EMR BDAMON02-NFPA72 User Manual

Bi-directional power amplifier monitor

Advertisement

Quick Links

EMR CORPORATION
th
17431 N. 25
Avenue - Phoenix, Arizona 85023
Phone: (623) 581-2875 - Toll Free: (800) 796-2875 - Fax: (623) 582-9499
info@emrcorp.com – www.emrcorp.com
Bi-Directional Power Amplifier Monitor
USERS MANUAL
USERS MANUAL
Rev. 6
Rev. 6
BDAMON02-NFPA72

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BDAMON02-NFPA72 and is the answer not in the manual?

Questions and answers

Summary of Contents for EMR BDAMON02-NFPA72

  • Page 1 BDAMON02-NFPA72 Bi-Directional Power Amplifier Monitor USERS MANUAL USERS MANUAL Rev. 6 Rev. 6 EMR CORPORATION 17431 N. 25 Avenue - Phoenix, Arizona 85023 Phone: (623) 581-2875 - Toll Free: (800) 796-2875 - Fax: (623) 582-9499 info@emrcorp.com – www.emrcorp.com...
  • Page 2: Table Of Contents

    ................BDAMON02-SNMP Manual – Rev. 6 © 2016 EMR Corporation...
  • Page 3 The EMR BDA Monitor (Model #BDAMON02-NFPA72) is a microprocessor-controlled unit capable of monitoring the Primary AC, Power Supply/Battery DC Voltage, and the DC Current for up to four RF amplifiers used in any EMR Signal Enhancement System. BDA monitoring features vary depending on the relevant hardware configuration. This documentation covers features and settings which are common to most users.
  • Page 4: Physical Connectivity

    BDAMON02-NFPA72 USERS MANUAL Physical Connectivity The BDAMON02-NFPA72 is available as a pre-installed component of an EMR Bi-Directional Amplifier (BDA) system. When the BDA system is plugged into a reliable power source the power indicators on the monitor unit will light/glow.
  • Page 5: Web Interface Access

    The home page will refresh automatically approximately every 10-15 seconds. Select Clear Alarm(s) button to reset the alarm statuses (must be logged in). The reset button on the front of the unit also resets the alarm statuses. BDAMON02-NFPA72 Manual © 2016 EMR Corporation...
  • Page 6: Alarm Setup

    Alarms can be reset via the web page or the Reset button on the front panel of the monitoring unit. The reset procedure will clear active alarms. The Hysteresis field determines how long a failed condition persists before the alarm is tripped. BDAMON02-NPA72 Manual © 2016 EMR Corporation...
  • Page 7: Ip Setup Menu

    Static settings are configurable here once DHCP has been disabled. CAUTION: Inputting incorrect static IP settings will make the web page inaccessible requiring a factory reset to regain access the webpage (see Factory Reset, page 8). BDAMON02-NFPA72 Manual © 2016 EMR Corporation...
  • Page 8: Dns Server Setup

    Changes input desired Static DNS settings and click Save Changes again. Email Setup The BDA Monitor can send alarm messages to up to 5 separate configured email addresses. Email alarm recipients are selectable on the Alarm Setup page. BDAMON02-NPA72 Manual © 2016 EMR Corporation...
  • Page 9: Date & Time

    BDAMON02-NFPA72 USERS MANUAL Date & Time The BDAMON02-NFPA72 is configured to automatically synchronize with NIST internet time servers. Select the Time Zone GMT differential specific to the time zone of your location. Misc. Setup Misc. Setup (miscellaneous settings) contains unit settings including Unit Name, Home Page Refresh Rate, SNMP Trap and Password Reset.
  • Page 10: Password Reset

    Obtaining the MIB File The MIB file for SNMP Trap is provided, and additional information on SNMP setup is available for download from the EMR website at: http://emrcorp.com/downloads/BDAMON/ Factory Reset To reset the unit to factory default settings, remove power from the unit, press and hold the Reset button on the front of the unit while reapplying power to the unit.
  • Page 11: Appendix

    This application note describes the installation of the Antenna/Line Monitor Unit (ALMU) to an EMR Bi-Directional Amplifier (BDA). One ALMU is required for each antenna port of the BDA, therefore two ALMU are supplied. Each ALMU unit is marked for either the Uplink or Downlink antenna port of the BDA.
  • Page 12 (2) Signal Booster Failure (3) Battery Charger Failure (4) Low-battery capacity (5) Power Supply Failure (6) Antenna Malfunction (7) Signal Booster Trouble Note: Signal Booster trouble (any alarm) closes on any alarm except the door alarm. BDAMON02-NPA72 Manual © 2016 EMR Corporation...
  • Page 13 BDAMON02-NFPA72 USERS MANUAL BDAMON02-NFPA72 Manual © 2016 EMR Corporation...
  • Page 14 Pin 21 = Signal Booster Trouble Alarm Common Pin 22 = Signal Booster Trouble Alarm Normally Open Pin 23 = Signal Booster Trouble Alarm Normally Closed Pin 24 = Spare Pin 25 = Ground BDAMON02-NFPA72 Manual © 2016 EMR Corporation...
  • Page 15 17431 N. 25th Avenue – Phoenix, Arizona 85027 Tel: (623) 581-2875 – Toll Free: (800) 796-2875 – Fax: (623) 582-9499 www.emrcorp.com – info@emrcorp.com...