  • Page 1 BREAKFAST CLUB INSTALLATION, USE, AND CARE MANUAL MODEL: TEBC30-C P/N: 19238A 01/17...
  • Page 2 AGLES Breakfast Club. In addition to its Unique Style, Superb Performance and High Quality, this unit is built with pride in the U.S.A. Twin Eagles is committed to making outdoor cooking products you will be proud to own for years.
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION WARNING! Read this manual carefully and completely before using your appliance to ensure proper operation, proper installation, proper servicing and to reduce the risk of fire, burn hazard and/ or other injury. D A N G E R A V E R T I S S E M E N T If you smell gas: S’il y a une odeur de gaz:...
  • Page 4 9. Check flexible hoses for cuts and wear that may affect the safety before each use. 10. Never use the unit in a windy area. 11. The pressure regulator and hose assembly supplied with the Twin Eagles Gas Unit must be used. Replacement pressure regulators and hose assemblies must be those specified by Twin Eagles.
  • Page 5: Table Of Contents

    TABLE OF CONTENTS GETTING STARTED…………………………………………………………………………………………… GAS SAFETY REQUIREMENT........................1 INSTALLATION OF BREAKFAST CLUB.…………................2 ELECTRICAL REQUIREMENTS........................CUT OUT DIMENSIONS FOR BUILT-IN APPLICATIONS..............4 GAS REGULATOR CHECK / CONVERSION....................5 NATURAL GAS CONNECTION…………………………………………………………………………… LIQUID PROPANE GAS CONNECTION....................6 LP GAS CONNECTION……………………………………………………………………………………. LEAK TEST..............................OPERATION............................... Lighting Instructions........................
  • Page 6: Getting Started

    Natural Gas or NG If the Breakfast Club is factory built for natural gas, the regulator supplied is set for 4” water column. No not use any replacement regulator other than that specified by Twin Eagles. Shipment This Breakfast Club is inspected before leaving the factory. The shipping carrier assumes full responsibility for the safe delivery of the appliance.
  • Page 7: L.p. Gas Safety Requirement

    GAS REQUIREMENTS Each appliance is set and tested at the factory for the type of gas supply to be used. Identify the type of gas, either natural gas or LP gas and make sure that the marking on the data plate (rating plate) matches the gas being supplied to the appliance.
  • Page 8: Installation Of Breakfast Club

    INSTALLATION OF BREAKFAST CLUB Safe and satisfactory operation of the Breakfast Club depends upon its proper installation. The installation, adjustments and service of the Breakfast Club must be performed only by a qualified installer and service technician. This is necessary to ensure proper operation and also to prevent accidents. Location When determining a suitable location take into account concerns such as exposure to wind, proximity to traffic paths and keeping any gas supply lines as short as possible.
  • Page 9: Electrical Requirements

    ELECTRICAL REQUIREMENTS The appliance should only be taken apart by a qualified technician, or electrical shock may occur. It is rated at 120V, 60Hz, 450W and 4A. REMINDER: Keep any electrical supply cord and the fuel supply hose away from any heated features. ! WARNING ! Electrical Grounding Instructions: This outdoor gas cooking appliance is equipped with a three prong (grounding) plug for...
  • Page 10: Cut Out Dimensions For Built-In Applications

    WARNING: The Breakfast Club must be installed in a NON-COMBUSTIBLE ENCLOSURE ONLY. Twin Eagles Breakfast Club is ETL – approved for residential installation. Cutout must include a 4” (10.2cm) x 4” (10.2cm) opening for a side or bottom gas connection in two locations. The openings are indicated by the square, dashed cut outs in the diagram above.
  • Page 11: Gas Regulator Check / Conversion

    GAS REGULATOR CHECK / CONVERSION If the side burner is factory built for natural gas, the regulator supplied is set for 4” water column. The regulator is convertible to 11” water column for system LP application. Do not use with a 20-lb LP cylinder. Make sure that the regulator is set for the correct gas type.
  • Page 12: Natural Gas Connection

