  • Page 2 © 2014 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. US, Canadian and international patents may apply. Paradox Insight and Paradox are trademarks or registered trademarks of Paradox Security Systems (Bahamas) Ltd. or its affiliates in Canada, the United States and/or other countries.
  • Page 3: Table Of Contents

    HD77 Camera Front Cover Description ........
  • Page 5: Hd77 Camera Front Cover Description

    Chapter 1 Introduction 1.1 Overview The Paradox HD77 camera (‘HD77 camera’) is part of the Paradox Insight™ suite enabling users to manage their security systems from their smartphones. The HD77 camera is a highly reliable HD video and high-quality audio PIR camera with multiple recording functions, delivering unlimited live HD video and audio streaming of events directly to authorized User smartphones and to a Control Monitoring System (CMS).
  • Page 6: Led Status Indicators

    • The PIR indicator can be set On/Off by the installer • The VOD indicator can only be turned-off by the master user using the Paradox Insight™ application. IMPORTANT: Turning the VOD indicator off may be considered a violation of applicable laws in some countries.
  • Page 7: Chapter 2 Installing Hardware

    2.2 Installation Requirements The following hardware is required to install the HD77 camera. • Router • Cables 2.2.1 Router The router must include sufficient ports to connect to: • All HD77 cameras in the system (one port for each camera) Overview Router...
  • Page 8: Wiring

    2.3.1 Wiring the HD77 Camera with a CAT5e Cable Wire the HD77 camera with a single CAT5e or higher cable including two twisted pairs for the 4-wire Combus and two twisted pairs for the Ethernet lines as displayed below. Figure 2.2 – HD77 Camera - CAT5e Cable Wiring...
  • Page 9 Wire the 4-wire Combus cable (A) to the EVOHD control panel and the Ethernet cable (B) to the Ethernet router or switch as displayed below. Figure 2.3 – HD77 Camera - Dual Cable Wiring The following table displays dual cable wiring connectivity.
  • Page 10: Mounting The Hd77

    • Install the HD77 camera on the wall at a height between 2.1m to 2.7m (7ft to 9ft) • Ensure a minimum gap of 2cm (~1 in) between the HD77 camera and the ceiling (to open/close the cover) Figure 2.4 – Mounting Guidelines •...
  • Page 11 • Where exposed to oil vapors or steam • Do not touch the sensor surface or the camera lens as this could result in detector malfunction 2.4.4 Mounting the HD77 Camera on a Swivel Bracket attached to the Wall The swivel bracket features include: •...
  • Page 12 To attach the HD77 camera on the wall with a swivel bracket: Run the cable(s) (2) through the wall plate (1). Secure the flat side of the wall plate to the wall with supplied screws. Run the cables through this hole in the wall plate Figure 2.6 –...
  • Page 13 Pry the front cover apart from the back plate starting from the bottom. Figure 2.10 – HD77 Camera Lock Record the serial number (found on the inner side of the front cover) and location of the of the HD77 Note:...
  • Page 14 Note: Terminal board Figure 2.11 – Wiring the HD77 Camera Terminal Board Mount the HD77 camera back plate (7) on the adaptor plate with a screw through each knock out hole and through the anti-tamper spacer. Knock-out holes Anti-Tamper Spacer Figure 2.12 –...
  • Page 15 2.4.5 Mounting the HD77 Camera on a Wall or Corner To mount the HD77 camera directly on a wall or corner: Separate the front from the back plate of the HD77 camera: a. Open the lock mechanism at the bottom of the device.
  • Page 16 Close and lock the HD77 onto the camera back plate: a. Attach the HD77 camera to the back plate. b. Close the HD77 onto the back plate. c. Close the lock mechanism at the bottom of the HD77 camera (see Figure 2.10 on page 13).
  • Page 17 Power up the system: Connecting the power lines from the 16V AC transformer to a power outlet. The LED3 indicator flashes blue until the boot-up process is complete (boot-up can take up to 3 minutes). Mounting the HD77 Mounting the HD77 Camera on a Wall or Corner...
  • Page 18 Mounting the HD77 Mounting the HD77 Camera on a Wall or Corner...
  • Page 19: Chapter 3 Configuring The Hd77 Camera Settings

    • Registering the HD77 Camera with the IP Receiver on page 38 • Verifying HD77 Camera Functionality on page 38 3.1 Overview Configure the HD77 camera settings with the Paradox BabyWare V 2.8 or higher application (BabyWare). The following workflow describes how to configure the HD77 camera with BabyWare. Update...
  • Page 20 3.2.2 Downloading and Installing the Paradox BabyWare Application To download and install the Paradox BabyWare application: Download the BabyWare application (BabyWare): a. Open the Paradox website: www.paradox.com. b. Login with a username and password provided by Paradox. c. Select the Software field in the left pane. The Software menu opens, displaying available software downloads.
  • Page 21 Configure IP150 settings: a. Select the Additional Info box in the new account Connection window. Figure 3.3 – Accounts Window The Settings window opens displaying the Connection tab settings. b. Select the IP Locator icon Figure 3.4 – Settings Window The Locate IP Device on Network window opens, displaying a list of all IP150 devices.
  • Page 22 The IP Device Configuration window opens. Figure 3.6 – IP Device Configuration Window d. In the DHCP pane: Select the Yes radio button to configure Dynamic IP DHCP Select the No radio button and configure a Static IP address: Fill in the IP Address, Netmask, Gateway and DNS Address settings in the provided fields e.
  • Page 23 Ensure that the HD77 configurations are up-to-date before configuring HD77 camera settings. To update configuration parameters: Stand on the HD77 camera in the Security Module field and double-click or right-click. The Security Module drop-down menu opens. Select the Receive Programming field from the drop-down menu.
  • Page 24 3.2.5 Labeling HD77 Cameras and their Locations Label HD77 cameras and their locations to identify them in the system. To label HD77 cameras and their locations: Open BabyWare. The Home window opens. In the Security Modules field: Locate each device by its serial number and add a Label (for example motion detector with camera) and Location (for example living room) in the provided fields.
  • Page 25: Configuring Hd77 Server Settings

    Figure 3.11 – Accounts Window Navigate to the HD77 camera Programing window: a. Double-click on the required HD77 camera in the Security Modules pane of the Home window (see Figure 3.10 on page 24) OR: Right-click on the HD77 camera> select Programming from the drop-down menu.
  • Page 26 In the Central Monitoring Station pane: Configure Central Monitoring Station parameters received from the Central Monitoring Station in the provided fields. Check the Reporting Enabled box to enable the HD77 to report events to IPRS7 software. 3.3.4 Configuring HD77 Receiver Settings...
  • Page 27 WAN IP, not using PMH or if UPnP is not supported (or fails) in your router. Set a Static IP address for the HD77 camera (either with static LAN IP or by binding a MAC address (recommended)
  • Page 28 When not enabling PMH, acquire a static WAN IP from your ISP. Configure the static IP address settings in the Paradox Insight™ Application and BabyWare application HD77 programming page and ensure that the Poll PMH (ParadoxMyHome) box in the TCP/IP parameters pane of the Programming window is unchecked.
  • Page 29 • Verify that the IP address range leaves at least one IP address available outside of the DHCP range. The static IP address must be outside of the DHCP range. • Record one of the addresses outside the DHCP range as the one you will use for the HD77 camera.
  • Page 30 • Primary DNS • Secondary DNS • IP Address • Gateway • Netmask Test Configurations: Verify the HD77 camera functionality (see Adjusting the HD77 Camera Angle on page 15). 3.4 Configuring PIR Settings This section includes: • Overview on page 30 •...
  • Page 31: Configuring Pir Settings

