  • Page 1 User Manual ZIEGLER Multi Analog-Digital Multimeter Printed in India, Subject to change without Notice Genius 04/05/2T...
  • Page 2 RISH Multi 16S DC AC 20.16 AUTO DATA MIN/MAX 19. Servicing - - - When you need service, please contact : - - - - - - - - - - - - TRMS 300 mA 10 A 1000 V fused 1000 V max (8) (9)
  • Page 3: Table Of Contents

    Liquid crystal display (11) Display for the selected function ON/OFF pushbutton (12) Display for the unit of Pushbutton for data hold measured quantity. and MIN/MAX storage functions (13) Over range indication for positive analog range. Pushbutton for manual range (14) Pointer for analog indication. selection (15) Scale for analog indication Multi function pushbutton...
  • Page 4: Introduction

    18.2 Fuses For your safety and for protection of the multimeter, the ZIEGLER Multi A blown fuse is signalled on the LCD display the instant a measured 12S...16S multimeters are tted with an Automatic terminal Blocking quantity having a voltage of more than 4 V is applied to the corresponding System (ABS).
  • Page 5: Switching The Multimeter "On

    Meaning of the symbols on the device Response time (after manual range selection) Warning of a danger point Response time Transient response for Measured quantity/ step function of the (Attention, refer to the user of analog of digital measuring range measured quantity manual) indication...
  • Page 6: Function And Range Selection

    Meter off 4.1 Switching the DC current measuring ranges ON " " DATA + 1 Digit 3 mA for ZIEGLER Multi 12S MIN/MAX + 2 Digit 3 mA and 3 A for ZIEGLER Multi 13S ZIEGLER Multi 14S..16S...
  • Page 7: Liquid Crystal Display

    15 Hz... < 30 Hz 1.0 + 3 ZIEGLER Multi12S/13S 2) except for 30 Hz ... < 45 Hz 0.5 + 3 3) except for ZIEGLER Multi 14S...16S > 65 Hz... 1 kHz 2.0 + 3 3.0 + 3 5. Liquid crystal display Crest.
  • Page 8: Data" Hold Facility

    2) With the exception of the ranges 30 mV and 300 mV. Nominal insulation voltage 1000V according to IEC 348 / DIN VDE 0411 3) 240/280 digits when the ranges 3 mA for RISH Multi 12S/13S and 300 m A, 30 Test voltage 6kV~according to IEC 348/DIN VDE0411 mA, 3 A for RISH Multi 14S...16S are selected according to section4.1.
  • Page 9: Voltage Measurement

    Meteracknowledgement Meas- Measured Display Function DATA Meas. Values uring Sound MIN/MAX MIN/MAX Measuring voltage for resistance measurement Value MINandMAX ranges Signal digital 2 x Short, actual 30 mV/ meas- Stored 300 mV Activate and ured 30 MW F,Hz, % ash Store value 1 x short...
  • Page 10: Withtheks30Measuring Adapter

    Overload Intrinsic error of digital display Capacity Voltagemeasurement +(...% of reading. + ... digits) at reference conditions Overload Overload 22.98 value duration - - - - - - - - - - - - - - - 1.0 + 3 500 V - - - - - - - - - -...
  • Page 11: Current Measurement

    On the 300 mA and 10 A ranges (16 A range for ZIEGLER Multi 13S), an intermittent sound signal warns you, when the measured value exceeds the upper range limit.
  • Page 12: Accurrentmeasurement With(Clip-On)Currenttransf Ormers

    2.0 + 1 sine wave 0.25 + 1 0.1 + 1 5) Continuously 6) ZIEGLER Multi 13S (Without 16 A fuse!) : 16 A continuously, 20 A 5 min ZIEGLER Multi 14S ... 16S: 12 A 5 min, 16 A 30 s...
  • Page 13 Software : MS WINDOWS 3.0 or higher. Resistance measurement Hardware : IBM compatible PC with 1 MB main memory for the WINDOWS version. 2.105 A VGA or EGA monitor. A hard disk with 2 MB free storage space. A 3.5 " disk drive for disks with 1.44 MB storage capacity. A MICROSOFT -compatible mouse If you wish to make hardcopy a printer supported by WINDOWS.
  • Page 14: 1Transformer Output Ma/A

    600 V and ohmic load. Function 15 16 Caution: RISH Multi The measuring ranges 3A and 16 A of ZIEGLER Multi 13S are not protected by a fuse! 30.00 mV 10 mV > 10 GW // < 40 pF 100 mV >...
  • Page 15 15. Temperature measurement point. The capacitance measured at the instant the pushbutton is The RISH Multi 12S...16S allows you to measure temperature with pressed is used as reference value (max.200digits). It is automatically Pt100 and Pt1000 temperature sensors in the range deduced from the values measured thereafter.
  • Page 16: Diode Test And Continuity Test

    The interface packs include the adapters, the necessary connection time, the symbol (18) appears on the LCD. cables and the " ZIEGLER com 100 " data acquisition and evaluation software To switch the buzzer OFF with operating instructions. Briey press the yellow multi-function pushbutton (5) again.