Fanned balanced flue gas fired boilers
Hide thumbs Also See for Profile 30e:
Table of Contents

Advertisement

IMPORTANT This appliance must be installed and serviced by a competent person as stated in the Gas Safety (Installation
and Use) Regulations 1994.
Profile boilers are certified for safety, it is therefore important that no external control devices (e.g. flue dampers,
economisers, etc.) be directly connected to these appliances unless covered by these installation instructions or otherwise
recommended in writing. Any direct connection of a control device not approved by Potterton could invalidate the certificate
and the normal warranty.
LIST OF CONTENTS - Page 2

General

Optional Extras

Accessories
Installation Data
Boiler Dimensions
GENERAL - Page 2
Potterton Profile boilers are fully automatically controlled
wall mounted fan powered balanced flue appliances, using
a cast iron heat exchanger and are available in five outputs
ranging from 5.86-23.44kW (20,000-80,000 Btu/h).
The boilers which are designed to provide domestic hot
water and/or central heating must be used on INDIRECT
hot water systems only. The cast iron heat exchangers are
suitable for use on open vented gravity domestic hot
water/pumped central heating systems or fully pumped
systems which may be sealed or open vented.
OPTIONAL EXTRAS - Page 2
The following are kits available as optional extras:—
Internal Fitment Kit, which is suitable for a maximum wall
thickness of 51 0mm (20 in.) is to be used where access to
the outside wall is impracticable.
Pump Cover Kits, located on top of the boiler and
designed to conceal the pump, and/or any motorised valves
installed above the boiler. (Note: Pump cannot be fitted
above the boiler if the vertical flue kit is used).
Terminal Wall Plate, where necessary can be fitted to the
outside wall face to improve the appearance, after making
good around the terminal.
Terminal Guard, to be used when the terminal is fitted less
than 2m above a balcony, above ground or above a flat roof
to which people have access.
Full fitting instructions are provided with each kit.
Supplied By www.heating spares.co Tel. 0161 620 6677
GAD (90/396/EEC)
POTTERTON PROFILE 30e G.C. No. 41 .605.39
POTTERTON PROFILE 40e G.C. No. 41 .605.40
POTTERTON PROFILE 50e G.C. No. 41 .605.41
POTTERTON PROFILE 60e G.C. No. 41 .605.42
POTTERTON PROFILE 80e G.C. No. 41 .605.43
Page No. 2
Page No. 2
Page No. 3
Page No. 3
Page No. 3
Site Requirements
Technical Data
Installation Instructions
Commissioning
Health and Safety Information
Control Systems, Pipework and
Wiring Guide
User's Instructions
All boilers can be supplied with either of the following types
of flue system:
1) Standard horizontal flue system suitable for wall
thickness of 100mm (4 in.) to 510mm (20 in.).
2) 2 metre horizontal flue system which provides a
maximum flue length Of 1955mm (77 in.).
3) Vertical flue system which allows the flue to pass
through a flat roof and terminate at a maximum height
of 1980mm (78 in.) measured from the top of the boiler
case.

P.I.L. PART Nos.

Page No. 3
Page No. 6
Page No. 11
Page No. 18
Back Page
Supplied in
Literature Pack