Self-diagnosis Function
I Error Indicator
• The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble.
• Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table.
• If more than two troubles occur simultaneously, primarily the highest trouble fo error code is expressed.
• After error occurrence, if error is released, error LED is also released simultaneously.
• To operate again on the occurrence of error code, be sure to turn off the power and then turn on.
• Having or not of error code is different from Model.
Indoor Error
Error code
Description
00
No Error
01
Indoor Room Thermistor Error
02
Indoor In-Piping Error
03
Remote controller Error
04
Drain Pump Error
05
Communication Error between In and Out
06
Indoor Out-Piping Error
Outdoor Error
Error Code
21
DC Peak(IPM Fault)
22
CT2(Max CT)
23
DC Link Low Volt
24
High/Low Pressure/Heatsink Switch
25
Low Voltage / Over Voltage
26
DC COMP Position Error
27
PSC Fault Error
28
DC Link High Volt
32
D-Pipe High(INV)
33
D-Pipe High(Normal)
40
CT Sensor(open/short)
41
INV. D-Pipe Thermistor Error(Open/Short)
44
Outdoor Air Thermistor Error(Open/Short)
45
Cond Pipe Thermistor Error(Open/Short)
46
Suction Pipe Thermistor Error(Open/Short)
47
Const. D-Pipe Thermistor Error(Open/Short)
51
Capcity Error(High/Low)
53
Signal Error(Indoor_Outdoor)
54
Phase Error
60
EEPROM Check Sum Error
61
Cond Pipe High
62
Heatsink High
63
Cond Pipe Low
65
Heatsink Thermistor Error(Open/Short)
Description
MPS
MPS
Variable
Inverter
MPS
MPS
Variable
Inverter
2 times
2 times
2 times
2 times
2 times
2 times
2 times
2 times
3 times
3 times
4 times
4 times
4 times
4 times
4 times
4 times
5 times
5 times
5 times
6 times
6 times
6 times
6 times
6 times
Troubleshooting Guide
LED 1
LED 2
(Red)
(Green)
1 time
2 times
3 times
4 times
5 times
6 times
LED 1
LED 2
(Red)
(Green)
1 time
2 times
3 times
4 times
5 times
6 times
7 times
8 times
2 times
3 times
1 times
4 times
5 times
6 times
7 times
1 times
3 times
4 times
1 times
2 times
3 times
5 times
Service Manual 119
Indoor
Status
ON
OFF
OFF
OFF
OFF
OFF
OFF
Indoor
Status
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents