Quest Elite 4000 Installation Manual
REQUIREMENTS
Figure 1. Unit Dimensions
Nameplate Data
Model QST ELITE 4000, 115 VAC, 5 amps, 1 phase 60 hertz, 6.34 – 6.41 oz. (180-182g) R-134a refrigerant. Test
press: High side 400 psi (2757.9 kilopascals), (27.6 bar). Low side 88 psi (606.7 kilopascals), (6.1 bar).
Model Quest ELITE 4000, 230 VAC, 2 amps, 1 phase 50 hertz, 6.34 - 6.41 oz. (180-182g) R-134a refrigerant. Test
press: High side 400 psi (2757.9 kilopascals) (27.6 bar). Low side 88 psi (606.7 kilopascals), (6.1 bar).
Model Quest ELITE 4000, 220 VAC, 2 amps, 1 phase 60 hertz, 6.34 - 6.41 oz. (180-182g) R-134a refrigerant. Test
press: High side 400 psi (2757.9 kilopascals) (27.6 bar). Low side 88 psi (606.7 kilopascals), (6.1 bar).
Concentrate Storage
Four 0.8 gallon (3.0 liter) disposable bottles.
NOTE: Refillable Concentrate reservoirs also available.
Figure 2. Concentrate Storage
Recommended Clearance
12" (30.48 cm) on top and 4" (10.16 cm) required in back for air circulation and 4" at the sides of the unit.
Electrical Connection
6 ft. long (1.83 m) power cord with 3-prong plug attached to dispenser. Export models are shipped with a European
plug.
!
CAUTION:
Only trained and certified electrical technicians should replace the power cord or the unit should be returned to an
Authorized Service Center for power cord replacement." The replacement cord must meet all requirements of the
original equipment manufacturer.
FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY, DEATH OR DAMAGE TO THE EQUIPMENT.
© 2010-2016, Cornelius Inc.
- 3 -
Publication Number: 620048956INS