    NATURAL GAS CONNECTION CAUTION: PROVIDE ADEQUATE VENTILATION HOLES IN THE ENCLOSURE FOR SAFETY PURPOSES IN THE EVENT OF GAS LEAK. The regulator supplied is set for 4” water column and is for use with Natural gas only. • The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
  • Page 13: Liquid Propane Gas Connection

    11” WC and is for use with L.P. gas only. The factory-supplied regulator and hose must be used with a 20 lb. L.P. cylinder. For plumb-in installation (system L.P. installation), the regulator must be changed and a main gas shutoff valve must be installed. Contact your Twin Eagles dealer for a system L.P. regulator. ! WARNING ! The gas supply hose should be inspected prior to each use.
  • Page 14: Lp Gas Connection

    LP GAS CONNECTION Procedure for LP Gas Cylinder Connection (20 lbs.) 1. Turn Hand Wheel on cylinder clockwise until it stops to ensure the Cylinder Valve is fully closed. 2. Turn all of the burner knobs to the OFF position. 3.
  • Page 15: Leak Test

     Check to ensure that flexible hoses do not have any cuts and wear that may affect the safety before each use. Only the factory supplied hose and regulator must be used. Use only replacement regulator and hose assemblies specified by Twin Eagles. LEAK TEST 1) Prepare a leak testing solution of sudsy water by mixing in a spray bottle with half liquid soap and half water.
  • Page 16: Lighting Instructions

    OPERATING INSTRUCTONS BEFORE LIGHTING THE UNIT: • DO NOT ATTEMPT TO LIGHT THE BREAKFAST CLUB IF YOU SMELL GAS. • WARNING! IT IS CRITICAL THAT THE GAS BURNERS ARE PROPERLY INSTALLED. If not properly installed, gas may leak outside of the burner that could lead to fire, potential damage to your appliance and bodily injury.
  • Page 17: Manual Lighting Instructions

    Manual Lighting Instructions (Top Burner Only) If the electronic ignition does not light the top burner, the burner can be lit manually using a long match (or taper). 1. Remove the cover from the top burner. 2. Ensure the Gas Supply Cylinder Valve is closed and the burner knob is set to the off position. 3.
  • Page 18: Cleaning And Maintenance

    TWIN EAGLES products have been tested in saline solutions, highly chlorinated solutions and have been tested against exposure to highly acidic foods. The test results proved the type 304 stainless steel can withstand exposure over prolonged periods of time.
  • Page 19: Grease Tray

    WARNING: It is recommended that your TWIN EAGLES products be kept dry and covered when not in use. This is even more important when long-term storage is intended. If you are located along the coast or in the desert, wind driven sand is extremely abrasive and can pit and scratch the stainless steel.
  • Page 20: Spider And Insect Warning

    Spider and Insect Warning Spiders and other insects can nest in the burners and orifices of this and any other outdoor products, which causes the gas to flow from the front of the burner. This can create a dangerous condition that can cause a fire behind the valve panel, damaging the Breakfast Club and making it unsafe to operate.
  • Page 21: Exploded View

    EXPLODED VIEW...
  • Page 22 Griddle Plate Bezel Housing S16365 110V Switch S16196 12V Switch, Illuminated, 19mm, Blue S15312 Thermostat S16113 Pilot Light, Red S13203 Twin Eagles Emblem S12710 Manifold S12603 Elbow, Mixer 375cc S15149YSB Valve Burner, TEBC S26361WY Front Panel Welded Assembly S16272 Battery Pack...
  • Page 23: Wiring Diagram

    WIRING DIAGRAM...
  • Page 24 2206. Be prepared to furnish the following information: Purchaser’s name, model and serial number of the grill, date of purchase and the accurate description of the problem. Twin Eagles will not pay for service calls for correcting an installation problem. Owner shall be responsible for proper installation, providing normal care and maintenance, providing proof of purchase upon request and making the grill accessible for service.
  • Page 25: Warranty Registration

    HOW TO OBTAIN SERVICE For service, please contact your TWIN EAGLES dealer or call TWIN EAGLES direct at (800) 789-2206 or (562) 802-3488 or fax (562) 802-3391 Mailing address: Twin Eagles, Inc. 13259 East 166 Street Cerritos, CA 90703 Visit us at http://twineaglesgrills.com/...