Kenwood TK-385 Service Manual page 28

Hide thumbs Also See for TK-385:
Table of Contents

Advertisement

TK-385
Transmitter Section [Panel Tuning Mode except when Panel TEST Mode is specified.]
Item
Condition
7. DQT Balance 1) Adj item [BAL]
Adjust
Adjust [∗∗∗]
LPF:3kHz
HPF:OFF
2) Adj item
[L BAL]
Adjust [∗∗∗]
PTT:ON
8. Max DEV
1) Adj item [MAX]
Adjust
Adjust [∗∗∗]
AG:1kHz / 80mV
Dev meter filter
LPF:15kHz
HPF:OFF
2) Adj item
[L MAX]
Adjust [∗∗∗]
PTT:ON
9. MIC
[Panel Test Mode]
Sensitivity
1) CH-Sig: 1-1
Check
AG:1kHz / 8mV
LPF:15kHz
PTT:ON
10.QT Deviation 1) Adj item [QT]
Adjust
Adjust [∗∗∗]
LPF:3kHz
HPF:OFF
2) Adj item
[L QT]
Adjust [∗∗∗]
PTT:ON
11.DQT
1) Adj item [DQT]
Devition
Adjust [∗∗∗]
Adjust
LPF:3kHz
HPF:OFF
2) Adj item
[L DQT]
Adjust [∗∗∗]
PTT:ON
12.DTMF
1) Adj item [DTMF]
Deviation
Adjust [∗∗∗]
Adjust
LPF:15kHz
HPF:OFF
PTT:ON
13.FFSK
1) Adj item [FFSK]
Deviation
Adjust [∗∗∗]
Adjust
LPF:15kHz
HPF:OFF
PTT:ON
28
ADJUSTMENT
Test equipment
Power meter
Dev meter
Oscilloscope
AG
AF VTVM
[C BAL]
[H BAL]
[C MAX]
[H MAX]
[C QT]
[H QT]
[C DQT]
[H DQT]
Measurement
Unit
Terminal
Unit
Panel
ANT
Panel
universal
connector
Panel
ANT
Panel
universal
connector
Adjustment
Specifications/
Remark
Parts
Method
Encoder
Make the
knob
demodulation
waves into
square waves.
±50Hz
1.85kHz
(According to
the larger +,-)
Check
1.2~2.0kHz
±50Hz
Encoder
0.35kHz
knob
±0.05kHz
1.45kHz
±0.05kHz
1.45kHz