Download Print this page
UPM RCT100 Owner's Manual

UPM RCT100 Owner's Manual

Programmable timer with wireless photocell transmitter

Advertisement

Available languages

Available languages

Quick Links

http://waterheatertimer.org/UPM-timers-and-manuals.html
RCT100 + RT601
Programmable
Wireless Photocell Transmitter
Congratulations on your
purchase of a UPM remote
control product. Please
take the time to read and
understand this manual so
you can begin to enjoy the
convenience and energy
saving benefits this product
has to offer.
RESET
PROGRAMMABLE TIMER
ON/OFF
RANDOM
CD
!
20 ON/OFF settings
!

Countdown timer

PROGRAM
SET
!
3 random functions
LEARN
!
12/24 hour clock
!
15A, 1800W (resistive)
PHOTOCELL TRANSMITTER
!
433 M z RF technology
!
Activates timer at dusk
!
Timing Control Dial -
(30mins, 1, 2, 4, 6, 8,
10hrs, or continuous
!
Brightness Dial - for light
sensitivity adjustment
Programmable Timer
!
Transmission range: up
to 40m in open area
PAGE 1
TIMER OPERATION

setting the clock

1
Go to
using
CLOCK
2
Press SET
3
Day select with
1
4
Press SET
5
ON/OFF
Hour select with
SET
6
Press SET
Press SET
7
2 4 6 810
Minute select with
Minute select with
8
Press SET
9
Second select with
10
Press SET
To toggle between 12/24 hour format, press RANDOM during
clock setting.
To activate/deactivate Daylight Saving Time (DST) function, press
and hold both
and
together for 3 seconds in
solid
for DST.
PAGE 7
GETTING STARTED
remove the battery cover from
1
Timer with
the back of the timer
place two button cell batteries
2
between terminals observing
proper polarity then replace cover
remove the battery cover from
1
the transmitter
place two AA size batteries into
2
compartment observing proper
polarity then replace cover
3
COUNTDOWN
ON/OFF
SET
PROGRAM
Photocell Transmitter
PROGRAM SETTINGS
1
2
Press SET
3
Day select with
4
Press SET
5
Hour select with
RESET
CD
RANDOM
6
Press SET
PROGRAM
7
3 5 7 9
Minute select with
8
Press SET
For
single disable
1
F
or
master disable
2
Press SET
3
Press ON/OFF to disable (
Press SET 3 times to exit (single disable)
4
OR press SET 4 times to exit (master)
CLOCK
mode;
Repeat steps
battery installation
1
1
button descriptions
RESET
LED INDICATOR
RANDOM
PHOTOCELL
RESET
ON/OFF
CD
RANDOM
SET
PROGRAM
LEARN
TIMING CONTROL DIAL
RF "TRANSMIT" BUTTON
NEW CODE BUTTON
MODE SWITCH
BRIGHTNESS DIAL
PAGE 2
Program select with
RESET
ON/OFF
RANDOM
CD
2 4 6 8
PROGRAM
SET
Programs are arranged in a circular pattern
with the clock and countdown functions:
Program 1-20
CLOCK
disable program/master disable
select PROGRAM with
go to
CLOCK
using
3
X
)
ON/OFF
SET
2
4
1
4
to
to undo disable
( X
)
PAGE 8
PHOTOCELL TRANSMITTER
2
Once you insert batteries into the transmitter, you will automatically enter
1
the user setting mode. This mode will last for two minutes in which you
can easily adjust the brightness or light sensitivity of the photocell sensor.
Alternately, you can press the RF button on the transmitter to enter the
user setting mode.
2
In user setting mode, turn the BRIGHTNESS DIAL to adjust the light
2
sensitivity of the photocell sensor.
Use the LED INDICATOR (on front of transmitter) as a reference, so that
*
you can fine tune the light sensitivity as desired.
The LED INDICATOR of the transmitter will:
> TURN ON - when the photocell sensor detects that it is bright
> TURN OFF - when the photocell sensor detects that it is dark
COUNTDOWN TIMER
The to-the-second countdown feature of this timer starts from the ON or OFF
position and counts down to zero when activated.
1
1
3 5 7
2
Press SET
3
Start ON or OFF select with
4
Press SET
CD
5
Hour select with
6
Press SET
7
Minute select with
8
Press SET
9
1
Second select with
RESET
CD
RANDOM
PROGRAM
10
Press SET
Press CD to start the countdown function
Stop countdown timer function with CD or ON/OFF
user setting mode
*
1
2
PAGE 3
Press
once from
1
RESET
ON/OFF
CD
RANDOM
SET
PROGRAM
3 5 7 9
2 4 6 810
PAGE 9

Advertisement

loading

Summary of Contents for UPM RCT100

  • Page 1: Countdown Timer

    Congratulations on your proper polarity then replace cover purchase of a UPM remote control product. Please Alternately, you can press the RF button on the transmitter to enter the take the time to read and user setting mode.
  • Page 2 In order to maintain compliance with FCC regulations, shielded cables must Solid for programmable Programmable Timer RCT100 be used with this equipment. Operation with non-approved equipment or Ratings: 120V AC, 15A unshielded cables is likely to result in interference to radio and TV reception.
  • Page 3 COMMEN T DÉMARRER ÉMETTEUR À PHOTOCELLULE Emplacements RCT100 + RT601 des touches Mode de réglage de l'utilisateur enlever le couvercle du compartiment Minuterie programmable avec des piles au dos de la minuterie Une fois les piles insérées, on est automatiquement en mode réglage de émetteur à...
  • Page 4 Aléatoire solide est programmable câbles armés avec ce matériel, sans quoi il y aura probablement un Minuterie Programmable RCT100 Commande: 120V AC, 15A brouillage de la réception de programmes de télévision ou de radio. * La fonction aléatoire programmable ne fonctionne qu'avec le Charge maximum: 1800W résistant;...

This manual is also suitable for:

Rt601