Information about the installation
Product information
SPLIT is a complete modern heat pump system that offers
effective energy saving and reduced carbon dioxide
emissions.
The heat is retrieved from the outdoor air by an outdoor
module (L8 SPLIT/L12 SPLIT), where the refrigerant, which
circulates in a closed system, transfers the heat from the
heat source (outdoor air) to the indoor module (HM 8-12
SPLIT). This eliminates the need for boreholes and coils in
the ground.

Features of SPLIT

Optimal annual heating factor thanks to the inverter
controlled compressor.
Outdoor unit with compact dimensions.
Speed controlled circulation pump.
Optimized operating costs. The speed of the compressor
is adjusted according to the demand.
Supplemented with the tanks EHZK 90 SPLIT, WWS 300
SPLIT or WWS 500 SPLIT for the indoor module HM 8-12
SPLIT and outdoor module, L8 SPLIT or L12 SPLIT.
Integrated clock for scheduling extra hot water and
temperature lowering/increasing the flow line temper-
ature.
Prepared for control of two climate systems.
Integrated active cooling function.
Possible to connect external heat sources.

Principle of operation SPLIT

System without hot water, only heating (cooling)
RFV SPLIT/
RG10/
RBE SPLIT
RE10
HM 8-12
HBS 16
SPLIT
BT 1
L8 SPLIT /L12
AMS 10-12
SPLIT
Climate system
Klimatsystem
Överströmnings-
Overflow valve
ventil
CP1
HE 30
EHZK 90 SPLIT
Information about the installation
System heating (cooling) and hot water
RFV SPLIT/
RG10/
RE10
RBE SPLIT
HM 8-12
HBS 16
SPLIT
BT 1
L8 SPLIT /L12
AMS 10-12
SPLIT
Function
SPLIT is a system that can produce heating, hot water and
cooling.
The principle during heating can be simplified as follows:
1. The refrigerant in L8 SPLIT/L12 SPLIT retrieves heat
from the outdoor air then compresses it, which in-
creases the temperature further.
2. The hot refrigerant (now in gas state) is routed into
HM 8-12 SPLIT.
3. The refrigerant releases the heat for further distribu-
tion in the system.
4. The refrigerant (now in liquid state) is routed back to
L8 SPLIT/L12 SPLIT and the process is repeated.
By reversing the process, thereby allowing the refrigerant
in L8 SPLIT/L12 SPLIT to retrieve the heat from the water
and release it into the outdoor air, the heat pump can, if
necessary, cool instead.
HM 8-12 SPLIT determines when L8 SPLIT/L12 SPLIT is to
work and not to work, using the collated data from the
temperature sensor. In the event of extra heat demands,
HM 8-12 SPLIT can connect additional heat in the form of
the internal immersion heater, or any connected external
addition.
SPLIT
For Home Owners
Climate system
Klimatsystem
Överströmnings-
Overflow valve
ventil
Required
Erf. säker-
CP1
safety devices
hetsutr.
FQ1
FL1
External additional
Extern tillsats
heat
HEV 300/HEV 500
WWS 300 SPLIT/WWS 500 SPLIT
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents