches (see AUX1/2).
LAN 1: 100 Mbit RJ-45 Ethernet interface LAN 2: 100 Mbit RJ-45 Ethernet interface MUX22 with RS422 special serial data interface Special serial data RS422 interface is available on request with all Mux22 versions. RS422: 4 x RS422 bi-directional (HD-Sub-26) auxiliary port for data transmission...
BNC-SDI Ports MUX22 can be factory fitted with 0-4 (in a special version up to 8) dual-channel video ports, which are specified at the time of ordering. Each port can be equipped with a high quality BNC connector, providing 3G/HD/SD-SDI connectivity.
The device is equipped with an Optocore FX communication module, which is used for audio and data transport as well as system control of MUX22. The OPTOCORE ® OPTICAL DIGITAL NETWORK SYSTEM utilizes Time Division Multiplex technology (TDM) with a Fiber Channel based 8B10B-NRZI-coding. Static time slots guarantee a synchronous transmission of all channels, at all times, without the use of dynamic bandwidth.
Clock/Bi-Tri-Level Sync signal to networked BroaMan, Optocore or SANE devices. The user can decide whether to lock the BroaMan device and system to the external source or to the internal sync generated in the device. The user can retrieve the Word Clock signal from incoming Video Sync, or regenerate the Sync signal locked with the Word Clock.
(SD, HD or 3G) and the specifications and quality of the cable and connectors. Optical Connections Each MUX22 features internal and external fiber connections. The number of connections depends on the application and will be customized at the time of manufacturing. Each electrical 3G/HD/SD-SDI channel is converted into a different wavelength using internal SFP transceivers and WDM modules.
Below tables list the configurations available as a standard devices with unique ordering code. Please refer to the specific code when ordering. BroaMan offers also custom versions of Mux22 with different I/O number, more fiber AUX channels and special connectivity. To specify custom device please contact inquiry@broaman.com.
MUX22 IVT/IC485 Code Description M224445R515002PA1 Mux22-IVT/IC485 4 x 3G-SDI IN, 4 x 3G-SDI OUT, 4 x RTS 4-wire Intercom, 2 x PSU, 1 x SM Optocore Link, 2 x SANE/LAN/MADI Cat5, 2 x LAN, 4 x RS485/422, 2 PSU, 1 x 1310nm Aux...
8 x 3G-SDI OUT, 4 x Line In, 4 x Line Out, 4 x GPIO, 2 x PSU, 1 x SM Optocore Link, 2 x SANE/LAN/MADI Cat5, 2 x LAN, 4 x GPIO, 2 PSU, 1 x 1310nm Aux MUX22 IVT/ICAES Code Description...
Mux22-IVT/MADI-OPT 8 x 3G-SDI OUT, 4 x duplex fiber MADI, 2 x PSU, 1 x SM Optocore Link, 2 x SANE/LAN/MADI Cat5, 2 x LAN, 4 x GPIO, 2 PSU, 1 x 1310nm Aux MUX22 IVT/MADI-BNC Code Description M2244MCR515002PA1 Mux22-IVT/MADI-BNC...
* Shows the standard pin out for RS485 on the IC485 module. Other pin outs may be specified at the time of order. RJ45 is physically compatible with RJ11 and RJ12 RJ-45 connectors commonly used for RTS/Telex panels and matrices. BroaMan MUX22 Operating Manual Rev. 2.1...
Page 35
D-Sub-37- female Locking system acc. to 4-40 UNC Pin-out Line Level Outputs / General Purpose Outputs (IC444) Line Level Output General Purpose Output Aux. Power +12V D-Sub-37- male Locking system acc. to 4-40 UNC BroaMan MUX22 Operating Manual Rev. 2.1...
Page 36
SANE – Synchronous Audio and Ethernet SANE / SANE / Ethernet Ethernet A device compatible with MADI RX MADI TX 10/100MB Fast Ethernet can be connected to a SANE port for Ethernet data communication. RJ-45 BroaMan MUX22 Operating Manual Rev. 2.1...
Page 37
1, 4, 6 7, 8 D-Sub-9- female Locking system acc. to 4-40 UNC Pin-out USB - Port Channel VBUS USB B – device connector Pin-out DC Input – Factory Fitted Option XLR 4 Pin male BroaMan MUX22 Operating Manual Rev. 2.1...
Page 39
Depending on the configuration of the device, 32VA - Max Security classification Class 1: basic insulation, connected to the protective grounding conductor Security regulations Harmonised European standard EN60065 Mains connector Acc. to IEC-950 Cooling Passive, via surface and ventilation-slits on both sides BroaMan MUX22 Operating Manual Rev. 2.1...
438 mm / 17.25 inch Weight Dependent on the configuration of each specific device. Not more then 3kg. Please note: Modifications that serve the purpose of technical improvement may be carried out without prior notification. BroaMan MUX22 Operating Manual Rev. 2.1...
The warranty will be void if you tamper with internal components. Please address any questions or inquiries to BROAMAN or your distributor/dealer. For a full warranty conditions refer to the Warranty Card attached to every Broaman device with a first shipment. How to Obtain Warranty Service When discovering a problem with an BROAMAN device, you should contact either Broaman directly or a dealer/distributor to determine and confirm a hardware fault.
Package Contents MUX22 is a part of the ordered system. Each MUX22 package should consist of: 1 MUX22 unit • 1 LC-LC 0.25m fibre patch cable • 2 power cables • Any additionally purchased equipment such as optical fiber cables in required lengths, D-Sub cables and adapters, RS232 cables, and international electric cables, which have been supplied on your request and your purchase order, cannot be listed above.
Need help?
Do you have a question about the MUX22 and is the answer not in the manual?
Questions and answers