    Configuring PIR Settings with BabyWare To configure PIR settings in BabyWare: Access HD77 Programming window (see Configuring Server Settings on page 25). Configure the following PIR settings in the PIR Parameters branch of the Programming window: a. Configure PIR LED Display settings: •...
  • Page 32 Test PIR configurations (see Adjusting the HD77 Camera Angle on page 15). 3.4.3 Configuring PIR Settings with the TM50 Touchpad PIR settings can be configured through the TM50 Touchpad. Configure additional HD77 camera settings with BabyWare. Table 1 on page 30 for a description of PIR setting options.
  • Page 33 Select the Advanced field. The Advanced window opens. Figure 3.18 – Menu Select the Installer Programming field. The Installer Code window opens. Figure 3.19 – Advanced Window Key-in the [Installer Code] in the provided field. The Installer Programming window opens. The default installer code is 000000.
  • Page 34 Key-in [4003]. The Module Programing window opens. Figure 3.22 – Installer Programming Window Key-in the HD77 camera [Serial Number] and click Next. The Module Section window opens. The serial number is displayed in BabyWare or on Note: the HD77 back cover.
  • Page 35 Configure PIR Sensitivity Level settings: a. Key-in [002] to open the Module Section [002] window if you have returned to the Module Section window Skip to step b below if the Module Section [002] window is displayed. b. Select the required PIR sensitivity level value between 000-004.
  • Page 36 3.4.4 Configuring PIR Settings with Keypads PIR settings for the HD77 camera can be configured through the K641 series keypads and the K656 keypad. Configure additional HD77 camera settings with BabyWare. See PIR Settings on page 30 for a description of PIR setting options.
  • Page 37 The default installer code is 000000. Note: Key- in [4003]. The Module Programming screen opens. Key-in the HD77 camera Serial Number. The Module Section screen opens. Configure PIR LED Display settings: a. Key-in Section [ The 001 Module Data screen opens.
  • Page 38: Saving Settings

    The configurations are saved. Figure 3.25 – Write Button 3.6 Registering the HD77 Camera with the IP Receiver Register the HD77 camera with the IP receiver (IPRS7 software) after saving initial configurations enabling the camera to report events to the CMS. To register he HD77 camera with the IP Receiver : Select the Register tab from the top menu bar of the Programing window.
  • Page 39 Select the Video tab. Select the Play button. Test functionality: Perform a walk-around in front the HD77 camera view to verify that the HD77 camera records the test, is programmed according to requirements and functioning. Figure 3.27 – Programming Window IMPORTANT: Connect to an external 3G network in order to verify that port forwarding is functioning.
  • Page 40 Verifying HD77 Camera Functionality Configuring PIR Settings with Keypads...
  • Page 41: Chapter 4 Configuring A Paradoxmyhome (Pmh) Account

    Register the HD77 camera with ParadoxMyHome after creating a ParadoxMyHome account. To register the HD77 cameras with ParadoxMyHome: Log-on to BabyWare. Double-click or right-click on the required HD77 camera in the Security Module field of the Home window. Figure 4.1 – Select an HD77 to Register...
  • Page 42 • Site ID: Enter a site name to associate with the HD77 camera Note: • Provide the end-user with the Site ID to enable access to the HD77 camera through the Paradox Insight™ application • Associate up to four HD77 cameras to a Site ID Click OK.
  • Page 43: Deleting A Hd77 Camera From Paradoxmyhome

    Figure 4.4 – Registration Successful Window Verify that the HD77 camera is registered: Log-on to PMH and c heck status, public IP address and ports data. 4.3 Deleting a HD77 Camera from ParadoxMyHome Delete a HD77 camera from PMH in either of the following manners: •...
  • Page 44 Deleting a HD77 Camera from ParadoxMyHome...
  • Page 45: Chapter 5 Upgrading Firmware

    Upgrade HD77 camera firmware with BabyWare V2.8 or higher. To upgrade firmware: Log-on to BabyWare. In the Security Modules pane of the Home window: Double click or right-click on the required HD77 camera. Figure 1 – BabyWare Home Window The Security Modules drop-down menu opens.
  • Page 46 Figure 3 – BabyWare Home Window...
  • Page 47: Appendix A Troubleshooting

