U-Line CLR1215 Quick Start Manual

1000 series
Hide thumbs Also See for CLR1215:

Advertisement

QUICK START GUIDE
1000 Series
CLR1215
115 V / 60 Hz

Advertisement

Table of Contents
loading

Summary of Contents for U-Line CLR1215

  • Page 1 QUICK START GUIDE 1000 Series CLR1215 115 V / 60 Hz • •...
  • Page 2 1. U-Line Customer Care must be contacted immediately at +1.800.779.2547. 2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
  • Page 3: Table Of Contents

    QUICK START GUIDE u-line.com This Quick Start Guide covers the basics of installation and general use of your product. For more details, see the complete User Guide & Service Manual on u-line.com. Contents Safety and Warning Environmental Requirements Electrical Water Hookup...
  • Page 4: Safety And Warning

    QUICK START GUIDE u-line.com Safety and Warning This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce NOTICE the unit’s ability to reach low temperatures and/or reduce ice production on applicable models. Please read all instructions before installing, operating, or servicing the appliance.
  • Page 5: Electrical

    QUICK START GUIDE u-line.com Electrical Water Hookup PREPARE PLUMBING WARNING The water valve uses a standard 1/4" (6.35 mm) compression fitting. A 10' (3 m) braided flexible water SHOCK HAZARD — Electrical Grounding supply line is included with the unit.
  • Page 6 QUICK START GUIDE u-line.com 3. Locate water CAUTION valve in the front of the unit and Do not use any plastic water supply line. The line thread water is under pressure at all times. Plastic may crack supply line or rupture with age and cause damage to your through.
  • Page 7 The water valve uses a standard 1/4" (6.35 mm) is under pressure at all times. Plastic may crack compression fitting. U-Line recommends using accessory or rupture with age and cause damage to your water hook up kit – part # WATERHOOKUP. The kit home.
  • Page 8 QUICK START GUIDE u-line.com 1. Turn off water supply and disconnect electrical supply 7. Install retaining clip. to product prior to attempting installation. 2. Remove the grille/access panel in the front and the back panel.Locate water valve in the front of the unit...
  • Page 9: Drain

    DRAIN CONNECTION CAUTION With Trap and Vent Proper Drain If your U-Line unit did not come with a factory installed drain pump you must use a gravity A gravity drain may be used if: style drain connection. For assistance in Drain line has at least a 1"...
  • Page 10: Door Swing

    (Optional Hook-Up) requirements for a gravity drain, you may have ordered a pre-installed U-Line P60 drain pump. Waste If you need to install a P60 drain pump into your unit, see Valve DRAIN PUMP section in the User Manual.
  • Page 11: General Installation

    QUICK START GUIDE u-line.com General Installation INSTALLATION 1. Plug in the power/electrical cord. LEVELING INFORMATION 1. Use a level to 2. Gently push the unit into position. Be careful not to confirm the unit is entangle the cord or water and drain lines.
  • Page 12 A adjust panel as necessary. Tighten screws upon robust tape may also completion. be used. U-Line recommends the use of bar clamps to 15.Starting at the corners, re-install the gasket into the Door/Drawer secure the panel to gasket channel in the frame.
  • Page 13: Control Operation

    ”. 3 hours) Clean Mode Hold for five seconds First Use All U-Line controls are preset at the factory. Initial startup ICE CUBE THICKNESS ADJUSTMENT requires no adjustments. NOTICE Ice thickness adjustment should only be made NOTICE one increment at a time. Allow ice maker...
  • Page 14 QUICK START GUIDE u-line.com The ice cube thickness is factory set for best overall Your clear ice machine is pre-set to produce ice between performance. The factory setting is designed to maintain the optimal dimensions illustrated below: an ice bridge of approximately 1/16" to 1/8" (1.6 mm to Cube Details 3.2 mm) under normal conditions, resulting in a dimple of...
  • Page 15: Sabbath Mode

      Sabbath Mode Select Down U-Line Clear Ice Machine models are Star-K certified and can be used during the Sabbath. View a full list of Star-K certified U-Line units at www.star-k.org. To prepare the unit for the Sabbath: 1. Press and hold the until the unit turns off.
  • Page 16: Warranty 1

    One Year Limited Warranty For one year from the date of original purchase, this U-Line product warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase.