TSS-Sub800
Parameter
Specification
Protection
Short Circuit Protection
Thermal Protection
DC Offset Protection
Line Fuse Rating
120 VAC
230 VAC
Unit
QA Test Limits
YES
--
Functional
65 deg. C
--
Functional
YES
--
Functional
2.5 Amps
1.25 Amps
Conditions
Direct short at output
@1/8 max unclipped Power
DC present at Speaker Out leads
Type-T or Slo Blo, Fuse markings T2.5A,
250V
Type-T, Low breaking capacity, Fuse
markings T1.25AL, 250V
4
Notes
Temperature rise should not exceed 35K
rise
Relay or crowbar (for driver/fire protection)
External fuse with UL/SEMKO rated holder