    Check the Auto Detect box. Click the Refresh icon Click OK. Verify HD77 camera functionality (see Adjusting the HD77 Camera Angle on page 15). Verify streaming through an external network in order to ensure that port- forwarding functions. Using Note:...
  • Page 48 Confirm that the Port # matches the port number assigned in the router port forwarding. Ensure that the router is correctly connected according to the router manufacturer instructions. Configure IP/Static configurations for the HD77 camera: Figure a. Un-check the DHCP Enabled box in the TCP/IP pane of the Programming window (see on page 20.
  • Page 49 Enter a user name and password (provided by the ISP). d. Bind (Reserve) the Mac address to its IP address for each HD77. e. Assign the port number from the Locate Devices window to forward the IP address port to the HD77 camera.
  • Page 51: Appendix B Specifications

    Appendix B Specifications The following table displays the HD77 camera specifications. Table 1: HD77 Camera Specifications Specification Description Nominal: 12VDC Voltage Input Range 9-16VDC 200 mA without IR illumination LEDs Maximum Current Consumption 330 mA with IR illumination LEDs lit Installation Height 2.1 m - 2.7 m (7 ft - 9 ft)
  • Page 52 Table 1: HD77 Camera Specifications Specification Description See Certifications on page 55 and the Paradox website for the latest Environmental product certifications: http://www.paradox.com/terms/ Operating Temperature -10° C to +40° C (14° F to 104° F)
  • Page 53: Appendix: Cpir Detector Beam Pattern

    Appendix C PIR Detector Beam Pattern The following diagram displays the PIR detector beam pattern. Top view Side view (5.6) (13) (26) (40) Feet (13) 2.1m    (6'8") (6'6") Meters Figure 1 – PIR Detector Beam Pattern EN 50131 testing has been performed for 100 Note: °...
  • Page 55: Appendix D Certifications

    Appendix D Certifications The following table displays the certifications applicable to the HD77 camera. Table 1: Certifications Mark Area/Country Level/Grade/Class European Economic Area (EEA) European Economic Area (EEA) WEEE EN 50131-2-2 Grade 2 Environmental Class II Certification Body: Applica Test...
  • Page 56 However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •...
  • Page 57: Appendix E Reference Guide - Configuring An Ip Router

    Static IP configuration includes setting-up port forwarding and reserving the IP addresses of the IP150 and the HD77camera. Requirement Wire the system IP150 and HD77 camera to the router before configuring the router. Setting Up the Router for Port Forwarding To set up port forwarding: Connect the router according to manufacturer instructions.
  • Page 58 Many routers’ IP address is 192.168.1.1 Enable DHCP: Check the Enable Server radio button in the DHCP Server Configuration pane. If DHCP is not enabled, verify that the IP address range is large enough to accommodate all of HD77 Note: cameras.
  • Page 59 Figure 4 – BabyWare Port Forwarding EXAMPLE: The following example displays IP addresses and ports for 4 HD77 cameras. Table 1: IP Addresses and Port for 4 HD77 Cameras HD77 Camera Name Location IP Address HTTP Port Living room Facing front door 10.0.0.132...
  • Page 60 As each router is different you may need to use the router user manual or search on-line for instructions Note: for your particular router. Figure 5 – Binding or Reserving a Port Router Window Bind the HD77 Camera IP address: a. Right click the HD77 camera. b. Navigate to Communications Settings.
  • Page 61 Figure 7 – Locate Static IP Address on Network Select the IP address with port for your static IP. g. Click Configure h. Click Repeat the process for each HD77 camera.
  • Page 62: List Of Figures

    Screw on HD77 Back Plate to Swivel........
  • Page 63 HD77 Settings Window Update Graphic ........29...
  • Page 64 HD77 Settings ........
  • Page 65 Hardware HD77 Camera Key Features Keypad Programming Table Labeling HD77 Cameras and their Locations Mounting the HD77 Camera on a Wall or Corner PIR Detector Beam Pattern Reference Guide - Configuring an IP Router Registering the HD77 Camera with ParadoxMyHome...
  • Page 66 Setting Up the Router for Port Forwarding Trouble Shooting Updating Configuration Parameters Upgrading Firmware...
  • Page 67: Support Information

    • Please contact your local distributor or: • Contact Paradox • Tel: +1 450 491 7444, Monday to Friday from 8:00 a.m. to 5:00 p.m. EST • Email: support@paradox.com Additional information can be found on our website: www.paradox.com. HD77 Installation Guide EI-02 Printed in Canada...

Table of Contents