Installing The Control Box (Zone) - Coleman 9330F4552 Installation Instructions Manual

Control kit for heat pump with wall thermostat camper trailer
Table of Contents

Advertisement

1.
Remove the control box assembly's cover which is
held by two sheet metal screws.
2.
Set the "zone" jumper to the proper zone position for
the particular position the air conditioner or heat
pump will be in the coach (Refer to Figure 3 – Zone
1 is shown). Zones should be numbered from the
front of the back of the coach with Zone 1 in front.
3.
Set the "HP"/"NON HP" jumper to "HP" if the unit
is a heat pump or to "NON HP" if the unit is not a
heat pump (Refer to Figure 3 – Non HP is shown).
4.
Feed the field lead wires and ground through the
strain relief found with the control box then through
the 7/8" hole in the side of the box.
FIGURE 3

14. INSTALLING THE CONTROL BOX (ZONE)

5.
Wire nut the black field power conductor to the
stripped black 12-gauge wire in the control box.
6.
Wire nut the white field power conductor to the
stripped white 12-gauge wire in the control box.
7.
Wire nut the ground field power conductor to the
stripped green ground wire in the control box.
8.
Insure that no bare wires can come into contact with
live electrical parts and that wire cannot be pinched
between the control box sides and lid. Insert the
strain relief into the control box entry hole to secure
the field wiring. Reinstall the control box lid.
Attach the thermostat wires to Zone 1 control box per the
illustration below (Refer to Figure 4):
9
FIGURE 4