Abnormal
High Voltage Circuit Broken
screen
No Picture
Next parts will be broken, Vbw line
on Scan Board, Vsw line on
Common Board, (High Voltage
Board).
CHECK POINT
fuse on board, Vbw or Vsw line on
board.
11
REWORK
Change the scan or common
board (High voltage board).